⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc1315.mib

📁 opennms得相关源码 请大家看看
💻 MIB
📖 第 1 页 / 共 2 页
字号:
             STATUS   mandatory             DESCRIPTION                "The Data Link Connection Identifier  for  this                virtual circuit."            REFERENCE               "Draft American National  Standard  T1.618-1991,               Section 3.3.6"           ::= { frCircuitEntry 2 }         frCircuitState OBJECT-TYPE             SYNTAX   INTEGER {                         invalid (1),                         active (2),                         inactive (3)                      }             ACCESS   read-write             STATUS   mandatory             DESCRIPTION                "Indicates whether the particular virtual  cir-                cuit  is operational.  In the absence of a Data                Link Connection Management  Interface,  virtual                circuit  entries  (rows) may be created by set-                ting virtual  circuit  state  to  'active',  or                deleted by changing Circuit state to 'invalid'.                Whether or not the row actually  disappears  is                left  to the implementation, so this object may                actually read as 'invalid' for  some  arbitrary                length  of  time.   It is also legal to set the                state of a virtual  circuit  to  'inactive'  to                temporarily disable a given circuit."            DEFVAL { active }            ::= { frCircuitEntry 3 }         frCircuitReceivedFECNs OBJECT-TYPE             SYNTAX   Counter             ACCESS   read-only             STATUS   mandatory             DESCRIPTION                "Number of frames received from the network in-                dicating  forward  congestion since the virtual                circuit was created."            REFERENCE               "Draft American National  Standard  T1.618-1991,               Section 3.3.3"           ::= { frCircuitEntry 4 }         frCircuitReceivedBECNs OBJECT-TYPE             SYNTAX   Counter             ACCESS   read-only             STATUS   mandatory             DESCRIPTION                "Number of frames received from the network in-                dicating  backward congestion since the virtual                circuit was created."            REFERENCE               "Draft American National  Standard  T1.618-1991,               Section 3.3.4"           ::= { frCircuitEntry 5 }         frCircuitSentFrames OBJECT-TYPE             SYNTAX   Counter             ACCESS   read-only             STATUS   mandatory             DESCRIPTION                "The number of frames sent  from  this  virtual                circuit since it was created."            ::= { frCircuitEntry 6 }         frCircuitSentOctets OBJECT-TYPE             SYNTAX   Counter             ACCESS   read-only             STATUS   mandatory             DESCRIPTION                "The number of octets sent  from  this  virtual                circuit since it was created."            ::= { frCircuitEntry 7 }         frCircuitReceivedFrames OBJECT-TYPE             SYNTAX   Counter             ACCESS   read-only             STATUS   mandatory             DESCRIPTION                "Number of frames received  over  this  virtual                circuit since it was created."            ::= { frCircuitEntry 8 }         frCircuitReceivedOctets OBJECT-TYPE             SYNTAX   Counter             ACCESS   read-only             STATUS   mandatory             DESCRIPTION                "Number of octets received  over  this  virtual                circuit since it was created."            ::= { frCircuitEntry 9 }         frCircuitCreationTime OBJECT-TYPE             SYNTAX   TimeTicks             ACCESS   read-only             STATUS   mandatory             DESCRIPTION                "The value of sysUpTime when the  virtual  cir-                cuit was created, whether by the Data Link Con-                nection Management Interface  or  by  a  SetRe-                quest."            ::= { frCircuitEntry 10 }         frCircuitLastTimeChange OBJECT-TYPE             SYNTAX   TimeTicks             ACCESS   read-only             STATUS   mandatory             DESCRIPTION                "The value of sysUpTime when last there  was  a                change in the virtual circuit state"            ::= { frCircuitEntry 11 }         frCircuitCommittedBurst OBJECT-TYPE             SYNTAX   INTEGER             ACCESS   read-write             STATUS   mandatory             DESCRIPTION                "This variable indicates the maximum amount  of                data,  in  bits,  that  the  network  agrees to                transfer under normal  conditions,  during  the                measurement interval."            REFERENCE               "Draft American National  Standard  T1.617-1991,               Section 6.5.19"           DEFVAL   { 0 }  -- the default indicates no commitment           ::= { frCircuitEntry 12 }         frCircuitExcessBurst OBJECT-TYPE             SYNTAX   INTEGER             ACCESS   read-write             STATUS   mandatory             DESCRIPTION                "This variable indicates the maximum amount  of                uncommitted data bits that the network will at-                tempt to deliver over the measurement interval.                By default, if not configured when creating the                entry, the Excess Information Burst Size is set                to the value of ifSpeed."            REFERENCE               "Draft American National  Standard  T1.617-1991,               Section 6.5.19"                   ::= { frCircuitEntry 13 }         frCircuitThroughput OBJECT-TYPE             SYNTAX   INTEGER             ACCESS   read-write             STATUS   mandatory             DESCRIPTION                "Throughput is the average number of 'Frame Re-                lay  Information  Field'  bits  transferred per                second across a user network interface  in  one                direction, measured over the measurement inter-                val.                If the  configured  committed  burst  rate  and                throughput  are  both non-zero, the measurement                interval                T=frCircuitCommittedBurst/frCircuitThroughput.                If the  configured  committed  burst  rate  and                throughput  are  both zero, the measurement in-                terval                       T=frCircuitExcessBurst/ifSpeed."            REFERENCE               "Draft American National  Standard  T1.617-1991,               Section 6.5.19"           DEFVAL {0}  -- the default value of Throughput is                       -- "no commitment".           ::= { frCircuitEntry 14 }     --  Error Table     -- The table describing errors encountered on each Frame     -- Relay Interface.     frErrTable OBJECT-TYPE         SYNTAX   SEQUENCE OF FrErrEntry         ACCESS   not-accessible         STATUS   mandatory         DESCRIPTION            "A table containing information about Errors on the            Frame Relay interface."         ::= { frame-relay 3 }         frErrEntry OBJECT-TYPE             SYNTAX   FrErrEntry             ACCESS   not-accessible             STATUS   mandatory             DESCRIPTION                "The error information for a single frame relay                interface."            INDEX { frErrIfIndex }            ::= { frErrTable 1 }         FrErrEntry ::=             SEQUENCE {                 frErrIfIndex                     Index,                 frErrType                     INTEGER,                 frErrData                     OCTET STRING,                 frErrTime                     TimeTicks         }         frErrIfIndex OBJECT-TYPE             SYNTAX   Index             ACCESS   read-only             STATUS   mandatory             DESCRIPTION                "The ifIndex Value of the  corresponding  ifEn-                try."            ::= { frErrEntry 1 }         frErrType OBJECT-TYPE             SYNTAX   INTEGER {                         unknownError(1),                         receiveShort(2),                         receiveLong(3),                         illegalDLCI(4),                         unknownDLCI(5),                         dlcmiProtoErr(6),                         dlcmiUnknownIE(7),                         dlcmiSequenceErr(8),                         dlcmiUnknownRpt(9),                         noErrorSinceReset(10)                      }             ACCESS   read-only             STATUS   mandatory             DESCRIPTION                "The type of error that was last seen  on  this                interface."            ::= { frErrEntry 2 }         frErrData OBJECT-TYPE             SYNTAX   OCTET STRING             ACCESS   read-only             STATUS   mandatory             DESCRIPTION                "An octet string containing as much of the  er-                ror  packet as possible.  As a minimum, it must                contain the Q.922 Address or  as  much  as  was                delivered.   It is desirable to include all in-                formation up to the PDU."            ::= { frErrEntry 3 }         frErrTime OBJECT-TYPE             SYNTAX   TimeTicks             ACCESS   read-only             STATUS   mandatory             DESCRIPTION                "The value of sysUpTime at which the error  was                detected."            ::= { frErrEntry 4 }         -- Frame Relay Globals         frame-relay-globals OBJECT IDENTIFIER ::= { frame-relay 4 }         frTrapState OBJECT-TYPE             SYNTAX  INTEGER { enabled(1), disabled(2) }             ACCESS   read-write             STATUS   mandatory             DESCRIPTION                "This variable  indicates  whether  the  system                produces the frDLCIStatusChange trap."            DEFVAL { disabled }            ::= { frame-relay-globals 1 }         --  Data Link Connection Management Interface Related Traps         frDLCIStatusChange TRAP-TYPE             ENTERPRISE frame-relay             VARIABLES  { frCircuitIfIndex, frCircuitDlci, frCircuitState }             DESCRIPTION                "This trap indicates that the indicated Virtual                Circuit  has changed state.  It has either been                created or invalidated, or has toggled  between                the active and inactive states."             ::= 1     END

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -