⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 vdsl-line-mib

📁 很不错java的SNMP应用例子
💻
📖 第 1 页 / 共 5 页
字号:
                                 a valid frame.        2   lossOfSignal         Vtu failure due to not receiving                                 signal.        3   lossOfPower          Vtu failure due to loss of power.        4   lossOfSignalQuality  Loss of Signal Quality is declared                                 when the Noise Margin falls below                                 the Minimum Noise Margin, or the                                 bit-error-rate exceeds 10^-7.        5   lossOfLink           Vtu failure due to inability to                                 link with peer Vtu.  Set whenever                                 the transceiver is in the 'Warm                                 Start' state.        6   dataInitFailure      Vtu failure during initialization                                 due to bit errors corrupting                                 startup exchange data.        7   configInitFailure    Vtu failure during initialization                                 due to peer Vtu not able to                                 support requested configuration.        8   protocolInitFailure  Vtu failure during initialization                                 due to incompatible protocol used                                 by the peer Vtu.        9   noPeerVtuPresent     Vtu failure during initialization                                 due to no activation sequence                                 detected from peer Vtu.        This is intended to supplement ifOperStatus."    REFERENCE    "T1E1.4/2000-009R3, Part 1, common spec"     ::= { vdslPhysEntry 7 }vdslPhysCurrOutputPwr OBJECT-TYPE    SYNTAX       Integer32 (0..160)    UNITS        "0.1dBm"    MAX-ACCESS   read-only    STATUS       current    DESCRIPTION        "Measured total output power transmitted by this VTU.        This is the measurement that was reported during        the last activation sequence."    REFERENCE    "T1E1.4/2000-009R3, Part 1, common spec"    ::= { vdslPhysEntry 8 }vdslPhysCurrAttainableRate OBJECT-TYPE    SYNTAX       Gauge32    UNITS        "kbps"    MAX-ACCESS   read-only    STATUS       current    DESCRIPTION        "Indicates the maximum currently attainable data rate        in steps of 1000 bits/second by the Vtu.  This value        will be equal to or greater than vdslPhysCurrLineRate.        Note that for SCM, the minimum and maximum data rates        are equal.  Note: 1 kbps = 1000 bps."    REFERENCE    "T1E1.4/2000-009R3, Part 1, common spec"    ::= { vdslPhysEntry 9 }vdslPhysCurrLineRate OBJECT-TYPE    SYNTAX       Gauge32    UNITS        "kbps"    MAX-ACCESS   read-only    STATUS       current    DESCRIPTION        "Indicates the current data rate in steps of 1000        bits/second by the Vtu.  This value will be less than        or equal to vdslPhysCurrAttainableRate.  Note: 1 kbps =        1000 bps."    REFERENCE    "T1E1.4/2000-009R3, Part 1, common spec"    ::= { vdslPhysEntry 10 }vdslChanTable OBJECT-TYPE    SYNTAX       SEQUENCE OF VdslChanEntry    MAX-ACCESS   not-accessible    STATUS       current    DESCRIPTION        "This table provides one row for each Vtu channel.        VDSL channel interfaces are those ifEntries where        ifType is equal to interleave(124) or fast(125)."    ::= { vdslMibObjects 3 }vdslChanEntry OBJECT-TYPE    SYNTAX       VdslChanEntry    MAX-ACCESS   not-accessible    STATUS       current    DESCRIPTION        "An entry in the vdslChanTable."    INDEX { ifIndex,            vdslPhysSide }    ::= { vdslChanTable 1 }VdslChanEntry ::=    SEQUENCE        {        vdslChanInterleaveDelay        Gauge32,        vdslChanCrcBlockLength         Gauge32,        vdslChanCurrTxRate             Gauge32,        vdslChanCurrTxSlowBurstProtect Gauge32,        vdslChanCurrTxFastFec          Gauge32        }vdslChanInterleaveDelay OBJECT-TYPE    SYNTAX       Gauge32    UNITS        "milliseconds"    MAX-ACCESS   read-only    STATUS       current    DESCRIPTION        "Interleave Delay for this channel.        Interleave delay applies only to the interleave        (slow) channel and defines the mapping (relative        spacing) between subsequent input bytes at the        interleaver input and their placement in the bit        stream at the interleaver output.  Larger numbers        provide greater separation between consecutive        input bytes in the output bit stream allowing for        improved impulse noise immunity at the expense of        payload latency.        In the case where the ifType is fast(125), return        a value of zero."    REFERENCE    "T1E1.4/2000-009R3, Part 1, common spec"    ::= { vdslChanEntry 1 }vdslChanCrcBlockLength OBJECT-TYPE    SYNTAX       Gauge32    UNITS        "bytes"    MAX-ACCESS   read-only    STATUS       current    DESCRIPTION        "Indicates the length of the channel data-block        on which the CRC operates."    REFERENCE    "T1E1.4/2000-009R3, Part 1, common spec"    ::= { vdslChanEntry 2 }vdslChanCurrTxRate OBJECT-TYPE    SYNTAX       Gauge32    UNITS        "kbps"    MAX-ACCESS   read-only    STATUS       current    DESCRIPTION        "Actual transmit data rate on this channel.  Note: 1        kbps = 1000 bps."    ::= { vdslChanEntry 3 }vdslChanCurrTxSlowBurstProtect OBJECT-TYPE    SYNTAX       Gauge32 (0..1275)    UNITS        "microseconds"    MAX-ACCESS   read-only    STATUS       current    DESCRIPTION        "Actual level of impulse noise (burst) protection        for an interleaved (slow) channel.  This parameter is        not applicable to fast channels.  For fast channels,        a value of zero shall be returned."    REFERENCE    "ITU-T G.997.1, section 7.3.2.3"    ::= { vdslChanEntry 4 }vdslChanCurrTxFastFec OBJECT-TYPE    SYNTAX       Gauge32 (0..50)    UNITS        "%"    MAX-ACCESS   read-only    STATUS       current    DESCRIPTION        "Actual Forward Error Correction (FEC) redundancy        related overhead for a fast channel.  This parameter        is not applicable to an interleaved (slow) channel.        For interleaved channels, a value of zero shall be        returned."    ::= { vdslChanEntry 5 }vdslPerfDataTable       OBJECT-TYPE    SYNTAX       SEQUENCE OF VdslPerfDataEntry    MAX-ACCESS   not-accessible    STATUS       current    DESCRIPTION        "This table provides one row for each VDSL physical        interface.  VDSL physical interfaces are those ifEntries        where ifType is equal to vdsl(97)."    ::= { vdslMibObjects 4 }vdslPerfDataEntry       OBJECT-TYPE    SYNTAX        VdslPerfDataEntry    MAX-ACCESS    not-accessible    STATUS        current    DESCRIPTION        "An entry in the vdslPerfDataTable."    INDEX { ifIndex,            vdslPhysSide }    ::= { vdslPerfDataTable 1 }VdslPerfDataEntry ::=    SEQUENCE        {        vdslPerfDataValidIntervals         HCPerfValidIntervals,        vdslPerfDataInvalidIntervals       HCPerfInvalidIntervals,        vdslPerfDataLofs                   Unsigned32,        vdslPerfDataLoss                   Unsigned32,        vdslPerfDataLprs                   Unsigned32,        vdslPerfDataLols                   Unsigned32,        vdslPerfDataESs                    Unsigned32,        vdslPerfDataSESs                   Unsigned32,        vdslPerfDataUASs                   Unsigned32,        vdslPerfDataInits                  Unsigned32,        vdslPerfDataCurr15MinTimeElapsed   HCPerfTimeElapsed,        vdslPerfDataCurr15MinLofs          HCPerfCurrentCount,        vdslPerfDataCurr15MinLoss          HCPerfCurrentCount,        vdslPerfDataCurr15MinLprs          HCPerfCurrentCount,        vdslPerfDataCurr15MinLols          HCPerfCurrentCount,        vdslPerfDataCurr15MinESs           HCPerfCurrentCount,        vdslPerfDataCurr15MinSESs          HCPerfCurrentCount,        vdslPerfDataCurr15MinUASs          HCPerfCurrentCount,        vdslPerfDataCurr15MinInits         HCPerfCurrentCount,        vdslPerfData1DayValidIntervals     HCPerfValidIntervals,        vdslPerfData1DayInvalidIntervals   HCPerfInvalidIntervals,        vdslPerfDataCurr1DayTimeElapsed    HCPerfTimeElapsed,        vdslPerfDataCurr1DayLofs           Unsigned32,        vdslPerfDataCurr1DayLoss           Unsigned32,        vdslPerfDataCurr1DayLprs           Unsigned32,        vdslPerfDataCurr1DayLols           Unsigned32,        vdslPerfDataCurr1DayESs            Unsigned32,        vdslPerfDataCurr1DaySESs           Unsigned32,        vdslPerfDataCurr1DayUASs           Unsigned32,        vdslPerfDataCurr1DayInits          Unsigned32        }vdslPerfDataValidIntervals OBJECT-TYPE    SYNTAX       HCPerfValidIntervals    UNITS        "intervals"    MAX-ACCESS   read-only    STATUS       current    DESCRIPTION        "Valid Intervals per definition found in        HC-PerfHist-TC-MIB."    ::= { vdslPerfDataEntry 1 }vdslPerfDataInvalidIntervals OBJECT-TYPE    SYNTAX       HCPerfInvalidIntervals    UNITS        "intervals"    MAX-ACCESS   read-only    STATUS       current    DESCRIPTION        "Invalid Intervals per definition found in        HC-PerfHist-TC-MIB."    ::= { vdslPerfDataEntry 2 }vdslPerfDataLofs OBJECT-TYPE    SYNTAX       Unsigned32    UNITS        "seconds"    MAX-ACCESS   read-only    STATUS       current    DESCRIPTION        "Count of seconds since the unit was last reset that there        was Loss of Framing."    REFERENCE    "T1E1.4/2000-009R3, Part 1, common spec"    ::= { vdslPerfDataEntry 3 }vdslPerfDataLoss OBJECT-TYPE    SYNTAX       Unsigned32    UNITS        "seconds"    MAX-ACCESS   read-only    STATUS       current    DESCRIPTION        "Count of seconds since the unit was last reset that there        was Loss of Signal."    REFERENCE    "T1E1.4/2000-009R3, Part 1, common spec"    ::= { vdslPerfDataEntry 4 }vdslPerfDataLprs OBJECT-TYPE    SYNTAX       Unsigned32    UNITS        "seconds"    MAX-ACCESS   read-only    STATUS       current    DESCRIPTION        "Count of seconds since the unit was last reset that there        was Loss of Power."    REFERENCE    "T1E1.4/2000-009R3, Part 1, common spec"    ::= { vdslPerfDataEntry 5 }vdslPerfDataLols OBJECT-TYPE    SYNTAX       Unsigned32    UNITS        "seconds"    MAX-ACCESS   read-only    STATUS       current    DESCRIPTION        "Count of seconds since the unit was last reset that there        was Loss of Link."    ::= { vdslPerfDataEntry 6 }vdslPerfDataESs OBJECT-TYPE    SYNTAX       Unsigned32    UNITS        "seconds"    MAX-ACCESS   read-only    STATUS       current    DESCRIPTION        "Count of Errored Seconds since the unit was last reset.        An Errored Second is a one-second interval containing one        or more CRC anomalies, or one or more LOS or LOF defects."    REFERENCE    "T1E1.4/2000-009R3, Part 1, common spec"    ::= { vdslPerfDataEntry 7 }vdslPerfDataSESs OBJECT-TYPE    SYNTAX       Unsigned32    UNITS        "seconds"    MAX-ACCESS   read-only    STATUS       current    DESCRIPTION        "Count of Severely Errored Seconds since the unit was last        reset."    ::= { vdslPerfDataEntry 8 }vdslPerfDataUASs OBJECT-TYPE    SYNTAX       Unsigned32    UNITS        "seconds"    MAX-ACCESS   read-only    STATUS       current    DESCRIPTION        "Count of Unavailable Seconds since the unit was last        reset."    ::= { vdslPerfDataEntry 9 }vdslPerfDataInits OBJECT-TYPE    SYNTAX       Unsigned32    UNITS        "occurrences"    MAX-ACCESS   read-only    STATUS       current    DESCRIPTION        "Count of the line initialization attempts since the unit        was last reset.  This count includes both successful and        failed attempts."    REFERENCE    "T1E1.4/2000-009R3, Part 1, common spec"    ::= { vdslPerfDataEntry 10 }vdslPerfDataCurr15MinTimeElapsed OBJECT-TYPE    SYNTAX       HCPerfTimeElapsed    UNITS        "seconds"    MAX-ACCESS   read-only    STATUS       current    DESCRIPTION        "Total elapsed seconds in this interval."    ::= { vdslPerfDataEntry 11 }vdslPerfDataCurr15MinLofs OBJECT-TYPE    SYNTAX       HCPerfCurrentCount    UNITS        "seconds"    MAX-ACCESS   read-only    STATUS       current    DESCRIPTION        "Count of seconds during this interval that there        was Loss of Framing."    REFERENCE    "T1E1.4/2000-009R3, Part 1, common spec"    ::= { vdslPerfDataEntry 12 }vdslPerfDataCurr15MinLoss OBJECT-TYPE    SYNTAX       HCPerfCurrentCount    UNITS        "seconds"    MAX-ACCESS   read-only    STATUS       current    DESCRIPTION        "Count of seconds during this interval that there        was Loss of Signal."    REFERENCE    "T1E1.4/2000-009R3, Part 1, common spec"    ::= { vdslPerfDataEntry 13 }vdslPerfDataCurr15MinLprs OBJECT-TYPE    SYNTAX       HCPerfCurrentCount    UNITS        "seconds"    MAX-ACCESS   read-only    STATUS       current    DESCRIPTION        "Count of seconds during this interval that there        was Loss of Power."    REFERENCE    "T1E1.4/2000-009R3, Part 1, common spec"    ::= { vdslPerfDataEntry 14 }vdslPerfDataCurr15MinLols OBJECT-TYPE    SYNTAX       HCPerfCurrentCount

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -