⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 cim_protocolcontrollermaskingcapabilities.mof

📁 Pegasus is an open-source implementationof the DMTF CIM and WBEM standards. It is designed to be por
💻 MOF
字号:
// Copyright (c) 2005 DMTF.  All rights reserved.// <change cr="DMTFCR01492.001" type ="add">Added SPCAllowsNoLUs,// SPCAllowsNoTargets, SPCAllowsNoInitiators, SPCSupportsDefaultViews.</// <change cr="CIMCoreCR00820.003" type ="change">Remove Experimental// from properties.</change>// <change cr="ArchCR00066.004" type="add">Add UmlPackagePath// qualifier values to CIM Schema.</change>// ==================================================================//  CIM_ProtocolControllerMaskingCapabilities// ==================================================================   [UMLPackagePath ( "CIM::Device::ProtocolController" ),       Version ( "2.10.0" ), Description (       "A subclass of Capabilities that defines the Masking-related "       "capabilities of a ProtocolController.")]class CIM_ProtocolControllerMaskingCapabilities : CIM_Capabilities {      [Description (          "A list of the valid values for StrorageHardwareID.IDType. "          "iSCSI IDs MAY use one of three iSCSI formats - iqn, eui, or "          "naa. This three letter format is the name prefix; so a "          "single iSCSI type is provided here, the prefix can be used "          "to further refine the format."),        ValueMap { "1", "2", "3", "4", "5" },        Values { "Other", "Port WWN", "Node WWN", "Host Name",          "iSCSI Name" }, ArrayType ( "Indexed" )]   uint16 ValidHardwareIdTypes[];      [Description (          "An array of strings describing types for valid "          "StorageHardwareID.IDType. Used when the "          "ValidHardwareIdTypes includes 1 (\"Other\")."),        ArrayType ( "Indexed" )]   string OtherValidHardwareIDTypes[];      [Description (          "An integer enumeration indicating the way that ports per "          "view (ProtocolController) are handled by the underlying "          "storage system."),        ValueMap { "2", "3", "4" },        Values { "One Port per View", "Multiple Ports per View",          "All Ports share the same View" }]   uint16 PortsPerView = 2;      [Description (          "Set to true if this storage system allows the client to "          "specify the DeviceNumber parameter when calling "          "ControllerConfigurationService.AttachDevice() or specify "          "the DeviceNumbers parameter when calling "          "ControllerConfigurationService.ExposePaths(). Set to false "          "if the implementation does not allow unit numbers to vary "          "for a ProtocolController. However, if set to false and a "          "Device is not the Dependent of a ProtocolControllerForUnit "          "association, the client MUST provide a DeviceNumber "          "parameter in ControllerConfigurationService.AttachDevice or "          "ControllerConfigurationService.ExposePaths. If set to false "          "and the Device is already the Dependent of a "          "ProtocolControllerForUnit association, then the client can "          "omit the DeviceNumber parameter (or supply the same value) "          "in subsequent ControllerConfigurationService.AttachDevice "          "calls.")]   boolean ClientSelectableDeviceNumbers = TRUE;      [Description (          "Set to true if this storage system supports the "          "AttachDevice method.")]   boolean AttachDeviceSupported;      [Description (          "Set to true if this storage system limits configurations to "          "a single subject hardware ID per view. Otherwise, multiple "          "hardware ID types can be used. The default is FALSE, that "          "multiple ID types MAY be used in a single view.")]   boolean OneHardwareIDPerView = FALSE;      [Description (          "When set to false, different ProtocolContollers attached to "          "a LogicalPort can expose the same unit numbers. If true, "          "then this storage system requires unique unit numbers "          "across all the ProtocolControllers connected to a "          "LogicalPort.")]   boolean UniqueUnitNumbersPerPort = FALSE;      [Description (          "Set to true if this storage system allows a client to "          "create a Privilege instance with PrivilegeGranted set to "          "FALSE.")]   boolean PrivilegeDeniedSupported = FALSE;      [Description (          "If true, this property indicates that a Privilege/Identity "          "pair MUST be specified when "          "CreateProtocolControllerWithPorts() is called. If false, "          "then the Privilege/Identity pair in "          "CreateProtocolControllerWithPorts() MUST NOT be set.")]   boolean ProtocolControllerRequiresAuthorizedIdentity = FALSE;      [Description (          "If true, this property indicates that the Identity "          "parameter of CreateProtocolConntrollerWithPorts() MUST "          "contain a reference to a CIM_Collection (or subclass) or to "          "a CIM_Identity (or subclass). If ExposePathsSupported is "          "true, this property indicates the storage system supports "          "SystemSpecificCollections of StorageHardwareIDs.")]   boolean ProtocolControllerSupportsCollections = FALSE;      [Description (          "Set to true if this storage system supports the ExposePaths "          "and HidePaths methods.")]   boolean ExposePathsSupported;      [Description (          "Set to true if this storage system supports the "          "CreateProtocolControllerWithPorts method.")]   boolean CreateProtocolControllerSupported;      [Description (          "The maximum number of ProtocolCOntrollerForUnit "          "associations that can be associated with a single "          "LogicalDevice (for example, StorageVolume). Zero indicates "          "there is no limit.")]   uint16 MaximumMapCount = 0;      [Description (          "Set to true if the instumentation allows a client to create "          "a configuration where an SPC has no LogicalDevices "          "associated via CIM_ProtocolControllerForUnit associations.")]   boolean SPCAllowsNoLUs = FALSE;      [Description (          "Set to true if the instumentation allows a client to create "          "a configuration where an SPC has no target "          "SCSIProtocolEndpoints associated via "          "CIM_SAPAvailableForELement associations.")]   boolean SPCAllowsNoTargets = FALSE;      [Description (          "Set to true if the instumentation allows a client to create "          "a configuration where an SPC has no StorageHardwareIDs "          "associated via "          "CIM_AuthorizedTarget/CIM_AuthorizedPrivilege/CIM_AuthorizedSubject.")]   boolean SPCAllowsNoInitiators = FALSE;      [Description (          "Set to true if it the instrumentation supports 'default "          "view' SPCs that exposes logical units to all initiators (so "          "called 'promiscuous LUNs'. Default view SPCs MUST have be "          "associated to a CIM_StorageHardwareID instance with Name "          "set to the null string. A target port MUST NOT be "          "associated with more a single default view SPC. If "          "PortsPerView is 'All Ports share the same View', then at "          "most one default view SPC MAY be associated with the target "          "system. If SPCAllowsNoLUs is true, the instrumentation MAY "          "instantiate a static default view instance or let the "          "client create one as needed using ExposePaths. For other "          "values of PortsPerView, all default view SPC MUST share the "          "same null-Name CIM_StorageHardwareID instance."),        ModelCorrespondence {           "CIM_ProtocolControllerMaskingCapabilities.PortsPerView" }]   boolean SPCSupportsDefaultViews = TRUE;};

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -