📄 frsld-mib
字号:
frsldPvcSmplDataDeliveredC OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets that were received at frsldPvcCtrlReceiveRP and determined to have been sent within CIR during this interval. If it is the case that the high capacity counters are also used, this MUST report the value of the lower 32 bits of the CounterBasedGauge64 value of frsldPvcSmplHCDataDeliveredC." REFERENCE "FRF.13: Section 5.1 (DataDeliveredc)" ::= { frsldPvcSampleEntry 10 } frsldPvcSmplDataDeliveredE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets that were received at frsldPvcCtrlDeliveredRP and determined to have been sent in excess of the CIR during this interval. If it is the case that the high capacity counters are also used, this MUST report the value of the lower 32 bits of the CounterBasedGauge64 value of frsldPvcSmplHCDataDeliveredE." REFERENCE "FRF.13: Section 5.1 (DataDeliverede)" ::= { frsldPvcSampleEntry 11 } frsldPvcSmplDataOfferedC OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets that were offered through frsldPvcCtrlTransmitRP within CIR during this interval. If it is the case that the high capacity counters are also used, this MUST report the value of the lower 32 bits of the CounterBasedGauge64 value of frsldPvcSmplHCDataOfferredC." REFERENCE "FRF.13: Section 5.1 (DataOfferedc)" ::= { frsldPvcSampleEntry 12 } frsldPvcSmplDataOfferedE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets that were offered through frsldPvcCtrlTransmitRP in excess of the CIR during this interval. If it is the case that the high capacity counters are also used, this MUST report the value of the lower 32 bits of the CounterBasedGauge64 value of frsldPvcSmplHCDataOfferedE." REFERENCE "FRF.13: Section 5.1 (DataOfferede)" ::= { frsldPvcSampleEntry 13 } frsldPvcSmplHCFrDeliveredC OBJECT-TYPE SYNTAX CounterBasedGauge64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames that were received at frsldPvcCtrlReceiveRP and determined to have been sent within CIR during this interval. This object is a 64-bit version of frsldPvcSmplFrDeliveredC." REFERENCE "FRF.13: Section 4.1 (FramesDeliveredc)" ::= { frsldPvcSampleEntry 14 } frsldPvcSmplHCFrDeliveredE OBJECT-TYPE SYNTAX CounterBasedGauge64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames that were received at frsldPvcCtrlReceiveRP and determined to have been sent in excess of the CIR during this interval. This object is a 64-bit version of frsldPvcSmpl- FrDeliveredE." REFERENCE "FRF.13: Section 4.1 (FramesDeliverede)" ::= { frsldPvcSampleEntry 15 } frsldPvcSmplHCFrOfferedC OBJECT-TYPE SYNTAX CounterBasedGauge64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames that were offered through frsldPvcCtrlTransmitRP within CIR during this interval. This object is a 64-bit version of frsldPvcSmplFrOfferedC." REFERENCE "FRF.13: Section 4.1 (FramesOfferedc)" ::= { frsldPvcSampleEntry 16 } frsldPvcSmplHCFrOfferedE OBJECT-TYPE SYNTAX CounterBasedGauge64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames that were offered through frsldPvcCtrlTransmitRP in excess of the CIR during this interval. This object is a 64-bit version of frsldPvcSmplFrOfferedE." REFERENCE "FRF.13: Section 4.1 (FramesOfferede)" ::= { frsldPvcSampleEntry 17 } frsldPvcSmplHCDataDeliveredC OBJECT-TYPE SYNTAX CounterBasedGauge64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets that were received at frsldPvcCtrlReceiveRP and determined to have been sent within CIR during this interval. This value is a 64-bit version of frsldPvcSmplDataDeliveredC." REFERENCE "FRF.13: Section 5.1 (DataDeliveredc)" ::= { frsldPvcSampleEntry 18 } frsldPvcSmplHCDataDeliveredE OBJECT-TYPE SYNTAX CounterBasedGauge64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets that were received at frsldPvcCtrlReceiveRP and determined to have been sent in excess of the CIR during this interval. This value is a 64-bit version of frsldPvcSmplData- DeliveredE." REFERENCE "FRF.13: Section 5.1 (DataDeliverede)" ::= { frsldPvcSampleEntry 19 } frsldPvcSmplHCDataOfferedC OBJECT-TYPE SYNTAX CounterBasedGauge64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets that were offered through frsldPvcCtrlTransmitRP within CIR during this interval. This value is a 64-bit version of frsldPvcSmplDataOfferedC." REFERENCE "FRF.13: Section 5.1 (DataOfferedc)" ::= { frsldPvcSampleEntry 20 } frsldPvcSmplHCDataOfferedE OBJECT-TYPE SYNTAX CounterBasedGauge64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets that were offered through frsldPvcCtrlTransmitRP in excess of the CIR during this interval. This object is a 64-bit version of frsldPvcSmplDataOfferedE." REFERENCE "FRF.13: Section 5.1 (DataOfferede)" ::= { frsldPvcSampleEntry 21 } frsldPvcSmplUnavailableTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of time this PVC was declared unavailable for any reason during this interval." REFERENCE "FRF.13: Section 6.1 (OutageTime)" ::= { frsldPvcSampleEntry 22 } frsldPvcSmplUnavailables OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times this PVC was declared unavailable for any reason during this interval." REFERENCE "FRF.13: Section 6.1 (OutageCount)" ::= { frsldPvcSampleEntry 23 } frsldPvcSmplStartTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime when this sample interval started." ::= { frsldPvcSampleEntry 24 } frsldPvcSmplEndTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime when this sample interval ended. No data will be reported and the row will not appear in the table until the sample has been collected." ::= { frsldPvcSampleEntry 25 } -- Capabilities Group -- This group provides capabilities objects for the tables -- that control configuration. frsldPvcCtrlWriteCaps OBJECT-TYPE SYNTAX BITS { frsldPvcCtrlStatus(0), frsldPvcCtrlPacketFreq(1), frsldPvcCtrlDelayFrSize(2), frsldPvcCtrlDelayType(3), frsldPvcCtrlDelayTimeOut(4), frsldPvcCtrlPurge(5), frsldPvcCtrlDeleteOnPurge(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the write capabilities for the read-create objects of the PVC Control table. If the corresponding bit is enabled (1), the agent supports writes to that object." ::= { frsldCapabilities 1 } frsldSmplCtrlWriteCaps OBJECT-TYPE SYNTAX BITS { frsldSmplCtrlStatus(0), frsldSmplCtrlBuckets(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the write capabilities for the read-create objects of the Sample Control table. If the corresponding bit is enabled (1), the agent supports writes to that object." ::= { frsldCapabilities 2 } frsldRPCaps OBJECT-TYPE SYNTAX BITS { srcLocalRP(0), ingTxLocalRP(1), tpTxLocalRP(2), eqiTxLocalRP(3), eqoTxLocalRP(4), otherTxLocalRP(5), srcRemoteRP(6), ingTxRemoteRP(7), tpTxRemoteRP(8), eqiTxRemoteRP(9), eqoTxRemoteRP(10), otherTxRemoteRP(11), desLocalRP(12), ingRxLocalRP(13), tpRxLocalRP(14), eqiRxLocalRP(15), eqoRxLocalRP(16), otherRxLocalRP(17), desRemoteRP(18), ingRxRemoteRP(19), tpRxRemoteRP(20), eqiRxRemoteRP(21), eqoRxRemoteRP(22), otherRxRemoteRP(23) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the reference points that the agent supports. This object allows the management application to discover which rows can be created on a specific device." ::= { frsldCapabilities 3 } frsldMaxPvcCtrls OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum number of control rows that can be created in frsldPvcCtrlTable. Sets to this object lower than the current value of frsldNumPvcCtrls should result in inconsistentValue." ::= { frsldCapabilities 4 } frsldNumPvcCtrls OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current number of rows in frsldPvcCtrlTable." ::= { frsldCapabilities 5 } frsldMaxSmplCtrls OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum number of control rows that can be created in frsldSmplCtrlTable. Sets to this object lower than the current value of frsldNumSmplCtrls should result in inconsistentValue." ::= { frsldCapabilities 6 } frsldNumSmplCtrls OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current number of rows in frsldSmplCtrlTable." ::= { frsldCapabilities 7 } -- Conformance Information frsldMIBGroups OBJECT IDENTIFIER ::= { frsldConformance 1 } frsldMIBCompliances OBJECT IDENTIFIER ::= { frsldConformance 2 } -- -- Compliance Statements -- frsldCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMP entities which support with Frame Relay Service Level Definitions. This group defines the minimum level of support required for compliance." MODULE -- this module MANDATORY-GROUPS { frsldPvcReqCtrlGroup, frsldPvcReqDataGroup, frsldCapabilitiesGroup}
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -