📄 error.dat
字号:
0xD002:(D002) Parameter error: Illegal job variant.
0xD003:(D003) Parameter error: Debugging function not supported by module.
0xD004:(D004) Parameter error: Illegal job status.
0xD005:(D005) Parameter error: Illegal job termination.
0xD006:(D006) Parameter error: Illegal link disconnection ID.
0xD007:(D007) Parameter error: Illegal number of buffer elements.
0xD008:(D008) Parameter error: Illegal scan rate.
0xD009:(D009) Parameter error: Illegal number of executions.
0xD00A:(D00A) Parameter error: Illegal trigger event. Check whether the specified trigger is permitted on this module.
0xD00B:(D00B) Parameter error: Illegal trigger condition. Check whether the specified trigger is permitted on this module.
0xD011:(D011) Parameter error in path of the call environment: Block does not exist.
0xD012:(D012) Parameter error: Wrong address in block.
0xD014:(D014) Parameter error: Block being deleted/overwritten.
0xD015:(D015) Parameter error: Illegal variable address.
0xD016:(D016) Parameter error: Test jobs not possible, because of errors in user program.
0xD017:(D017) Parameter error: Illegal trigger number.
0xD025:(D025) Parameter error: Incorrect path.
0xD026:(D026) Parameter error: Incorrect access type.
0xD027:(D027) Parameter error: Invalid number of data blocks.
0xD031:(D031) Internal protocol error.
0xD032:(D032) Parameter error: Wrong result buffer length.
0xD033:(D033) Protocol error: Wrong job length.
0xD03F:(D03F) Coding error: Error in parameter section (for example, reserve bytes not equal to 0).
0xD041:(D041) Data error: Illegal status list ID.
0xD042:(D042) Data error: Illegal variable address.
0xD043:(D043) Data error: Referenced job not found, check job data.
0xD044:(D044) Data error: Illegal variable value, check job data.
0xD045:(D045) Data error: Leaving the BASP control (ODIS) is not allowed in HOLD.
0xD046:(D046) Data error: Illegal measuring stage during run-time measurement.
0xD047:(D047) Data error: Illegal hierarchy in 'Read job list'.
0xD048:(D048) Data error: Illegal deletion code in 'Delete job'.
0xD049:(D049) Invalid substitute ID in 'Replace job'.
0xD04A:(D04A) Error executing 'program status'.
0xD05F:(D05F) Coding error: Error in data section (for example, reserve bytes not equal to 0, ...).
0xD061:(D061) Resource error: No memory space for job.
0xD062:(D062) Resource error: Job list full.
0xD063:(D063) Resource error: Trigger event occupied.
0xD064:(D064) Resource error: Memory space too small for one result buffer element.
0xD065:(D065) Resource error: Memory space too small for a number of result buffer elements.
0xD066:(D066) Resource error: The timer available for run-time measurement is occupied by another job.
0xD067:(D067) Resource error: Too many 'modify variable' jobs active (including multi-processor operation).
0xD081:(D081) Function not permitted in current mode.
0xD082:(D082) Mode error: Cannot exit HOLD mode.
0xD0A1:(D0A1) Function not permitted in current protection level.
0xD0A2:(D0A2) Function not possible at present, because a memory-modifying function is running.
0xD0A3:(D0A3) Too many 'modify variable' jobs active on the I/O (including multi-processor operation).
0xD0A4:(D0A4) 'Forcing' has already been established.
0xD0A5:(D0A5) Referenced job not found.
0xD0A6:(D0A6) Job cannot be disabled/enabled.
0xD0A7:(D0A7) Job cannot be deleted because it is currently being read, for example. Try again.
0xD0A8:(D0A8) Job cannot be replaced because it is currently being read or deleted, for example. Try again.
0xD0A9:(D0A9) Job cannot be read because it is currently being deleted, for example. Try again.
0xD0AA:(D0AA) Time limit exceeded in processing operation.
0xD0AB:(D0AB) Invalid job parameters in process operation.
0xD0AC:(D0AC) Invalid job data in process operation.
0xD0AD:(D0AD) Operating mode already set.
0xD0AE:(D0AE) The job was set up over a different connection and can be handled over this connection.
0xD0C1:(D0C1) At least one error has been detected while accessing the variable(s).
0xD0C2:(D0C2) Mode transition to STOP/HOLD.
0xD0C3:(D0C3) At least one error has been detected while accessing the variable(s). Mode transition to STOP/HOLD.
0xD0C4:(D0C4) Time-out during run-time measurement.
0xD0C5:(D0C5) Display of block stack inconsistent, because blocks were deleted/reloaded.
0xD0C6:(D0C6) Job was automatically deleted as the jobs it referenced have been deleted.
0xD0C7:(D0C7) Job was automatically deleted because STOP mode was exited.
0xD0C8:(D0C8) 'Block status' aborted because of inconsistencies between test job and running program.
0xD0C9:(D0C9) Exit the status area by resetting OB90.
0xD0CA:(D0CA) Exit the status area by resetting OB90 and access error reading variables before exiting.
0xD0CB:(D0CB) The output disable for the peripheral outputs has been activated again.
0xD0CC:(D0CC) The number of data for the debugging functions is restricted by the time limit.
0xD201:(D201) Syntax error in block name.
0xD202:(D202) Syntax error in function parameters.
0xD205:(D205) Linked block already exists in RAM: Conditional copying is not possible.
0xD206:(D206) Linked block already exists in EPROM: Conditional copying is not possible.
0xD208:(D208) Maximum number of copied (not linked) blocks on module exceeded.
0xD209:(D209) (At least) one of the given blocks not found on the module.
0xD20A:(D20A) Maximum number of blocks linkable with a job exceeded.
0xD20B:(D20B) Maximum number of blocks deletable with a job exceeded.
0xD20C:(D20C) OB cannot be copied as the associated priority class does not exist.
0xD20D:(D20D) SDB cannot be interpreted (for example, unknown number).
0xD20E:(D20E) No (further) block available.
0xD20F:(D20F) Module-specific maximum block size exceeded.
0xD210:(D210) Invalid block number.
0xD212:(D212) Incorrect header attribute (run-time relevant).
0xD213:(D213) Too many SDBs. Note the restrictions on the module being used.
0xD216:(D216) Invalid user program - reset module.
0xD217:(D217) Protection level specified in module properties not permitted.
0xD218:(D218) Incorrect attribute (active/passive).
0xD219:(D219) Incorrect block lengths (for example, incorrect length of first section or of the whole block).
0xD21A:(D21A) Incorrect local data length or write-protection code faulty.
0xD21B:(D21B) Module cannot compress or compression was interrupted early. Note the restrictions on the module being used.
0xD21D:(D21D) The volume of dynamic project data transferred is illegal. It does not match the CPU configuration or the current user program. Check your settings and then save them again.
0xD21E:(D21E) Unable to assign parameters to a module (such as FM, CP). The system data could not be linked. For more information see the diagnostic buffer.
0xD220:(D220) Invalid programming language. Note the restrictions on the module being used.
0xD221:(D221) The system data for connections or routing are not valid. The clock parameters could have incorrect settings.
0xD222:(D222) The system data of the global data definition contain invalid parameters. Note the restrictions on the module being used and check your configuration.
0xD223:(D223) Error in instance data block for communication function block or maximum number of instance DBs exceeded. Check the programming and note the restrictions on the module being used.
0xD224:(D224) The SCAN system data block contains invalid parameters.
0xD225:(D225) The DP system data block contains invalid parameters.
0xD226:(D226) A structural error occurred in a block.
0xD230:(D230) A structural error occurred in a block.
0xD231:(D231) At least one loaded OB cannot be copied as the associated priority class does not exist.
0xD232:(D232) At least one block number of a loaded block is illegal.
0xD234:(D234) Block already exists in the given memory medium or in the job.
0xD235:(D235) The block contains an incorrect checksum.
0xD236:(D236) The block does not contain a checksum.
0xD237:(D237) You are about to load the block twice, i.e. a block with the same time stamp already exists on the CPU.
0xD238:(D238) At least one of the blocks specified is not a DB.
0xD239:(D239) At least one of the DBs specified is not available as a linked variant in the load memory.
0xD23A:(D23A) At least one of the DBs specified is considerably different from the copied and linked variant.
0xD240:(D240) Coordination rules violated.
0xD241:(D241) The function is not permitted in the current protection level.
0xD242:(D242) Protection violation while processing F blocks. F blocks can be processed only after a password has been entered. F block SDB99 cannot be deleted.
0xD250:(D250) Update and module ID or version do not match.
0xD251:(D251) Incorrect sequence of operating system components.
0xD252:(D252) Checksum error.
0xD253:(D253) No executable loader available; update only possible via memory card.
0xD254:(D254) Storage error in operating system.
0xD280:(D280) Error compiling block in S7-300 CPU.
0xD2A1:(D2A1) Another block function or a trigger on a block is active. Finish executing the other online function.
0xD2A2:(D2A2) A trigger is active on a block. Complete the debugging function first.
0xD2A3:(D2A3) The block is not activated (linked) or the block is about to be deleted. Repeat the function later.
0xD2A4:(D2A4) The block is already being processed via another block function. Repeat the function later.
0xD2A6:(D2A6) It is not possible to save and change the user program simultaneously. Repeat the function later.
0xD2A7:(D2A7) The block has the attribute 'unlinked' or is not being processed. It is not possible to carry out a debugging function for this block.
0xD2A8:(D2A8) A running debugging function is preventing parameters from being assigned to the CPU. Complete the debugging function first.
0xD2A9:(D2A9) New parameters are being assigned to the CPU. It is not possible to load the user program at the same time. Repeat the function later.
0xD2AA:(D2AA) New parameters are currently being assigned to the modules. Repeat the function later.
0xD2AB:(D2AB) The volume of dynamic project data is currently being changed. The user program is being re-evaluated. Wait until the system has finished re-evaluating, and then repeat your job.
0xD2AC:(D2AC) The requested changes cannot be activated while configuring in RUN (CiR), since running jobs are not terminated yet. Execute the function later.
0xD2B0:(D2B0) An error occurred while configuring in RUN (CiR). The changes requested are not valid.
0xD2C0:(D2C0) The number of technological objects has been exceeded. Reduce the number of amount of technological objects (axes, cam,...).
0xD2C1:(D2C1) The same technology data block already exists on the module
0xD2C2:(D2C2) Download user program or download hardware configuration is not possible, if Enable Peripheral Outputs is active. Exit Enable Peripheral Outputs before download.
0xD401:(D401) Information function unavailable.
0xD402:(D402) Information function unavailable.
0xD403:(D403) Service has already been logged on/off (Diagnostics/PMC).
0xD404:(D404) Maximum number of nodes reached. No more logons possible for diagnostics/PMC.
0xD405:(D405) Service not supported or syntax error in function parameters.
0xD406:(D406) Required information currently unavailable.
0xD407:(D407) Diagnostics error occurred.
0xD408:(D408) Update aborted.
0xD409:(D409) Error on DP bus.
0xD601:(D601) Syntax error in function parameter.
0xD602:(D602) Incorrect password entered.
0xD603:(D603) Link has already been legitimized.
0xD604:(D604) Link has already been enabled.
0xD605:(D605) Legitimization not possible as password does not exist.
0xD801:(D801) At least one variable address is invalid.
0xD802:(D802) Specified job does not exist.
0xD803:(D803) Illegal job status.
0xD804:(D804) Illegal cycle time (illegal time base or multiple).
0xD805:(D805) Additional cyclic read job cannot be set up.
0xD806:(D806) The referenced job is in a state in which the requested function cannot be performed.
0xD807:(D807) Function aborted due to overload, meaning executing the read cycle takes longer than the set scan cycle time.
0xDC01:(DC01) Error in date and/or time specification.
0xEF01:(EF01) S7 protocol error: Error at ID2. Only 00H permitted in job.
0xEF02:(EF02) S7 protocol error: Error at ID2. Set of resources does not exist.
0xFFFE:Error FFFE hex