⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 cim_setting.mof

📁 Pegasus is an open-source implementationof the DMTF CIM and WBEM standards. It is designed to be por
💻 MOF
📖 第 1 页 / 共 2 页
字号:
          "parameters: MSE (the ManagedSystemElement that is being "          "verified), TimeToApply (which, being a datetime, can be "          "either a specific time or a time interval), "          "MustBeCompletedBy (which indicates the required completion "          "time for the method), and a PropertiesToApply array (which "          "contains a list of the property names whose values will be "          "verified). If the array is null or empty or contains the "          "string \"ALL\" as a property name, then all Settings "          "properties will be verified. If it is set to \"NONE\", then "          "no Settings properties will be verified. The return value "          "should be 0 if it is okay to apply the Setting, 1 if the "          "method is not supported, 2 if the Setting cannot be applied "          "within the specified times, and any other number if an "          "error occurred. In a subclass, the set of possible return "          "codes could be specified using a ValueMap qualifier on the "          "method. The strings to which the ValueMap contents are "          "\"translated\" can also be specified in the subclass as a "          "Values array qualifier.")]   uint32 VerifyOKToApplyIncrementalChangeToMSE(          [IN, Description (             "The ManagedSystemElement for which the Setting is being "             "verified.")]      CIM_ManagedSystemElement REF MSE,          [IN, Description (             "TimeToApply can be either a specific time or a time "             "interval.")]      datetime TimeToApply,          [IN, Description (             "The required completion time for the method.")]      datetime MustBeCompletedBy,          [IN, Description (             "A list of the property names whose values will be "             "verified.")]      string PropertiesToApply[]);       [Description (          "The ApplyIncrementalChangeToMSE method performs the actual "          "application of a subset of the properties in the Setting to "          "the referenced ManagedSystemElement. It takes four input "          "parameters: MSE (the ManagedSystem Element to which the "          "Setting is being applied), TimeToApply (which, being a "          "datetime, can be either a specific time or a time "          "interval), MustBeCompletedBy (which indicates the required "          "completion time for the method), and a PropertiesToApply "          "array (which contains a list of the property names whose "          "values will be applied). If a property is not in this list, "          "it will be ignored by the Apply. If the array is null, "          "empty, or contains the string \"ALL\" as a property name, "          "then all Settings properties will be applied. If it is set "          "to \"NONE\", then no Settings properties will be applied. \n"          "Note that the semantics of this method are that individual "          "Settings are either wholly applied or not applied at all to "          "their target ManagedSystemElement. The return value should "          "be 0 if the Setting is successfully applied to the "          "referenced ManagedSystemElement, 1 if the method is not "          "supported, 2 if the Setting was not applied within the "          "specified times, and any other number if an error occurred. "          "In a subclass, the set of possible return codes could be "          "specified using a ValueMap qualifier on the method. The "          "strings to which the ValueMap contents are \"translated\" "          "can also be specified in the subclass as a Values array "          "qualifier. \n"          "Note: If an error occurs when applying the Setting to a "          "ManagedSystemElement, the Element must be configured as it "          "was when the \"Apply\" attempt began. That is, the Element "          "should not be left in an indeterminate state.")]   uint32 ApplyIncrementalChangeToMSE(          [IN, Description (             "The ManagedSystemElement to which the Setting is being "             "applied.")]      CIM_ManagedSystemElement REF MSE,          [IN, Description (             "TimeToApply can be either a specific time or a time "             "interval.")]      datetime TimeToApply,          [IN, Description (             "The required completion time for the method.")]      datetime MustBeCompletedBy,          [IN, Description (             "A list of the property names whose values will be "             "applied.")]      string PropertiesToApply[]);       [Description (          "The VerifyOKToApplyIncrementalChangeToCollection method is "          "used to verify that a subset of the properties in this "          "Setting can be applied to the referenced Collection of "          "ManagedSystemElements at the given time or time interval, "          "without causing adverse effects to either the Collection "          "itself or its surrounding environment. The net effect is to "          "execute the VerifyOKToApplyIncrementalChangeToMSE method "          "against each of the Elements that are aggregated by the "          "Collection. This method takes four input parameters: "          "Collection (the Collection of ManagedSystemElements that is "          "being verified), TimeToApply (which, being a datetime, can "          "be either a specific time or a time interval), "          "MustBeCompletedBy (which indicates the required completion "          "time for the method), and a PropertiesToApply array (which "          "contains a list of the property names whose values will be "          "verified). If the array is null or empty or contains the "          "string \"all\" as a property name, all Settings properties "          "will be verified. If it is set to \"none\" then no Settings "          "properties will be verified. The return value should be 0 "          "if it is okay to apply the Setting, 1 if the method is not "          "supported, 2 if the Setting cannot be applied within the "          "specified times, and any other number if an error occurred. "          "One output parameter, CanNotApply, is defined, which is a "          "string array that lists the keys of the "          "ManagedSystemElements to which the Setting cannot be "          "applied. This parameter enables those Elements to be "          "revisited and either fixed or have other corrective action "          "taken on them. \n"          "In a subclass, the set of possible return codes could be "          "specified using a ValueMap qualifier on the method. The "          "strings to which the ValueMap contents are \"translated\" "          "can also be specified in the subclass as a Values array "          "qualifier.")]   uint32 VerifyOKToApplyIncrementalChangeToCollection (          [IN, Description (             "The Collection of ManagedSystemElements for which the "             "setting is being verified.")]      CIM_CollectionOfMSEs REF Collection,          [IN, Description (             "TimeToApply can be either a specific time or a time "             "interval.")]      datetime TimeToApply,          [IN, Description (             "The required completion time for the method.")]      datetime MustBeCompletedBy,          [IN, Description (             "A list of the property names whose values will be "             "verified.")]      string PropertiesToApply[],          [IN ( false ), OUT, Description (             "A string array that lists the keys of the "             "ManagedSystemElements to which the Setting cannot be "             "applied.")]      string CanNotApply[]);       [Description (          "The ApplyIncrementalChangeToCollection method performs the "          "application of a subset of the properties in this Setting "          "to the referenced Collection of ManagedSystemElements. The "          "net effect is to execute the ApplyIncrementalChangeToMSE "          "method against each of the Elements that are aggregated by "          "the Collection. If the input value ContinueOnError is "          "false, this method applies the Setting to all Elements in "          "the Collection until it encounters an error, in which case "          "it stops execution, logs the key of the Element that caused "          "the error in the CanNotApply array, and issues a return "          "code of 2. If the input value ContinueOnError is true, then "          "this method applies the Setting to all of the "          "ManagedSystemElements in the Collection, and reports the "          "failed Elements in the array, CanNotApply. For the latter, "          "processing will continue until the method is applied to all "          "Elements in the Collection, regardless of any errors "          "encountered. The key of each ManagedSystemElement to which "          "the Setting could not be applied is logged into the "          "CanNotApply array. This method takes four input parameters: "          "Collection (the Collection of Elements to which the Setting "          "is being applied), TimeToApply (which, being a datetime, "          "can be either a specific time or a time interval), "          "ContinueOnError (true indicates to continue processing when "          "an error is encountered), MustBeCompletedBy (which "          "indicates the required completion time for the method), and "          "a PropertiesToApply array (which contains a list of the "          "property names whose values will be applied). If a property "          "is not in this list, it will be ignored by the Apply. If "          "the array is null or empty or contains the string \"ALL\" "          "as a property name, then all Settings properties will be "          "applied. If it is set to \"NONE\", then no Settings "          "properties will be applied. \n"          "The return value should be 0 if the Setting is successfully "          "applied to the referenced Collection, 1 if the method is "          "not supported, 2 if the Setting was not applied within the "          "specified time, 3 if the Setting cannot be applied using "          "the input value for ContinueOnError, and any other number "          "if an error occurred. One output parameter, "          "CanNotApplystring, is defined, which is an array that lists "          "the keys of the ManagedSystemElements to which the Setting "          "could not be applied. This output parameter has meaning "          "only when the ContinueOnError parameter is true. \n"          "In a subclass, the set of possible return codes could be "          "specified using a ValueMap qualifier on the method. The "          "strings to which the ValueMap contents are \"translated\" "          "can also be specified in the subclass as a Values array "          "qualifier. \n"          "Note: If an error occurs when applying the Setting to a "          "ManagedSystemElement in the Collection, the Element must be "          "configured as it was when the \"Apply\" attempt began. That "          "is, the Element should not be left in an indeterminate "          "state.")]   uint32 ApplyIncrementalChangeToCollection(          [IN, Description (             "The Collection of Elements to which the Setting is being "             "applied.")]      CIM_CollectionOfMSEs REF Collection,          [IN, Description (             "A specific time or a time interval.")]      datetime TimeToApply,          [IN, Description (             "True indicates to continue processing when an error is "             "encountered.")]      boolean ContinueOnError,          [IN, Description (             "This parameter indicates the required completion time "             "for the method.")]      datetime MustBeCompletedBy,          [IN, Description (             "A list of the property names whose values will be "             "verified.")]      string PropertiesToApply[],          [IN ( false ), OUT, Description (             "A string array that lists the keys of the "             "ManagedSystemElements to which the Setting cannot be "             "applied.")]      string CanNotApply[]); };

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -