⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 error.dat

📁 西门子Prodave6.0 的Delphi 版本, 需要安装 Prodave60软件,支持以太网通讯
💻 DAT
📖 第 1 页 / 共 2 页
字号:
0x0000:Success
0x0101:Connection not established / no parameters assigned
0x0112:Incorrect parameter
0x0113:Invalid block type.
0x0114:Block not found. 
0x0115:Block already exists. 
0x0116:Block is write-protected. 
0x0117:The block is too large. 
0x0118:Invalid block number. 
0x0119:Incorrect password entered. 
0x011A:PG resource error. 
0x011B:PLC resource error. 
0x011C:Internal error: Protocol error. 
0x011D:Too many blocks (module-related restriction).
0x011E:No connection to database or S7DOS handle invalid.
0x011F:Result buffer too small
0x0120:End of block list. 
0x0140:Insufficient memory available. 
0x0141:Job cannot be processed because resources are missing. 
0x0170:The simulator could not be found. 
0x0180:The activated online function cannot be executed. 
0x0181:Driver already open or too many open channels. 
0x01C1:The field structure of the current database does not match the expected format. 
0x01C3:The length specification in the block header does not match the actual length of a section in the database. 
0x01C4:A problem occurred processing the last ID file. 
0x01C5:Incorrect block format, the block does not have a valid PG format. 
0x01C6:File not found. 
0x01C7:Invalid operating system update components. 
0x01C8:The database given as the destination already exists. 
0x01C9:The database is already blocked by another application. 
0x01CC:A DLL could not be loaded. 
0x01CD:A function could not be found in the dynamically reloaded DLL. 
0x01CF:File not found or access protection violation 
0x01D0:Password not found. 
0x01E0:Diagnostics not activated. 
0x01E1:No diagnostic data are available. 
0x01E2:The diagnostic data are inconsistent.
0x01F0:Function not implemented. 
0x01FF:System error.
0x0312:Wrong configuration parameters
0x0315:MPI address error
0x0805:S7 protocol: Invalid flags. 
0x0810:S7 protocol: The data could not be sent correctly. 
0x0811:S7 protocol: No job found for the received data. 
0x0D80:A diagnostic error occurred. 
0x400A:The communications server could not be started. 
0x400F:The connection to the communications server has been aborted. 
0x401F:No such request in asynchronous list. 
0x4020:No local memory available. 
0x4021:The local memory cannot be locked. 
0x4022:No reply to STEP 7 message frame. 
0x4023:Messages are no longer executed by the CPU. The application does not react. 
0x4060:Wrong Windows mode. 
0x4061:No global memory. 
0x4104:Online: No resources available in the driver. 
0x4107:Online: Connection is closed. 
0x4109:Online: No acknowledgment of the sending and receiving of data. 
0x410E:Online: Connection aborted. 
0x4110:Online: No connection established. No response from remote partner. 
0x4114:Online: Connection already exists. 
0x4116:Online: The connection to the target module cannot be established. 
0x411A:Online: Illegal address. 
0x411C:Online: Network error. 
0x4201:Online: No resources available in the driver. 
0x4211:Online: No other station with master capabilities could be found in the subnet. 
0x4212:Online: Station not online. 
0x4215:Online: Function not implemented or not permitted in current context. 
0x4216:Online: Invalid DP slave station address or error message from DP slave. 
0x4228:The bus parameters could not be automatically determined (online). There are no stations on the bus sending bus parameter message frames. Set the MPI/PROFIBUS interface manually. 
0x4230:Online: No other active partner can be found. 
0x4231:Online: Bus faulty. 
0x4232:Online: Incorrect highest node address. 
0x4233:Online: System error. 
0x42A1:Online: Cannot initialize or open COM interface. 
0x42B0:Online: Hardware not found. 
0x42B1:Online: The local programming device interface is defective. 
0x42B2:Online: Driver configuration error or invalid registry parameter. 
0x42B3:Online: The local MPI address for the programming device/PC is higher than the maximum node address or the wrong transmission rate or wrong interrupt vector is set. 
0x42B5:Online: The set local node address is already in use. 
0x42B6:Online: The configured hardware interface is already being used by another programming package. Close all S7 applications and restart your programming package. 
0x42B7:Online: The set interrupt vector (IRQ) is not available for this module. 
0x42B8:Online: The set interrupt vector (IRQ) is already in use. 
0x42C0:Online: Cannot load the selected communication driver; File not found. 
0x42C1:Online: Function not implemented in loaded communication driver. 
0x42C2:A connection between your PC/programming device and the PLC cannot be established. 
0x42D0:Online: Incompatible adapter version or wrong adapter type connected. 
0x42D1:Online: No interrupt received from PC/MPI cable. 
0x42D2:Online: Communication link to the adapter damaged. 
0x42D3:Online: COM port not configured under Windows. 
0x42D4:Online: COM port currently not accessible. 
0x42D5:Online: The serial driver is currently being used by an application with another configuration. 
0x42D6:Online: The TS adapter interface is set up for a modem connection and there is no remote connection to a TS adapter. 
0x42D7:Online: The TS adapter refused the job as the necessary legitimization was missing. 
0x42D9:The connection was not established because another interface is already active on the TS adapter.
0x42E0:Online: Windows system error in communication driver. 
0x42EE:Online: No global memory available. 
0x42EF:Online: SIN_SERV not started. 
0x42FA:Online: Station is not online. 
0x4305:Invalid S7 transport address buffer. 
0x4306:Job cannot be found. Wrong wUserID or wrong Windows handle. 
0x4430:Cannot read/write data record. 
0x4501:Incorrect transfer parameter(s) (for example, incorrect structure Version, Pointer ZERO, etc.).
0x4510:Direct connection with TS Adapter in modem mode.
0x7000:General address error
0x7010:ConTableLen smaller or 0
0x7011:Connection number already assigned parameters
0x7012:Range violation of connection number
0x7015:Connection not loaded
0x7016:Illegal MPI/Profibus/PPI address
0x7017:Illegal MPI address
0x7018:Illegal MPI address
0x7020:No memory available
0x7025:An attribute has the wrong/no value
0x7030:Warning: Active connection number unloaded!!!
0x7040:Buffer too small
0x7041:PDU smaller than data buffer, choose smaller buffer
0x7042:PDU smaller than amount, choose smaller amount
0x7043:Wrong bit number (too small/large)
0x7045:Error when reading data
0x7046:Error when writing data
0x7050:Error when reading DB
0x7051:Error when writing DB
0x7060:Error when reading a block
0x7061:Error when writing a block
0x7062:Too many data are to be read
0x7064:Too many data are to be written
0x7065:No block found
0x7066:Block limit exceeded
0x7070:No filestream, file not found
0x7071:Permitted amount of error messages exceeded
0x7072:Wrong entry in Error.dat
0x7080:Info cannot be read
0x7081:Hardware version and Firmware version cannot be read
0x7082:MLFB cannot be read
0x7085:Status cannot be read
0x7090:A newer Block already exists
0x7100:Block is password-protected, cannot be read
0x8001:(8001) The service requested cannot be performed while the block is in the current state; other block functions are therefore not possible. Repeat the function later. 
0x8003:(8003) S7 protocol error: Error occurred while transferring block. 
0x8100:(8100) Application, general error: Service unknown to remote module. 
0x8104:(8104) This service is not implemented on the module, or a message frame error has been registered. 
0x8204:(8204) The type specification for the object is inconsistent. 
0x8205:(8205) A copied block already exists and is not linked. 
0x8301:(8301) Insufficient memory space or work memory on the module, or specified storage medium not accessible. 
0x8302:(8302) Too few resources available or the processor resources are not available. 
0x8304:(8304) No further parallel upload possible. Too few resources. 
0x8305:(8305) Function not available. 
0x8306:(8306) Insufficient work memory (for copying, linking, loading AWP)..
0x8307:(8307) Available work memory not enough  (for copying, linking, loading AWP).
0x8401:(8401) S7 protocol error: Invalid service sequence (for example, loading or uploading a block). 
0x8402:(8402) Service cannot be performed owing to state of addressed object. 
0x8404:(8404) S7 protocol: The function cannot be performed. 
0x8405:(8405) Remote block is in DISABLE state (CFB). The function cannot be performed. 
0x8500:(8500) S7 protocol error: Wrong message frame. 
0x8503:(8503) Message from the module: Service canceled prematurely. 
0x8701:(8701) Error addressing the object in the communications partner (for example, area length error). 
0x8702:(8702) The requested service is not supported by the module. 
0x8703:(8703) Access to object refused. 
0x8704:(8704) Access error: Object damaged. 
0xD001:(D001) Protocol error: Illegal job number. 

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =