📄 trafficlight.fit.rpt
字号:
+--------------------------------------------+------------------------------+
; Number of Logic Elements (Average = 5.85) ; Number of LABs (Total = 26) ;
+--------------------------------------------+------------------------------+
; 1 ; 10 ;
; 2 ; 1 ;
; 3 ; 0 ;
; 4 ; 1 ;
; 5 ; 0 ;
; 6 ; 0 ;
; 7 ; 0 ;
; 8 ; 2 ;
; 9 ; 0 ;
; 10 ; 12 ;
+--------------------------------------------+------------------------------+
+-------------------------------------------------------------------+
; LAB-wide Signals ;
+------------------------------------+------------------------------+
; LAB-wide Signals (Average = 0.88) ; Number of LABs (Total = 26) ;
+------------------------------------+------------------------------+
; 1 Clock ; 14 ;
; 1 Clock enable ; 1 ;
; 1 Sync. clear ; 8 ;
+------------------------------------+------------------------------+
+----------------------------------------------------------------------------+
; LAB Signals Sourced ;
+---------------------------------------------+------------------------------+
; Number of Signals Sourced (Average = 5.88) ; Number of LABs (Total = 26) ;
+---------------------------------------------+------------------------------+
; 0 ; 0 ;
; 1 ; 10 ;
; 2 ; 1 ;
; 3 ; 0 ;
; 4 ; 1 ;
; 5 ; 0 ;
; 6 ; 0 ;
; 7 ; 0 ;
; 8 ; 2 ;
; 9 ; 1 ;
; 10 ; 9 ;
; 11 ; 2 ;
+---------------------------------------------+------------------------------+
+--------------------------------------------------------------------------------+
; LAB Signals Sourced Out ;
+-------------------------------------------------+------------------------------+
; Number of Signals Sourced Out (Average = 4.42) ; Number of LABs (Total = 26) ;
+-------------------------------------------------+------------------------------+
; 0 ; 0 ;
; 1 ; 10 ;
; 2 ; 2 ;
; 3 ; 1 ;
; 4 ; 2 ;
; 5 ; 0 ;
; 6 ; 2 ;
; 7 ; 2 ;
; 8 ; 3 ;
; 9 ; 0 ;
; 10 ; 4 ;
+-------------------------------------------------+------------------------------+
+----------------------------------------------------------------------------+
; LAB Distinct Inputs ;
+---------------------------------------------+------------------------------+
; Number of Distinct Inputs (Average = 5.58) ; Number of LABs (Total = 26) ;
+---------------------------------------------+------------------------------+
; 0 ; 0 ;
; 1 ; 0 ;
; 2 ; 2 ;
; 3 ; 5 ;
; 4 ; 10 ;
; 5 ; 1 ;
; 6 ; 0 ;
; 7 ; 0 ;
; 8 ; 3 ;
; 9 ; 0 ;
; 10 ; 1 ;
; 11 ; 2 ;
; 12 ; 1 ;
; 13 ; 1 ;
+---------------------------------------------+------------------------------+
+-----------------+
; Fitter Messages ;
+-----------------+
Info: *******************************************************************
Info: Running Quartus II Fitter
Info: Version 4.2 Build 157 12/07/2004 SJ Full Version
Info: Processing started: Sun May 28 11:10:06 2006
Info: Command: quartus_fit --import_settings_files=off --export_settings_files=off trafficlight -c trafficlight
Info: Automatically selected device EP1C3T100C6 for design trafficlight
Info: Fitter is performing an Auto Fit compilation, which may decrease Fitter effort to reduce compilation time
Info: Device migration not selected. If you intend to use device migration later, you may need to change the pin assignments as they may be incompatible with other devices.
Info: No exact pin location assignment(s) for 19 pins of 19 total pins
Info: Pin Red1 not assigned to an exact location on the device
Info: Pin Red2 not assigned to an exact location on the device
Info: Pin Yellow1 not assigned to an exact location on the device
Info: Pin Yellow2 not assigned to an exact location on the device
Info: Pin Green1 not assigned to an exact location on the device
Info: Pin Green2 not assigned to an exact location on the device
Info: Pin SEG_Data[7] not assigned to an exact location on the device
Info: Pin SEG_Data[6] not assigned to an exact location on the device
Info: Pin SEG_Data[5] not assigned to an exact location on the device
Info: Pin SEG_Data[4] not assigned to an exact location on the device
Info: Pin SEG_Data[3] not assigned to an exact location on the device
Info: Pin SEG_Data[2] not assigned to an exact location on the device
Info: Pin SEG_Data[1] not assigned to an exact location on the device
Info: Pin SEG_Data[0] not assigned to an exact location on the device
Info: Pin SEG_Sel[1] not assigned to an exact location on the device
Info: Pin SEG_Sel[0] not assigned to an exact location on the device
Info: Pin Reset not assigned to an exact location on the device
Info: Pin SW not assigned to an exact location on the device
Info: Pin CLK not assigned to an exact location on the device
Info: Timing requirements not specified -- optimizing circuit to achieve the following default global requirements
Info: Assuming a global fmax requirement of 1 MHz
Info: Not setting a global tsu requirement
Info: Not setting a global tco requirement
Info: Not setting a global tpd requirement
Info: Performing register packing on registers with non-logic cell location assignments
Info: Completed register packing on registers with non-logic cell location assignments
Info: Completed User Assigned Global Signals Promotion Operation
Info: Automatically promoted signal "CLK" to use Global clock in PIN 10
Info: Automatically promoted signal "fdiv1khz:inst12|clk_out" to use Global clock
Info: Automatically promoted signal "fdiv1hz:inst11|clk_out" to use Global clock
Info: Automatically promoted signal "scan:inst|EN_in" to use Global clock
Info: Completed Auto Global Promotion Operation
Info: Starting register packing
Info: Started Fast Input/Output/OE register processing
Info: Finished Fast Input/Output/OE register processing
Info: Fitter is using Normal packing mode for logic elements with Auto setting for Auto Packed Registers logic option
Info: Mov
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -