📄 error.dat
字号:
0x0000:Success
0x0101:Connection not established / no parameters assigned
0x0112:Incorrect parameter
0x0113:Invalid block type.
0x0114:Block not found.
0x0115:Block already exists.
0x0116:Block is write-protected.
0x0117:The block is too large.
0x0118:Invalid block number.
0x0119:Incorrect password entered.
0x011A:PG resource error.
0x011B:PLC resource error.
0x011C:Internal error: Protocol error.
0x011D:Too many blocks (module-related restriction).
0x011E:No connection to database or S7DOS handle invalid.
0x011F:Result buffer too small
0x0120:End of block list.
0x0140:Insufficient memory available.
0x0141:Job cannot be processed because resources are missing.
0x0170:The simulator could not be found.
0x0180:The activated online function cannot be executed.
0x0181:Driver already open or too many open channels.
0x01C1:The field structure of the current database does not match the expected format.
0x01C3:The length specification in the block header does not match the actual length of a section in the database.
0x01C4:A problem occurred processing the last ID file.
0x01C5:Incorrect block format, the block does not have a valid PG format.
0x01C6:File not found.
0x01C7:Invalid operating system update components.
0x01C8:The database given as the destination already exists.
0x01C9:The database is already blocked by another application.
0x01CC:A DLL could not be loaded.
0x01CD:A function could not be found in the dynamically reloaded DLL.
0x01CF:File not found or access protection violation
0x01D0:Password not found.
0x01E0:Diagnostics not activated.
0x01E1:No diagnostic data are available.
0x01E2:The diagnostic data are inconsistent.
0x01F0:Function not implemented.
0x01FF:System error.
0x0312:Wrong configuration parameters
0x0315:MPI address error
0x0805:S7 protocol: Invalid flags.
0x0810:S7 protocol: The data could not be sent correctly.
0x0811:S7 protocol: No job found for the received data.
0x0D80:A diagnostic error occurred.
0x400A:The communications server could not be started.
0x400F:The connection to the communications server has been aborted.
0x401F:No such request in asynchronous list.
0x4020:No local memory available.
0x4021:The local memory cannot be locked.
0x4022:No reply to STEP 7 message frame.
0x4023:Messages are no longer executed by the CPU. The application does not react.
0x4060:Wrong Windows mode.
0x4061:No global memory.
0x4104:Online: No resources available in the driver.
0x4107:Online: Connection is closed.
0x4109:Online: No acknowledgment of the sending and receiving of data.
0x410E:Online: Connection aborted.
0x4110:Online: No connection established. No response from remote partner.
0x4114:Online: Connection already exists.
0x4116:Online: The connection to the target module cannot be established.
0x411A:Online: Illegal address.
0x411C:Online: Network error.
0x4201:Online: No resources available in the driver.
0x4211:Online: No other station with master capabilities could be found in the subnet.
0x4212:Online: Station not online.
0x4215:Online: Function not implemented or not permitted in current context.
0x4216:Online: Invalid DP slave station address or error message from DP slave.
0x4228:The bus parameters could not be automatically determined (online). There are no stations on the bus sending bus parameter message frames. Set the MPI/PROFIBUS interface manually.
0x4230:Online: No other active partner can be found.
0x4231:Online: Bus faulty.
0x4232:Online: Incorrect highest node address.
0x4233:Online: System error.
0x42A1:Online: Cannot initialize or open COM interface.
0x42B0:Online: Hardware not found.
0x42B1:Online: The local programming device interface is defective.
0x42B2:Online: Driver configuration error or invalid registry parameter.
0x42B3:Online: The local MPI address for the programming device/PC is higher than the maximum node address or the wrong transmission rate or wrong interrupt vector is set.
0x42B5:Online: The set local node address is already in use.
0x42B6:Online: The configured hardware interface is already being used by another programming package. Close all S7 applications and restart your programming package.
0x42B7:Online: The set interrupt vector (IRQ) is not available for this module.
0x42B8:Online: The set interrupt vector (IRQ) is already in use.
0x42C0:Online: Cannot load the selected communication driver; File not found.
0x42C1:Online: Function not implemented in loaded communication driver.
0x42C2:A connection between your PC/programming device and the PLC cannot be established.
0x42D0:Online: Incompatible adapter version or wrong adapter type connected.
0x42D1:Online: No interrupt received from PC/MPI cable.
0x42D2:Online: Communication link to the adapter damaged.
0x42D3:Online: COM port not configured under Windows.
0x42D4:Online: COM port currently not accessible.
0x42D5:Online: The serial driver is currently being used by an application with another configuration.
0x42D6:Online: The TS adapter interface is set up for a modem connection and there is no remote connection to a TS adapter.
0x42D7:Online: The TS adapter refused the job as the necessary legitimization was missing.
0x42D9:The connection was not established because another interface is already active on the TS adapter.
0x42E0:Online: Windows system error in communication driver.
0x42EE:Online: No global memory available.
0x42EF:Online: SIN_SERV not started.
0x42FA:Online: Station is not online.
0x4305:Invalid S7 transport address buffer.
0x4306:Job cannot be found. Wrong wUserID or wrong Windows handle.
0x4430:Cannot read/write data record.
0x4501:Incorrect transfer parameter(s) (for example, incorrect structure Version, Pointer ZERO, etc.).
0x4510:Direct connection with TS Adapter in modem mode.
0x7000:General address error
0x7010:ConTableLen smaller or 0
0x7011:Connection number already assigned parameters
0x7012:Range violation of connection number
0x7015:Connection not loaded
0x7016:Illegal MPI/Profibus/PPI address
0x7017:Illegal MPI address
0x7018:Illegal MPI address
0x7020:No memory available
0x7025:An attribute has the wrong/no value
0x7030:Warning: Active connection number unloaded!!!
0x7040:Buffer too small
0x7041:PDU smaller than data buffer, choose smaller buffer
0x7042:PDU smaller than amount, choose smaller amount
0x7043:Wrong bit number (too small/large)
0x7045:Error when reading data
0x7046:Error when writing data
0x7050:Error when reading DB
0x7051:Error when writing DB
0x7060:Error when reading a block
0x7061:Error when writing a block
0x7062:Too many data are to be read
0x7064:Too many data are to be written
0x7065:No block found
0x7066:Block limit exceeded
0x7070:No filestream, file not found
0x7071:Permitted amount of error messages exceeded
0x7072:Wrong entry in Error.dat
0x7080:Info cannot be read
0x7081:Hardware version and Firmware version cannot be read
0x7082:MLFB cannot be read
0x7085:Status cannot be read
0x7090:A newer Block already exists
0x7100:Block is password-protected, cannot be read
0x8001:(8001) The service requested cannot be performed while the block is in the current state; other block functions are therefore not possible. Repeat the function later.
0x8003:(8003) S7 protocol error: Error occurred while transferring block.
0x8100:(8100) Application, general error: Service unknown to remote module.
0x8104:(8104) This service is not implemented on the module, or a message frame error has been registered.
0x8204:(8204) The type specification for the object is inconsistent.
0x8205:(8205) A copied block already exists and is not linked.
0x8301:(8301) Insufficient memory space or work memory on the module, or specified storage medium not accessible.
0x8302:(8302) Too few resources available or the processor resources are not available.
0x8304:(8304) No further parallel upload possible. Too few resources.
0x8305:(8305) Function not available.
0x8306:(8306) Insufficient work memory (for copying, linking, loading AWP)..
0x8307:(8307) Available work memory not enough (for copying, linking, loading AWP).
0x8401:(8401) S7 protocol error: Invalid service sequence (for example, loading or uploading a block).
0x8402:(8402) Service cannot be performed owing to state of addressed object.
0x8404:(8404) S7 protocol: The function cannot be performed.
0x8405:(8405) Remote block is in DISABLE state (CFB). The function cannot be performed.
0x8500:(8500) S7 protocol error: Wrong message frame.
0x8503:(8503) Message from the module: Service canceled prematurely.
0x8701:(8701) Error addressing the object in the communications partner (for example, area length error).
0x8702:(8702) The requested service is not supported by the module.
0x8703:(8703) Access to object refused.
0x8704:(8704) Access error: Object damaged.
0xD001:(D001) Protocol error: Illegal job number.
⌨️ 快捷键说明