📄 sonet-mib
字号:
::= { sonetPathIntervalEntry 5 }sonetPathIntervalValidData OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates if the data for this interval is valid." ::= { sonetPathIntervalEntry 6 }-- The SONET/SDH Far End Path group-- This group consists of two tables:-- - SONET/SDH Far End Path Current Table-- - SONET/SDH Far End Path Interval Table-- The SONET/SDH Far End Path Current Table-- The SONET/SDH Far End Path Current table-- contains various statistics-- being collected for the current 15 minute interval.-- The statistics are collected from-- the far end block error code-- (FEBE) within the G1 byte of the Path Overhead.-- The definitions are the same as described for-- the near-end information.sonetFarEndPathCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF SonetFarEndPathCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The SONET/SDH Far End Path Current table." ::= { sonetFarEndPath 1 }sonetFarEndPathCurrentEntry OBJECT-TYPE SYNTAX SonetFarEndPathCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the SONET/SDH Far End Path Current table." INDEX { ifIndex } ::= { sonetFarEndPathCurrentTable 1 }SonetFarEndPathCurrentEntry ::= SEQUENCE { sonetFarEndPathCurrentESs PerfCurrentCount, sonetFarEndPathCurrentSESs PerfCurrentCount, sonetFarEndPathCurrentCVs PerfCurrentCount, sonetFarEndPathCurrentUASs PerfCurrentCount }sonetFarEndPathCurrentESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End Errored Seconds encountered by a SONET/SDH interface in the current 15 minute interval." ::= { sonetFarEndPathCurrentEntry 1 }sonetFarEndPathCurrentSESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End Severely Errored Seconds encountered by a SONET/SDH Path interface in the current 15 minute interval." ::= { sonetFarEndPathCurrentEntry 2 }sonetFarEndPathCurrentCVs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End Coding Violations reported via the far end block error count encountered by a SONET/SDH Path interface in the current 15 minute interval." ::= { sonetFarEndPathCurrentEntry 3 }sonetFarEndPathCurrentUASs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End Unavailable Seconds encountered by a SONET/SDH Path interface in the current 15 minute interval." ::= { sonetFarEndPathCurrentEntry 4 }-- The SONET/SDH Far End Path Interval Table-- The SONET/SDH Far End Path Interval Table-- contains various statistics-- collected by each system over a maximum-- of the previous 24 hours of-- operation. The past 24 hours may be broken into 96-- completed 15 minute intervals.-- A system is required to store at-- least 4 completed 15 minute interval.-- The default value is 32 intervals.sonetFarEndPathIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF SonetFarEndPathIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The SONET/SDH Far End Path Interval table." ::= { sonetFarEndPath 2 }sonetFarEndPathIntervalEntry OBJECT-TYPE SYNTAX SonetFarEndPathIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the SONET/SDH Far End Path Interval table." INDEX { ifIndex, sonetFarEndPathIntervalNumber } ::= { sonetFarEndPathIntervalTable 1 }SonetFarEndPathIntervalEntry ::= SEQUENCE { sonetFarEndPathIntervalNumber Integer32, sonetFarEndPathIntervalESs PerfIntervalCount, sonetFarEndPathIntervalSESs PerfIntervalCount, sonetFarEndPathIntervalCVs PerfIntervalCount, sonetFarEndPathIntervalUASs PerfIntervalCount, sonetFarEndPathIntervalValidData TruthValue }sonetFarEndPathIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A number between 1 and 96, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the most recently completed 15 minute interval, and the interval identified by N is the interval immediately preceding the one identified by N-1." ::= { sonetFarEndPathIntervalEntry 1 }sonetFarEndPathIntervalESs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End Errored Seconds encountered by a SONET/SDH Path interface in a particular 15-minute interval in the past 24 hours." ::= { sonetFarEndPathIntervalEntry 2 }sonetFarEndPathIntervalSESs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End Severely Errored Seconds encountered by a SONET/SDH Path interface in a particular 15-minute interval in the past 24 hours." ::= { sonetFarEndPathIntervalEntry 3 }sonetFarEndPathIntervalCVs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End Coding Violations reported via the far end block error count encountered by a SONET/SDH Path interface in a particular 15-minute interval in the past 24 hours." ::= { sonetFarEndPathIntervalEntry 4 }sonetFarEndPathIntervalUASs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End Unavailable Seconds encountered by a SONET/SDH Path interface in a particular 15-minute interval in the past 24 hours." ::= { sonetFarEndPathIntervalEntry 5 }sonetFarEndPathIntervalValidData OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates if the data for this interval is valid." ::= { sonetFarEndPathIntervalEntry 6 }-- the SONET/SDH Virtual Tributary group-- this group consists of 2 tables:-- - the SONET/SDH VT Current Table-- - the SONET/SDH VT Interval Table-- Corresponding SDH signals for SONET VTs are-- as follows:-- A VT1.5 = TU11-- A VT2 = TU12-- A VT3 = none-- none = TU3-- A VT6 = TU2-- the SONET/SDH VT Current Table-- The SONET/SDH VT current table-- contains various statistics-- being collected for the-- current 15 minute interval.sonetVTCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF SonetVTCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The SONET/SDH VT Current table."::= { sonetVT 1 }sonetVTCurrentEntry OBJECT-TYPE SYNTAX SonetVTCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the SONET/SDH VT Current table." INDEX { ifIndex }::= { sonetVTCurrentTable 1 }SonetVTCurrentEntry ::= SEQUENCE { sonetVTCurrentWidth INTEGER, sonetVTCurrentStatus Integer32, sonetVTCurrentESs PerfCurrentCount, sonetVTCurrentSESs PerfCurrentCount, sonetVTCurrentCVs PerfCurrentCount, sonetVTCurrentUASs PerfCurrentCount }sonetVTCurrentWidth OBJECT-TYPE SYNTAX INTEGER { vtWidth15VC11(1), vtWidth2VC12(2), vtWidth3(3), vtWidth6VC2(4), vtWidth6c(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "A value that indicates the type of the SONET VT and SDH VC. Assigned widths are VT1.5/VC11, VT2/VC12, VT3, VT6/VC2, and VT6c."::= { sonetVTCurrentEntry 1 }sonetVTCurrentStatus OBJECT-TYPE SYNTAX Integer32 (1..126) MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the status of the interface. The sonetVTCurrentStatus is a bit map represented as a sum, therefore, it can represent multiple defects and failures simultaneously. The sonetVTNoDefect should be set if and only if no other flag is set. The various bit positions are: 1 sonetVTNoDefect 2 sonetVTLOP 4 sonetVTPathAIS 8 sonetVTPathRDI 16 sonetVTPathRFI 32 sonetVTUnequipped 64 sonetVTSignalLabelMismatch"::= { sonetVTCurrentEntry 2 }sonetVTCurrentESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Errored Seconds encountered by a SONET/SDH VT in the current 15 minute interval."::= { sonetVTCurrentEntry 3 }sonetVTCurrentSESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH VT in the current 15 minute interval."::= { sonetVTCurrentEntry 4 }sonetVTCurrentCVs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Coding Violations encountered by a SONET/SDH VT in the current 15 minute interval."::= { sonetVTCurrentEntry 5 }sonetVTCurrentUASs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Unavailable Seconds encountered by a VT in the current 15 minute interval."::= { sonetVTCurrentEntry 6 }-- the SONET/SDH VT Interval Table-- The SONET/SDH VT Interval Table-- contains various statistics-- collected by each system over a maximum-- of the previous 24 hours of-- operation. The past 24 hours may be broken into 96-- completed 15 minute intervals.-- A system is required to store at-- least 4 completed 15 minute interval.-- The default value is 32 intervals.sonetVTIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF SonetVTIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The SONET/SDH VT Interval table."::= { sonetVT 2 }sonetVTIntervalEntry OBJECT-TYPE SYNTAX SonetVTIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the SONET/SDH VT Interval table." INDEX { ifIndex, sonetVTIntervalNumber }::= { sonetVTIntervalTable 1 }SonetVTIntervalEntry ::= SEQUENCE { sonetVTIntervalNumber Integer32, sonetVTIntervalESs PerfIntervalCount, sonetVTIntervalSESs PerfIntervalCount, sonetVTIntervalCVs PerfIntervalCount, sonetVTIntervalUASs PerfIntervalCount, sonetVTIntervalValidData TruthValue }sonetVTIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A number between 1 and 96, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the most recently completed 15 minute interval, and the interval identified by N is the interval immediately preceding the one identified by N-1."::= { sonetVTIntervalEntry 1 }
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -