⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 fddi-smt73-mib

📁 opennms得相关源码 请大家看看
💻
📖 第 1 页 / 共 5 页
字号:
-- Changes to rfc1512 (FDDI 7.3 SMT MIB):--      Added the IMPORT for transmission.-- dperkins@scruznet.comFDDI-SMT73-MIB DEFINITIONS ::= BEGIN          IMPORTS                  Counter                      FROM RFC1155-SMI                  OBJECT-TYPE                      FROM RFC-1212                  transmission                      FROM RFC1213-MIB;          --  This MIB module uses the extended OBJECT-TYPE macro as          --  defined in [7].          -- this is the FDDI MIB module          fddi    OBJECT IDENTIFIER ::= { transmission 15 }          fddimib   OBJECT IDENTIFIER ::= { fddi 73 }          -- textual conventions          FddiTimeNano ::= INTEGER (0..2147483647)          -- This data type specifies 1 nanosecond units as          -- an integer value.          --          -- NOTE: The encoding is normal integer representation, not          -- two's complement.  Since this type is used for variables          -- which are encoded as TimerTwosComplement in the ANSI          -- specification, two operations need to be performed on such          -- variables to convert from ANSI form to SNMP form:          --          -- 1) Convert from two's complement to normal integer          --    representation          -- 2) Multiply by 80 to convert from 80 nsec to 1 nsec units          --          -- No resolution is lost.  Moreover, the objects for which          -- this data type is used effectively do not lose any range          -- due to the lower maximum value since they do not require          -- the full range.          --          -- Example: If fddimibMACTReq had a value of 8 ms, it would          -- be stored in ANSI TimerTwosComplement format as 0xFFFE7960          -- [8 ms is 100000 in 80 nsec units, which is then converted          -- to two's complement] but be reported as 8000000 in SNMP          -- since it is encoded here as FddiTimeNano.          FddiTimeMilli ::= INTEGER (0..2147483647)          -- This data type is used for some FDDI timers. It specifies          -- time in 1 millisecond units, in normal integer          -- representation.          FddiResourceId ::= INTEGER (0..65535)          -- This data type is used to refer to an instance of a  MAC,          -- PORT, or PATH Resource ID.  Indexing begins          -- at 1.  Zero is used to indicate the absence of a resource.          FddiSMTStationIdType ::= OCTET STRING (SIZE (8))          -- The unique identifier for the FDDI station.  This is a          -- string of 8 octets, represented as X' yy yy xx xx xx xx          -- xx xx' with the low order 6 octet (xx) from a unique IEEE          -- assigned address.  The high order two bits of the IEEE          -- address, the group address bit and the administration bit          -- (Universal/Local) bit should both be zero.  The first two          -- octets, the yy octets, are implementor-defined.          --          -- The representation of the address portion of the station id          -- is in the IEEE (ANSI/IEEE P802.1A) canonical notation for          -- 48 bit addresses.  The canonical form is a 6-octet string          -- where the first octet contains the first 8 bits of the          -- address, with the I/G(Individual/Group) address bit as the          -- least significant bit and the  U/L (Universal/Local) bit          -- as the next more significant bit, and so on.  Note that          -- addresses in the ANSI FDDI standard SMT frames are          -- represented in FDDI MAC order.          FddiMACLongAddressType ::= OCTET STRING (SIZE (6))          -- The representation of long MAC addresses as management          -- values is in the IEEE (ANSI/IEEE P802.1A) canonical          -- notation for 48 bit addresses.  The canonical form is a          -- 6-octet string where the first octet contains the first 8          -- bits of the address, with the I/G (Individual/Group)          -- address bit as the least significant bit and the  U/L          -- (Universal/Local) bit as the next more significant bit,          -- and so on.  Note that the addresses in the SMT frames are          -- represented in FDDI MAC order.          -- groups in the FDDI MIB module          fddimibSMT          OBJECT IDENTIFIER ::= { fddimib 1 }          fddimibMAC          OBJECT IDENTIFIER ::= { fddimib 2 }          fddimibMACCounters  OBJECT IDENTIFIER ::= { fddimib 3 }          fddimibPATH         OBJECT IDENTIFIER ::= { fddimib 4 }          fddimibPORT         OBJECT IDENTIFIER ::= { fddimib 5 }          -- the SMT group          -- Implementation of the SMT group is mandatory for all          -- systems which implement manageable FDDI subsystems.          fddimibSMTNumber OBJECT-TYPE              SYNTAX  INTEGER (0..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The number of SMT implementations (regardless of                      their current state) on this network management                      application entity.  The value for this variable                      must remain constant at least from one re-                      initialization of the entity's network management                      system to the next re-initialization."              ::= { fddimibSMT  1 }          -- the SMT table          fddimibSMTTable OBJECT-TYPE              SYNTAX  SEQUENCE OF FddimibSMTEntry              ACCESS  not-accessible              STATUS  mandatory              DESCRIPTION                      "A list of SMT entries.  The number of entries                      shall not exceed the value of fddimibSMTNumber."              ::= { fddimibSMT  2 }          fddimibSMTEntry OBJECT-TYPE              SYNTAX  FddimibSMTEntry              ACCESS  not-accessible              STATUS  mandatory              DESCRIPTION                      "An SMT entry containing information common to a                      given SMT."              INDEX   { fddimibSMTIndex }              ::= { fddimibSMTTable 1 }          FddimibSMTEntry ::=              SEQUENCE {                  fddimibSMTIndex                      INTEGER,                  fddimibSMTStationId                      FddiSMTStationIdType,                  fddimibSMTOpVersionId                      INTEGER,                  fddimibSMTHiVersionId                      INTEGER,                  fddimibSMTLoVersionId                      INTEGER,                  fddimibSMTUserData                      OCTET STRING,                  fddimibSMTMIBVersionId                      INTEGER,                  fddimibSMTMACCts                      INTEGER,                  fddimibSMTNonMasterCts                      INTEGER,                  fddimibSMTMasterCts                      INTEGER,                  fddimibSMTAvailablePaths                      INTEGER,                  fddimibSMTConfigCapabilities                      INTEGER,                  fddimibSMTConfigPolicy                      INTEGER,                  fddimibSMTConnectionPolicy                      INTEGER,                  fddimibSMTTNotify                      INTEGER,                  fddimibSMTStatRptPolicy                      INTEGER,                  fddimibSMTTraceMaxExpiration                      FddiTimeMilli,                  fddimibSMTBypassPresent                      INTEGER,                  fddimibSMTECMState                      INTEGER,                  fddimibSMTCFState                      INTEGER,                  fddimibSMTRemoteDisconnectFlag                      INTEGER,                  fddimibSMTStationStatus                      INTEGER,                  fddimibSMTPeerWrapFlag                      INTEGER,                  fddimibSMTTimeStamp                      FddiTimeMilli,                  fddimibSMTTransitionTimeStamp                      FddiTimeMilli,                  fddimibSMTStationAction                      INTEGER              }          fddimibSMTIndex OBJECT-TYPE              SYNTAX  INTEGER (1..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "A unique value for each SMT.  The value for each                      SMT must remain constant at least from one re-                      initialization of the entity's network management                      system to the next re-initialization."              ::= { fddimibSMTEntry 1 }          fddimibSMTStationId OBJECT-TYPE              SYNTAX  FddiSMTStationIdType -- OCTET STRING (SIZE (8))              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "Used to uniquely identify an FDDI station."              REFERENCE                      "ANSI { fddiSMT 11 }"              ::= { fddimibSMTEntry 2 }          fddimibSMTOpVersionId OBJECT-TYPE              SYNTAX  INTEGER (1..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The version that this station is using for its                      operation (refer to ANSI 7.1.2.2). The value of                      this variable is 2 for this SMT revision."              REFERENCE                      "ANSI { fddiSMT 13 }"              ::= { fddimibSMTEntry 3 }          fddimibSMTHiVersionId OBJECT-TYPE              SYNTAX  INTEGER (1..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The highest version of SMT that this station                      supports (refer to ANSI 7.1.2.2)."              REFERENCE                      "ANSI { fddiSMT 14 }"              ::= { fddimibSMTEntry 4 }          fddimibSMTLoVersionId OBJECT-TYPE              SYNTAX  INTEGER (1..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The lowest version of SMT that this station                      supports (refer to ANSI 7.1.2.2)."              REFERENCE                      "ANSI { fddiSMT 15 }"              ::= { fddimibSMTEntry 5 }          fddimibSMTUserData OBJECT-TYPE              SYNTAX  OCTET STRING (SIZE (32))              ACCESS  read-write              STATUS  mandatory              DESCRIPTION                      "This variable contains 32 octets of user defined                      information. The information shall be an ASCII                      string."              REFERENCE                      "ANSI { fddiSMT 17 }"              ::= { fddimibSMTEntry 6 }          fddimibSMTMIBVersionId OBJECT-TYPE              SYNTAX  INTEGER (0..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The version of the FDDI MIB of this station.  The                      value of this variable is 1 for this SMT                      revision."              REFERENCE                      "ANSI { fddiSMT 18 }"              ::= { fddimibSMTEntry 7 }          fddimibSMTMACCts OBJECT-TYPE              SYNTAX  INTEGER (0..255)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The number of MACs in this station or                      concentrator."              REFERENCE                      "ANSI { fddiSMT 21 }"              ::= { fddimibSMTEntry 8 }          fddimibSMTNonMasterCts OBJECT-TYPE              SYNTAX  INTEGER (0..2)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The value of this variable is the number of A, B,                      and S ports in this station or concentrator."              REFERENCE                      "ANSI { fddiSMT 22 }"              ::= { fddimibSMTEntry 9 }          fddimibSMTMasterCts OBJECT-TYPE              SYNTAX  INTEGER (0..255)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The number of M Ports in a node. If the node is                      not a concentrator, the value of the variable is                      zero."              REFERENCE                      "ANSI { fddiSMT 23 }"              ::= { fddimibSMTEntry 10 }          fddimibSMTAvailablePaths OBJECT-TYPE              SYNTAX  INTEGER (0..7)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "A value that indicates the PATH types available                      in the station.

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -