⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 aic79xx.txt

📁 linux 内核源代码
💻 TXT
📖 第 1 页 / 共 2 页
字号:
     Possible Values: This option is a flag       Default Value: disabled   -----------------------------------------------------------------              Option: reverse_scan          Definition: Probe the scsi bus in reverse order, starting                      with target 15     Possible Values: This option is a flag       Default Value: disabled   -----------------------------------------------------------------              Option: global_tag_depth          Definition: Global tag depth for all targets on all busses.                      This option sets the default tag depth which                      may be selectively overridden vi the tag_info                      option.     Possible Values: 1 - 253       Default Value: 32   -----------------------------------------------------------------              Option: tag_info:{{value[,value...]}[,{value[,value...]}...]}          Definition: Set the per-target tagged queue depth on a                      per controller basis.  Both controllers and targets                      may be ommitted indicating that they should retain                      the default tag depth.            Examples: tag_info:{{16,32,32,64,8,8,,32,32,32,32,32,32,32,32,32}                        On Controller 0                          specifies a tag depth of 16 for target 0                          specifies a tag depth of 64 for target 3                          specifies a tag depth of 8 for targets 4 and 5                          leaves target 6 at the default                          specifies a tag depth of 32 for targets 1,2,7-15                        All other targets retain the default depth.                      tag_info:{{},{32,,32}}                        On Controller 1                          specifies a tag depth of 32 for targets 0 and 2                        All other targets retain the default depth.                             Possible Values: 1 - 253       Default Value: 32   -----------------------------------------------------------------              Option: rd_strm: {rd_strm_bitmask[,rd_strm_bitmask...]}          Definition: Enable read streaming on a per target basis.                      The rd_strm_bitmask is a 16 bit hex value in which                      each bit represents a target.  Setting the target's                      bit to '1' enables read streaming for that                      target.  Controllers may be ommitted indicating that                      they should retain the default read streaming setting.             Example: rd_strm:{0x0041}                        On Controller 0                          enables read streaming for targets 0 and 6.                          disables read streaming for targets 1-5,7-15.                        All other targets retain the default read                        streaming setting.             Example: rd_strm:{0x0023,,0xFFFF}                        On Controller 0                          enables read streaming for targets 1,2, and 5.                          disables read streaming for targets 3,4,6-15.                        On Controller 2                          enables read streaming for all targets.                        All other targets retain the default read                        streaming setting.                           Possible Values: 0x0000 - 0xffff       Default Value: 0x0000   -----------------------------------------------------------------              Option: dv: {value[,value...]}          Definition: Set Domain Validation Policy on a per-controller basis.                      Controllers may be ommitted indicating that                      they should retain the default read streaming setting.             Example: dv:{-1,0,,1,1,0}                        On Controller 0 leave DV at its default setting.                        On Controller 1 disable DV.                        Skip configuration on Controller 2.                        On Controllers 3 and 4 enable DV.                        On Controller 5 disable DV.     Possible Values: < 0 Use setting from serial EEPROM.                      0 Disable DV                      > 0 Enable DV       Default Value: DV Serial EEPROM configuration setting.   -----------------------------------------------------------------              Option: seltime:[value]          Definition: Specifies the selection timeout value     Possible Values: 0 = 256ms, 1 = 128ms, 2 = 64ms, 3 = 32ms       Default Value: 0   -----------------------------------------------------------------   *** The following three options should only be changed at ***   *** the direction of a technical support representative.  ***   -----------------------------------------------------------------              Option: precomp: {value[,value...]}          Definition: Set IO Cell precompensation value on a per-controller                      basis.                      Controllers may be ommitted indicating that                      they should retain the default precompensation setting.             Example: precomp:{0x1}                        On Controller 0 set precompensation to 1.             Example: precomp:{1,,7}                        On Controller 0 set precompensation to 1.                        On Controller 2 set precompensation to 8.                           Possible Values: 0 - 7       Default Value: Varies based on chip revision   -----------------------------------------------------------------              Option: slewrate: {value[,value...]}          Definition: Set IO Cell slew rate on a per-controller basis.                      Controllers may be ommitted indicating that                      they should retain the default slew rate setting.             Example: slewrate:{0x1}                        On Controller 0 set slew rate to 1.             Example: slewrate :{1,,8}                        On Controller 0 set slew rate to 1.                        On Controller 2 set slew rate to 8.                           Possible Values: 0 - 15       Default Value: Varies based on chip revision   -----------------------------------------------------------------              Option: amplitude: {value[,value...]}          Definition: Set IO Cell signal amplitude on a per-controller basis.                      Controllers may be ommitted indicating that                      they should retain the default read streaming setting.             Example: amplitude:{0x1}                        On Controller 0 set amplitude to 1.             Example: amplitude :{1,,7}                        On Controller 0 set amplitude to 1.                        On Controller 2 set amplitude to 7.                           Possible Values: 1 - 7       Default Value: Varies based on chip revision   -----------------------------------------------------------------   Example: 'options aic79xx aic79xx=verbose,rd_strm:{{0x0041}}'        enables verbose output in the driver and turns read streaming on        for targets 0 and 6 of Controller 0.4. Additional Notes   4.1. Known/Unresolved or FYI Issues        * Under SuSE Linux Enterprise 7, the driver may fail to operate          correctly due to a problem with PCI interrupt routing in the          Linux kernel.  Please contact SuSE for an updated Linux          kernel.   4.2. Third-Party Compatibility Issues        * Adaptec only supports Ultra320 hard drives running          the latest firmware available. Please check with          your hard drive manufacturer to ensure you have the          latest version.   4.3. Operating System or Technology Limitations                * PCI Hot Plug is untested and may cause the operating system           to stop responding.        * Luns that are not numbered contiguously starting with 0 might not          be automatically probed during system startup.  This is a limitation          of the OS.  Please contact your Linux vendor for instructions on          manually probing non-contiguous luns.        * Using the Driver Update Disk version of this package during OS          installation under RedHat might result in two versions of this          driver being installed into the system module directory.  This          might cause problems with the /sbin/mkinitrd program and/or          other RPM packages that try to install system modules.  The best          way to correct this once the system is running is to install          the latest RPM package version of this driver, available from          http://www.adaptec.com.5. Adaptec Customer Support   A Technical Support Identification (TSID) Number is required for    Adaptec technical support.    - The 12-digit TSID can be found on the white barcode-type label      included inside the box with your product.  The TSID helps us       provide more efficient service by accurately identifying your       product and support status.   Support Options    - Search the Adaptec Support Knowledgebase (ASK) at      http://ask.adaptec.com for articles, troubleshooting tips, and      frequently asked questions about your product.    - For support via Email, submit your question to Adaptec's       Technical Support Specialists at http://ask.adaptec.com/.        North America    - Visit our Web site at http://www.adaptec.com/.    - For information about Adaptec's support options, call      408-957-2550, 24 hours a day, 7 days a week.    - To speak with a Technical Support Specialist,      * For hardware products, call 408-934-7274,        Monday to Friday, 3:00 am to 5:00 pm, PDT.      * For RAID and Fibre Channel products, call 321-207-2000,        Monday to Friday, 3:00 am to 5:00 pm, PDT.      To expedite your service, have your computer with you.    - To order Adaptec products, including accessories and cables,      call 408-957-7274.  To order cables online go to      http://www.adaptec.com/buy-cables/.   Europe    - Visit our Web site at http://www.adaptec-europe.com/.    - To speak with a Technical Support Specialist, call, or email,      * German:  +49 89 4366 5522, Monday-Friday, 9:00-17:00 CET,        http://ask-de.adaptec.com/.      * French:  +49 89 4366 5533, Monday-Friday, 9:00-17:00 CET,	http://ask-fr.adaptec.com/.      * English: +49 89 4366 5544, Monday-Friday, 9:00-17:00 GMT,	http://ask.adaptec.com/.    - You can order Adaptec cables online at      http://www.adaptec.com/buy-cables/.   Japan    - Visit our web site at http://www.adaptec.co.jp/.    - To speak with a Technical Support Specialist, call       +81 3 5308 6120, Monday-Friday, 9:00 a.m. to 12:00 p.m.,      1:00 p.m. to 6:00 p.m.-------------------------------------------------------------------/* * Copyright (c) 2003 Adaptec Inc. 691 S. Milpitas Blvd., Milpitas CA 95035 USA. * All rights reserved. * * You are permitted to redistribute, use and modify this README file in whole * or in part in conjunction with redistribution of software governed by the * General Public License, provided that the following conditions are met: * 1. Redistributions of README file must retain the above copyright *    notice, this list of conditions, and the following disclaimer, *    without modification. * 2. The name of the author may not be used to endorse or promote products *    derived from this software without specific prior written permission. * 3. Modifications or new contributions must be attributed in a copyright *    notice identifying the author ("Contributor") and added below the *    original copyright notice. The copyright notice is for purposes of *    identifying contributors and should not be deemed as permission to alter *    the permissions given by Adaptec. * * THIS README FILE IS PROVIDED BY ADAPTEC AND CONTRIBUTORS ``AS IS'' AND * ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, ANY * WARRANTIES OF NON-INFRINGEMENT OR THE IMPLIED WARRANTIES OF MERCHANTABILITY * AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL * ADAPTEC OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, * SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED * TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR * PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF * LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING * NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS README * FILE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. */

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -