📄 atm2-mib
字号:
DESCRIPTION "This table contains ATM local interface configuration parameters, one entry per ATM signalling interface." ::= { atm2MIBObjects 4 }atmSigSupportEntry OBJECT-TYPE SYNTAX AtmSigSupportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This list contains signalling configuration parameters and state variables." INDEX { ifIndex } ::= { atmSigSupportTable 1}AtmSigSupportEntry ::= SEQUENCE { atmSigSupportClgPtyNumDel INTEGER, atmSigSupportClgPtySubAddr INTEGER, atmSigSupportCldPtySubAddr INTEGER, atmSigSupportHiLyrInfo INTEGER, atmSigSupportLoLyrInfo INTEGER, atmSigSupportBlliRepeatInd INTEGER, atmSigSupportAALInfo INTEGER, atmSigSupportPrefCarrier OCTET STRING}atmSigSupportClgPtyNumDel OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether the Calling Party Number Information Element is transferred to the called party address. The value of this object can be: - enabled(1) This Information Element is transferred to the called party - disabled(2) This Information Element is NOT transferred to the called party." ::= { atmSigSupportEntry 1 }atmSigSupportClgPtySubAddr OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether to accept and transfer the Calling Party Subaddress Information Element from the calling party to the called party. Calling party subaddress information shall only be transferred to the called party if calling party number delivery is enabled (i.e., atmSigSupportClgPtyNumDel = 'enabled(1)'. The value of this object can be: - enabled(1) This Information Element is transferred to the called party - disabled(2) This Information Element is NOT transferred to the called party." ::= { atmSigSupportEntry 2 }atmSigSupportCldPtySubAddr OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether to accept, transfer, and deliver the Called Party Subaddress Information Element from the calling party to the called party. The value of this object can be: - enabled(1) This Information Element is transferred to the called party - disabled(2) This Information Element is NOT transferred to the called party." ::= { atmSigSupportEntry 3 }atmSigSupportHiLyrInfo OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether to accept, transfer, and deliver the Broadband High Layer Information Element from the calling party to the called party. The value of this object can be: - enabled(1) This Information Element is transferred to the called party - disabled(2) This Information Element is NOT transferred to the called party." ::= { atmSigSupportEntry 4 }atmSigSupportLoLyrInfo OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether to accept, transfer, and deliver the Broadband Low Layer Information Element from the calling party to the called party. The value of this object can be: - enabled(1) This Information Element is transferred to the called party - disabled(2) This Information Element is NOT transferred to the called party." ::= { atmSigSupportEntry 5 }atmSigSupportBlliRepeatInd OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether to accept, transfer, and deliver the Broadband Repeat Indicator with two or three instances of the Broadband Low Layer Information Element for low layer information selection from the calling party to the called party. This object's value should always be disabled(2) if the value of atmSigSupportLolyrInfo is disabled(2). The value of this object can be: - enabled(1) This Information Element is transferred to the called party - disabled(2) This Information Element is NOT transferred to the called party." ::= { atmSigSupportEntry 6 }atmSigSupportAALInfo OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether to accept, transfer, and deliver the ATM Adaptation Layer Parameters Information Element from the calling party to the called party. The value of this object can be: - enabled(1) This Information Element is transferred to the called party - disabled(2) This Information Element is NOT transferred to the called party." ::= { atmSigSupportEntry 7 }atmSigSupportPrefCarrier OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0|4)) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter identifies the carrier to which intercarrier calls originated from this interface are routed when transit network selection information is not provided by the calling party. If a Carrier Identification Code (CIC) is used the parameter shall contain the CIC. For three-digit CICs, the first octet shall be '0' and the CIC is contained in the three following octets. If the preferred carrier feature is not supported the value is a zero-length string." ::= { atmSigSupportEntry 8 } -- 5. ATM Signalling Descriptor Parameter Table atmSigDescrParamTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmSigDescrParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table contains signalling capabilities of VCLs except the Traffic Descriptor. Traffic descriptors are described in the atmTrafficDescrParamTable." REFERENCE "ATM User-Network Interface Specification, Version 3.1 (UNI 3.1), September 1994, Section 5.4.5 Variable Length Information Elements." ::= { atm2MIBObjects 5 } atmSigDescrParamEntry OBJECT-TYPE SYNTAX AtmSigDescrParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry in this table represents a set of signalling capabilities that can be applied to a VCL. There is no requirement for unique entries, except that the index must be unique." INDEX { atmSigDescrParamIndex } ::= { atmSigDescrParamTable 1 } AtmSigDescrParamEntry ::= SEQUENCE { atmSigDescrParamIndex AtmSigDescrParamIndex, atmSigDescrParamAalType INTEGER, atmSigDescrParamAalSscsType INTEGER, atmSigDescrParamBhliType INTEGER, atmSigDescrParamBhliInfo OCTET STRING, atmSigDescrParamBbcConnConf INTEGER, atmSigDescrParamBlliLayer2 INTEGER, atmSigDescrParamBlliLayer3 INTEGER, atmSigDescrParamBlliPktSize INTEGER, atmSigDescrParamBlliSnapId INTEGER, atmSigDescrParamBlliOuiPid OCTET STRING, atmSigDescrParamRowStatus RowStatus } atmSigDescrParamIndex OBJECT-TYPE SYNTAX AtmSigDescrParamIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "The value of this object is used by the atmVclGenSigDescrIndex object in the atmVclGenTable to identify a row in this table." ::= { atmSigDescrParamEntry 1 } atmSigDescrParamAalType OBJECT-TYPE SYNTAX INTEGER { other(1), -- not defined aal1(2), -- AAL type 1 aal34(3), -- AAL type 3/4 aal5(4), -- AAL type 5 userDefined(5), -- User-Defined AAL aal2(6) -- AAL type 2 } MAX-ACCESS read-create STATUS current DESCRIPTION "The AAL type. The value of this object is set to other(1) when not defined." DEFVAL { other } ::= { atmSigDescrParamEntry 2 } atmSigDescrParamAalSscsType OBJECT-TYPE SYNTAX INTEGER { other(1), -- other, or not used assured(2), -- Data SSCS based on SSCOP -- assured operation nonassured(3), -- Data SSCS based on SSCOP -- non-assured operation frameRelay(4), -- frame relay SSCS null(5) -- null } MAX-ACCESS read-create STATUS current DESCRIPTION "The SSCS type used by this entry." DEFVAL { other } ::= { atmSigDescrParamEntry 3 } atmSigDescrParamBhliType OBJECT-TYPE SYNTAX INTEGER { other(1), -- not defined iso(2), -- ISO user(3), -- User specific hiProfile(4), -- Higher layer profile -- this enum applicable to -- UNI 3.0 only vendorSpecific(5) -- Vender specific -- application identifier } MAX-ACCESS read-create STATUS current DESCRIPTION "The Broadband high layer type." DEFVAL { other } ::= { atmSigDescrParamEntry 4 } atmSigDescrParamBhliInfo OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..8)) MAX-ACCESS read-create STATUS current DESCRIPTION "The Broadband high layer information. When atmSigDescrParamBhliType is set to iso(2), the value of this object is a zero length string. When atmSigDescrParamBhliType is set to user(3), the value of this object is an octet string with length ranging from 0 to 8. When atmSigDescrParamBhliType is set to hiProfile(4), the value of this object is a length of 4 octet string containing user to user profile identifier. When atmSigDescrParamBhliType is set to vendorSpecific(5), the value of this object is a length of 7 octet string, where the most significant 3 octets consist of a globally- administered OUI, and the least significant 4 octets are the vender administered application OUI." DEFVAL { ''H } ::= { atmSigDescrParamEntry 5 } atmSigDescrParamBbcConnConf OBJECT-TYPE SYNTAX INTEGER { ptp(1), -- point-to-point ptmp(2) -- point-to-multipoint } MAX-ACCESS read-create STATUS current DESCRIPTION "The Broadband bearer capability user plane connection configuration parameter." DEFVAL { ptp } ::= { atmSigDescrParamEntry 6 } atmSigDescrParamBlliLayer2 OBJECT-TYPE SYNTAX INTEGER { other(1), -- not specified iso1745(2), -- Basic mode ISO 1745 q921(3), -- CCITT Recommendation Q.921 x25linklayer(4), -- CCITT Recommendation X.25 -- Link Layer x25multilink(5), -- CCITT Recommendation X.25 -- Multilink lapb(6), -- Extended LAPB; for half -- duplex operation hdlcArm(7), -- HDLC ARM (ISO 4335) hdlcNrm(8), -- HDLC NRM (ISO 4335) hdlcAbm(9), -- HDLC ABM (ISO 4335) iso88022(10), -- LAN logical link control -- (ISO 8802/2) x75slp(11), -- CCITT Recommendation X.75, -- single link -- procedure (SLP) q922(12), -- CCITT Recommendation Q.922 userDef(13), -- User specified iso7776(14) -- ISO 7776 DTE-DTE operation
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -