22. Proceed to step 25 if the displayed I/O port address is the same with one
    which you decided previously.

23. Click [Change Setting] button.
        [Edit Input/Output Range] window is displayed.

24. Change [Value] with new address which you decided previously, then click
    [OK] button.

25. Click [OK] button.
        [System Setting Change] window is displayed, and "Do you want to
        shut down your computer now?" message is displayed.

26. If you install the driver for the next HSSB interface board, click [No]
    button and go back to step 3.

    If the installation on all the HSSB interface boards finishes,
    click [Yes] button.

 (Note) Differ from 16 bit version of driver, this driver does not require
        those 16 bit drivers.  If there are drivers of previous version
        (such as HSSBSYS.EXE, ITSYS.EXE, NCBOOT.EXE) in CONFIG.SYS or
        AUTOEXEC.BAT, they are removed automatically on the installation.

        If the NCALARM.EXE is registered to the startup folder, please
        delete it manually.

==========================================================================
[3] Installation (Windows NT)
==========================================================================

 (Note) The FS300i/310i/320i is not supported by the HSSB driver for
        Windows NT.

    In case of HSSB multi-connection, determine the kind  of the HSSB
    interface board (ISA/PCI) used by each node and correspondence between
    nodes and connected CNCs.
    Next, do the following according to the kind of the HSSB interface board.

     - For the ISA HSSB interface board
       Decide the I/O port address to be allocated on the HSSB board and
       set the rotary switch of the HSSB board. (In case of PC integrated type
       i-series, Intelligent Terminal type 2 which do not have the ISA
       extension unit, I/O port address is fixed at 280H-28BH.)

     - For the PCI HSSB interface board
       Nothing need to be done. (The I/O port address is automatically set
       by the HSSB driver. FANUC PANEL i and CNC Display Unit with Personal
       Computer Function are also included in this case.)

    When two or more PCI HSSB interface boards are installed, the nodes are
    allotted first from the PCI HSSB interface board inserted in lower PCI
    slot number.


    To install the HSSB driver to your system, use the Windows NT Explorer.
    The installation procedure of the driver is as follows.

 1. Logon to the Windows NT as the Administrator.

 2. Close all application programs. You must close the Control Panel if it
    is running.

 3. Run the Windows NT Explorer.

 4. Set this CD onto the CD-ROM drive and open \Hssb\Nt40 folder at CD-ROM by
    the Windows NT Explorer.

 5. Right-click the HSSB.INF file and click [install] on the pop up menu.
        Installer will copy driver files and register them to the registry.

    Next, setup HSSB driver by the Control Panel. Remove the CD from the
    CD-ROM drive.

 6. Run the Control Panel and double-click the HSSB icon.

 7. Select the node number that you want to attach the HSSB board and click
    [Setting...] button.

 8. Enter proper name which indicates the machine connected to the HSSB board
    (for example, "FS160 - No.1", "Milling Machine") to [Node name] within 19
    characters.

 9. Select CNC type from the [CNC Type] list box.

10. Select I/O port address according to the kind of the HSSB board.
     - For the ISA HSSB interface board
       Select I/O port address that correspond to the rotary switch on
       the HSSB board, from the [I/O Port Address] list box.

     - For the PCI HSSB interface board
       Select the [Use PCI] from the [I/O Port Address] list box.
       (The I/O port address is automatically set by the driver.)

11. Click [OK] button to close this window.

12. In case of multiple HSSB connection, go back to step 7. and repeat these
    steps for each HSSB board.

    If a node is not attached to HSSB board, select "Disable" from the
    [I/O Port Address] list box.

    After driver installation, I/O port address is set to 0x280 for node-0,
    "Disable" for other nodes as default value.

13. Click [Close] button.
        A dialogue window which asks you to restart Windows, will open.

14. Click [YES] button to restart Windows NT.


 (Note) To change HSSB driver setting, you must have the Administrator
        privilege.


==========================================================================
[4] Installation (Windows 2000)
==========================================================================

    In case of HSSB multi-connection, determine the kind of the HSSB
    interface board (ISA/PCI) used by each node and correspondence between
    nodes and connected CNCs.
    Next, do the following according to the kind of the HSSB interface board.

     - For the ISA HSSB interface board
       Decide the I/O port address to be allocated on the HSSB board and
       set the rotary switch of the HSSB board. (In case of PC integrated type
       i-series, Intelligent Terminal type 2 which do not have the ISA
       extension unit, I/O port address is fixed at 280H-28BH.)

     - For the PCI HSSB interface board
       Nothing need to be done. (The I/O port address is automatically set
       by the HSSB driver. FANUC PANEL i and CNC Display Unit with Personal
       Computer Function are also included in this case.)

    When two or more PCI HSSB interface boards are installed, the nodes are
    allotted first from the PCI HSSB interface board inserted in lower PCI
    slot number.


    To install the HSSB driver to your system, use the "Found New Hardware
    Wizard" or "Add/Remove Hardware".
    There are following two methods of installation procedures for the driver.

        A.  Method by the automatic detection by Windows (Only for PCI HSSB 
            interface board)
        B.  Method by the manual operation

-------------------------------------------------------------------------------
 A.  Method by the automatic detection by Windows (Only for PCI HSSB interface
     board)

 1. When Windows is started, the PCI HSSB interface board is detected as "PCI
    Simple Communications Controller".
        [Found New Hardware Wizard] window is displayed.

     (When the PCI HSSB interface board is not detected automatically by
      Windows, install the driver according to following procedure,
     "B. Method by the manual operation".)

 2. Click [Next] button.
        [Install Hardware Device Drivers] screen is displayed.

 3. Select "Search for a suitable driver for my device(recommended)" 
    and click [Next] button.
        [Locate Driver Files] screen is displayed.

 4. Set this CD onto the CD-ROM drive.
    Check only "Specify a location" of Optional search locations, then
    click [Next] button.

 5. Enter "d:\hssb\win2k" on [Copy manufacturer's files from] box, then 
    click [OK] button.("d:" is the drive letter for the CD-ROM.  If other
    drive letter is assigned to your drive, change it properly.)

 6. The following message is displayed on [Driver Files Search Results].
    Click [Next] button.

        Windows found a driver for this device. To install the driver 
        Windows found, click Next.
            d:\hssb\win2k\hssb.inf

 7. Click [Next] button.
        Files are copied.

 8. [Completing the Found New Hardware Wizard] is displayed.
    Click [Finish] button.

         The installation is automatically done if there are two or more PCI
        HSSB interface boards.

    Next, setup HSSB driver by the Control Panel. Remove this CD from the
    CD-ROM drive.

 9. Run the Control Panel and double-click the HSSB icon.

10. Select the node number that you want to attach the HSSB board and click
    [Setting...] button.

11. Enter proper name which indicates the machine connected to the HSSB board
    (for example, "FS160 - No.1", "Milling Machine") to [Node name] within 19
    characters.

12. Select CNC type from the [CNC Type] list box.

13. Click [OK] button to close this window.

14. In case of multiple HSSB connection, go back to step 10. and repeat these
    steps for each HSSB board.

15. Click [Close] button.
        A dialogue window which asks you to restart Windows, will open.

16. Click [Yes] button to restart Windows 2000.


-------------------------------------------------------------------------------
 B. Method by the manual operation

 1. Click [Start] button.
        [Start] menu is displayed.

 2. Point [Setting], then click [Control Panel].
        [Control Panel] window is displayed.

 3. Double-click [Add/Remove Hardware].
        [Welcome to the Add/Remove Hardware Wizard] screen of [Add/Remove
        Hardware Wizard] window is displayed.

 4. Click [Next] button.
        [Choose a Hardware Task] screen is displayed.

 5. Select "Add/Troubleshoot a device", then click [Next] button.
        [Choose a Hardware Device] screen is displayed.

 6. Click [Add a new device] from [Devices] list box, then click [Next]
    button.
        [Find New Hardware] screen is displayed, then following message is
        displayed.
            Do you want Windows to search for your new hardware?

 7. Select "No, I want to select the hardware from a list", then click
    [Next] button.
        [Hardware Type] screen is displayed.

 8. When the item of [FANUC Open CNC] is not displayed on [Hardware types]
    list box, click [Other devices], then click [Next] button.
        [Select a Device Driver] screen is displayed.

    When the item of [FANUC Open CNC] is displayed on [Hardware types] list
    box, click [FANUC Open CNC], then click [Next] button.
    Proceed to step 11.

 9. Click [Have Disk...] button, then set this CD onto the CD-ROM drive.

10. Enter "d:\hssb\win2k" on [Copy manufacturer's files from] box, then
    click [OK] button.  ("d:" is the drive letter for the CD-ROM.  If other
    drive letter is assigned to your drive, change it properly.)

11. [Select a Device Driver] screen is displayed.
        The following [Models] list box is displayed.
          FANUC HSSB Type 2 (ISA 1 Channel)
          FANUC HSSB Type 2 (ISA 2 Channel)
          FANUC HSSB Type 2 (PCI 1 Channel)
          FANUC HSSB Type 2 (PCI 2 Channel)
          FANUC HSSB3 (PCI 1 Channel)
          FANUC HSSB3 (PCI 2 Channel)

12. Click the item corresponding to the HSSB interface board which should be
    used.
    In case of PC integrated type i-series, Intelligent Terminal type 2, select
    "FANUC HSSB Type 2 (ISA 1 Channel)".
    In case of FANUC PANEL i and CNC Display Unit with Personal Computer
    Function, select "FANUC HSSB Type 2 (PCI 1 Channel)".
    In case of FS30i, select "FANUC HSSB3 (PCI 1 Channel)".

13. Click [Next] button.

14. The following message is displayed by [Add/Remove Hardware Wizard].

        Windows could not detect the settings of the device. To use this
        device, you must enter its hardware settings. Consult the 
        documentation that came with this device for information.

15. Click [OK] button.
        [Add New hardware Wizard Properties] window is displayed.

16. Click [Input/output Range] of [Resource settings] list box, then click
    [Change Setting...]  button.
        [Edit Input/Output Range] window is displayed.

17. Change the Input/Oouput Range displayed  in "Value" box with one which
    you decided previously, then click [OK] button.
        Return to [Add New Hardware Wizard Properties] screen.

18. Click [OK] button.
        [Start hardwareInstallation] screen is displayed.

19. Click [Next] button.
        After copying files from the floppy disk, [Completing the Add/remove
        Hardware Wizard] screen is displayed.

20. Click [Finish] button.
        [System Setting Change] window is displayed, then the following
        message is displayed.

            You must restart your computer before the new settings will take
            effect. Do you want to restart your computer now?

21. Click [Yes] button to restart Windows 2000.


    Next, setup HSSB driver by the Control Panel. Remove this CD from the
    CD-ROM drive.

22. Run the Control Panel and double-click the HSSB icon.

23. Select the node number that you want to attach the HSSB board and click
    [Setting...] button.

24. Enter proper name which indicates the machine connected to the HSSB board
    (for example, "FS160 - No.1", "Milling Machine") to [Node name] within 19
    characters.

25. Select CNC type from the [CNC Type] list box.

26. Click [OK] button to close this window.

27. In case of multiple HSSB connection, go back to step 10. and repeat these
    steps for each HSSB board.

28. Click [Close] button.
        A dialogue window which asks you to restart Windows, will open.