<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN"        "http://www.w3.org/TR/html4/loose.dtd"><html lang="en"><head><title>DscQMMSetLoadRegister - Universal Driver Documentation</title><meta http-equiv="Content-type" content="text/html; charset=iso-8859-1"><meta name="robots" content="index,follow"><link rel="shortcut icon" href="/favicon.ico"><link rel="stylesheet" href="/dscud/style/wikiprintable.css"><script type="text/javascript" src="/dscud/style/wikibits.js"></script><style type='text/css'><!--a.new, #quickbar a.new { color: #CC2200; }#quickbar { position: absolute; top: 4px; left: 4px; border-right: 1px solid gray; }#article { margin-left: 152px; margin-right: 4px; }//--></style></head><body bgcolor='#FFFFFF'><div class='titlebox'><h1 class='pagetitle'>DscQMMSetLoadRegister</h1><span class='subtitle'>Universal Driver Documentation</span></div><div class='navbox'><a href="manual_Main_Page.html" class='printable' title ="Main Page">Main Page</a> || <a href="manual_Table_of_Contents.html" class='printable' title ="Table of Contents">Table_of_Contents</a> || <a href="http://www.diamondsystems.com/">Diamond Systems Website</a></div></div><div class='bodytext'>This function loads the supplied data into the specified counter's Load register. The Load register is used to specify a counter's initial value as well as to set the reload value when the counter reaches its terminal count during repetitive counting modes.
The data is not actually loaded into the counter's count register until a Load or Load and Arm command is issued with <a href="manual_DscQMMCounterControl.html" class='printable' title ="DscQMMCounterControl">dscQMMCounterControl</a>().
<p>
<h2><a name="Function_Definition">Function Definition</a></h2>
<p>
BYTE dscQMMSetLoadRegister(<a href="manual_DSCB.html" class='printable' title ="DSCB">DSCB</a> board, BYTE counter, WORD value)
<p>
<h2><a name="Function_Parameters">Function Parameters</a></h2>
<p>
<table border=1><tr ><TH>Name</TH><TH>Description</TH></tr><tr ><TD>board</TD><TD>The handle of the board to operate on</TD></tr><tr ><TD>counter</TD><TD>Counter no., 1-5 for QMM-5, 1-10 for QMM-10</TD></tr><tr ><TD>value</TD><TD>16-bit load value, range 0-65535</TD></tr></table><p>
<h2><a name="Return_Value">Return Value</a></h2>
<p>
Error code or 0.