⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 sip-mib

📁 opennms得相关源码 请大家看看
💻
📖 第 1 页 / 共 3 页
字号:
                 a sequence number within the L2PDU not equal to                 the expected sequence number of the SMDS SS                 receive process."              ::= { sipL2Entry 6 }          sipL2MidCurrentlyActiveErrors  OBJECT-TYPE              SYNTAX      Counter32              MAX-ACCESS  read-only              STATUS      current              DESCRIPTION                 "The number of received SIP Level 2 PDUs that are                 BOMs for which an active receive process is                 already started."              ::= { sipL2Entry 7 }          sipL2BomOrSSMsMIDErrors  OBJECT-TYPE              SYNTAX      Counter32              MAX-ACCESS  read-only              STATUS      current              DESCRIPTION                 "The number of received SIP Level 2 PDUs that are                 SSMs with a MID not equal to zero or are BOMs with                 MIDs equal to zero."              ::= { sipL2Entry 8 }          sipL2EomsMIDErrors  OBJECT-TYPE              SYNTAX      Counter32              MAX-ACCESS  read-only              STATUS      current              DESCRIPTION                 "The number of received SIP Level 2 PDUs that are                 EOMs for which there is no active receive process                 for the MID (i.e., the receipt of an EOM which                 does not correspond to a BOM) OR the EOM has a MID                 equal to zero."              ::= { sipL2Entry 9 }          -- The SIP PLCP Group          sipPLCP OBJECT IDENTIFIER ::= { sip 3 }          -- The DS1 PLCP Group          sipDS1PLCPTable  OBJECT-TYPE              SYNTAX      SEQUENCE OF SipDS1PLCPEntry              MAX-ACCESS  not-accessible              STATUS      current              DESCRIPTION                 "This table contains SIP DS1 PLCP parameters and                 state variables, one entry per SIP port."              ::= { sipPLCP 1 }          sipDS1PLCPEntry  OBJECT-TYPE              SYNTAX      SipDS1PLCPEntry              MAX-ACCESS  not-accessible              STATUS      current              DESCRIPTION                 "This list contains SIP DS1 PLCP parameters and                 state variables."              INDEX   { sipDS1PLCPIndex }              ::= { sipDS1PLCPTable 1 }          SipDS1PLCPEntry  ::= SEQUENCE {              sipDS1PLCPIndex       IfIndex,              sipDS1PLCPSEFSs       Counter32,              sipDS1PLCPAlarmState  INTEGER,              sipDS1PLCPUASs        Counter32              }          sipDS1PLCPIndex  OBJECT-TYPE              SYNTAX      IfIndex              MAX-ACCESS  read-only              STATUS      current              DESCRIPTION                 "The value of this object identifies the                 interface for which this entry contains management                 information. "              ::= { sipDS1PLCPEntry 1 }          sipDS1PLCPSEFSs OBJECT-TYPE              SYNTAX       Counter32              MAX-ACCESS   read-only              STATUS       current              DESCRIPTION                 "A DS1 Severely Errored Framing Second (SEFS) is a                 count of one-second intervals containing one or                 more SEF events.  A Severely Errored Framing (SEF)                 event is declared when an error in the A1 octet                 and an error in the A2 octet of a framing octet                 pair (i.e., errors in both framing octets), or two                 consecutive invalid and/or nonsequential Path                 Overhead Identifier octets are detected."              ::= { sipDS1PLCPEntry 2 }          sipDS1PLCPAlarmState OBJECT-TYPE              SYNTAX  INTEGER     {                          noAlarm (1),                          receivedFarEndAlarm (2),                          incomingLOF (3)                      }              MAX-ACCESS  read-only              STATUS      current              DESCRIPTION                 "This variable indicates if there is an alarm                 present for the DS1 PLCP.  The value                 receivedFarEndAlarm means that the DS1 PLCP has                 received an incoming Yellow Signal, the value                 incomingLOF means that the DS1 PLCP has declared a                 loss of frame (LOF) failure condition, and the                 value noAlarm means that there are no alarms                 present.  See TR-TSV-000773 for a description of                 alarm states."              ::= { sipDS1PLCPEntry 3 }          sipDS1PLCPUASs OBJECT-TYPE              SYNTAX      Counter32              MAX-ACCESS  read-only              STATUS      current              DESCRIPTION                 "The counter associated with the number of                 Unavailable Seconds, as defined by TR-TSV-000773,                 encountered by the PLCP."              ::= { sipDS1PLCPEntry 4 }          -- The DS3 PLCP Group          sipDS3PLCPTable  OBJECT-TYPE              SYNTAX      SEQUENCE OF SipDS3PLCPEntry              MAX-ACCESS  not-accessible              STATUS      current              DESCRIPTION                 "This table contains SIP DS3 PLCP parameters and                 state variables, one entry per SIP port."              ::= { sipPLCP 2 }          sipDS3PLCPEntry  OBJECT-TYPE              SYNTAX      SipDS3PLCPEntry              MAX-ACCESS  not-accessible              STATUS      current              DESCRIPTION                 "This list contains SIP DS3 PLCP parameters and                 state variables."              INDEX   { sipDS3PLCPIndex }              ::= { sipDS3PLCPTable 1 }          SipDS3PLCPEntry  ::= SEQUENCE {              sipDS3PLCPIndex       IfIndex,              sipDS3PLCPSEFSs       Counter32,              sipDS3PLCPAlarmState  INTEGER,              sipDS3PLCPUASs        Counter32              }          sipDS3PLCPIndex  OBJECT-TYPE              SYNTAX      IfIndex              MAX-ACCESS  read-only              STATUS      current              DESCRIPTION                 "The value of this object identifies the                 interface for which this entry contains management                 information.  "              ::= { sipDS3PLCPEntry 1 }          sipDS3PLCPSEFSs OBJECT-TYPE              SYNTAX      Counter32              MAX-ACCESS  read-only              STATUS      current              DESCRIPTION                 "A DS3 Severely Errored Framing Second (SEFS) is a                 count of one-second intervals containing one or                 more SEF events.  A Severely Errored Framing (SEF)                 event is declared when an error in the A1 octet                 and an error in the A2 octet of a framing octet                 pair (i.e., errors in both framing octets), or two                 consecutive invalid and/or nonsequential Path                 Overhead Identifier octets are detected."              ::= { sipDS3PLCPEntry 2 }          sipDS3PLCPAlarmState OBJECT-TYPE              SYNTAX  INTEGER     {                          noAlarm (1),                          receivedFarEndAlarm (2),                          incomingLOF (3)                      }              MAX-ACCESS  read-only              STATUS      current              DESCRIPTION                 "This variable indicates if there is an alarm                 present for the DS3 PLCP.  The value                 receivedFarEndAlarm means that the DS3 PLCP has                 received an incoming Yellow Signal, the value                 incomingLOF means that the DS3 PLCP has declared a                 loss of frame (LOF) failure condition, and the                 value noAlarm means that there are no alarms                 present.  See TR-TSV-000773 for a description of                 alarm states."              ::= { sipDS3PLCPEntry 3 }          sipDS3PLCPUASs OBJECT-TYPE              SYNTAX      Counter32              MAX-ACCESS  read-only              STATUS      current              DESCRIPTION                 "The counter associated with the number of                 Unavailable Seconds, as defined by TR-TSV-000773,                 encountered by the PLCP."              ::= { sipDS3PLCPEntry 4 }          -- The SMDS Applications group          -- Applications that have been identified for this group are:          --          * IP-over-SMDS (details are specified in RFC 1209)          smdsApplications OBJECT IDENTIFIER ::= { sip 4 }          ipOverSMDS OBJECT IDENTIFIER ::= { smdsApplications 1 }          -- Although the objects in this group are read-only, at the          -- agent's discretion they may be made read-write so that the          -- management station, when appropriately authorized, may          -- change the addressing information related to the          -- configuration of a logical IP subnetwork implemented on          -- top of SMDS.          -- This table is necessary to support RFC1209 (IP-over-SMDS)          -- and gives information on the Group Addresses and ARP          -- Addresses used in the Logical IP subnetwork.          -- One SMDS address may be associated with multiple IP          -- addresses.  One SNI may be associated with multiple LISs.          ipOverSMDSTable OBJECT-TYPE              SYNTAX      SEQUENCE OF IpOverSMDSEntry              MAX-ACCESS  not-accessible              STATUS      current              DESCRIPTION                 "The table of addressing information relevant to                 this entity's IP addresses."              ::= { ipOverSMDS 1 }          ipOverSMDSEntry OBJECT-TYPE              SYNTAX      IpOverSMDSEntry              MAX-ACCESS  not-accessible              STATUS      current              DESCRIPTION                 "The addressing information for one of this                 entity's IP addresses."              INDEX   { ipOverSMDSIndex, ipOverSMDSAddress }              ::= { ipOverSMDSTable 1 }          IpOverSMDSEntry ::=              SEQUENCE {                 ipOverSMDSIndex       IfIndex,                 ipOverSMDSAddress     IpAddress,                 ipOverSMDSHA          SMDSAddress,                 ipOverSMDSLISGA       SMDSAddress,                 ipOverSMDSARPReq      SMDSAddress                 }          ipOverSMDSIndex OBJECT-TYPE              SYNTAX      IfIndex              MAX-ACCESS  read-only              STATUS      current              DESCRIPTION                 "The value of this object identifies the                 interface for which this entry contains management                 information. "              ::= { ipOverSMDSEntry 1 }          ipOverSMDSAddress OBJECT-TYPE               SYNTAX      IpAddress               MAX-ACCESS  read-only               STATUS      current               DESCRIPTION                 "The IP address to which this entry's addressing                 information pertains."              ::= { ipOverSMDSEntry 2 }          ipOverSMDSHA OBJECT-TYPE              SYNTAX      SMDSAddress              MAX-ACCESS  read-only              STATUS      current              DESCRIPTION                 "The SMDS Individual address of the IP station."              ::= { ipOverSMDSEntry 3 }          ipOverSMDSLISGA OBJECT-TYPE              SYNTAX      SMDSAddress              MAX-ACCESS  read-only              STATUS      current              DESCRIPTION                 "The SMDS Group Address that has been configured                 to identify the SMDS Subscriber-Network Interfaces                 (SNIs) of all members of the Logical IP Subnetwork                 (LIS) connected to the network supporting SMDS."              ::= { ipOverSMDSEntry 4 }          ipOverSMDSARPReq OBJECT-TYPE              SYNTAX      SMDSAddress              MAX-ACCESS  read-only              STATUS      current              DESCRIPTION                 "The SMDS address (individual or group) to which                 ARP Requests are to be sent."              ::= { ipOverSMDSEntry 5 }          -- The SMDS Carrier Selection group          -- This group is used as a place holder          -- for carrier selection objects.          smdsCarrierSelection OBJECT IDENTIFIER ::= { sip 5 }          -- The SIP Error Log          sipErrorLog OBJECT IDENTIFIER ::= { sip 6 }          sipL3PDUErrorTable OBJECT-TYPE              SYNTAX      SEQUENCE OF SipL3PDUErrorEntry              MAX-ACCESS  not-accessible              STATUS      current              DESCRIPTION                 "A table that contains the latest occurrence of                 the following syntactical SIP L3PDU errors:                 - Destination Address Field Format Error,                 The following pertains to the 60 least significant                 bits of the 64 bit address field.  The 60 bits                 contained in the address subfield can be used to                 represent addresses up to 15 decimal digits.  Each                 decimal digit shall be encoded into four bits                 using Binary Coded Decimal (BCD), with the most                 significant digit occurring left-most.  If not all                 15 digits are required, then the remainder of this                 field shall be padded on the right with bits set                 to one.  An error is considered to have occurred:                 a).  if the first four bits of the address                 subfield are not BCD, OR b).  if the first four                 bits of the address subfield are populated with                 the country code value 0001, AND the 40 bits which                 follow are not Binary Coded Decimal (BCD) encoded                 values of the 10 digit addresses, OR the remaining                 16 least significant bits are not populated with                 1's, OR c).  if the address subfield is not                 correct according to another numbering plan which                 is dependent upon the carrier assigning the                 numbers and offering SMDS.                 - Source Address Field Format Error,                 The description of this parameter is the same as                 the description of the Destination Address Field                 Format Error.                 - Invalid BAsize Field Value,                 An error is considered to have occurred when the                 BAsize field of an SIP L3PDU contains a value less                 that 32, greater than 9220 octets without the                 CRC32 field present, greater than 9224 octets with                 the CRC32 field present, or not equal to a                 multiple of 4 octets,                 - Invalid Header Extension Length Field Value,                 An error is considered to have occurred when the                 Header Extension Length field value is not equal                 3.                 - Invalid Header Extension - Element Length,                 An error is considered to have occurred when the                 Header Extension - Element Length is greater than                 12.

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -