⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 vt1211

📁 linux 内核源代码
💻
字号:
Kernel driver vt1211====================Supported chips:  * VIA VT1211    Prefix: 'vt1211'    Addresses scanned: none, address read from Super-I/O config space    Datasheet: Provided by VIA upon request and under NDAAuthors: Juerg Haefliger <juergh@gmail.com>This driver is based on the driver for kernel 2.4 by Mark D. Studebaker andits port to kernel 2.6 by Lars Ekman.Thanks to Joseph Chan and Fiona Gatt from VIA for providing documentation andtechnical support.Module Parameters-----------------* uch_config: int	Override the BIOS default universal channel (UCH)			configuration for channels 1-5.			Legal values are in the range of 0-31. Bit 0 maps to			UCH1, bit 1 maps to UCH2 and so on. Setting a bit to 1			enables the thermal input of that particular UCH and			setting a bit to 0 enables the voltage input.* int_mode: int		Override the BIOS default temperature interrupt mode.			The only possible value is 0 which forces interrupt			mode 0. In this mode, any pending interrupt is cleared			when the status register is read but is regenerated as			long as the temperature stays above the hysteresis			limit.Be aware that overriding BIOS defaults might cause some unwanted side effects!Description-----------The VIA VT1211 Super-I/O chip includes complete hardware monitoringcapabilities. It monitors 2 dedicated temperature sensor inputs (temp1 andtemp2), 1 dedicated voltage (in5) and 2 fans. Additionally, the chipimplements 5 universal input channels (UCH1-5) that can be individuallyprogrammed to either monitor a voltage or a temperature.This chip also provides manual and automatic control of fan speeds (accordingto the datasheet). The driver only supports automatic control since the manualmode doesn't seem to work as advertised in the datasheet. In fact I couldn'tget manual mode to work at all! Be aware that automatic mode hasn't beentested very well (due to the fact that my EPIA M10000 doesn't have the fansconnected to the PWM outputs of the VT1211 :-().The following table shows the relationship between the vt1211 inputs and thesysfs nodes.Sensor          Voltage Mode   Temp Mode   Default Use (from the datasheet)------          ------------   ---------   --------------------------------Reading 1                      temp1       Intel thermal diodeReading 3                      temp2       Internal thermal diodeUCH1/Reading2   in0            temp3       NTC type thermistorUCH2            in1            temp4       +2.5VUCH3            in2            temp5       VccP (processor core)UCH4            in3            temp6       +5VUCH5            in4            temp7       +12V+3.3V           in5                        Internal VCC (+3.3V)Voltage Monitoring------------------Voltages are sampled by an 8-bit ADC with a LSB of ~10mV. The supported inputrange is thus from 0 to 2.60V. Voltage values outside of this range needexternal scaling resistors. This external scaling needs to be compensated forvia compute lines in sensors.conf, like:compute inx @*(1+R1/R2), @/(1+R1/R2)The board level scaling resistors according to VIA's recommendation are asfollows. And this is of course totally dependent on the actual boardimplementation :-) You will have to find documentation for your ownmotherboard and edit sensors.conf accordingly.                                      ExpectedVoltage       R1     R2     Divider   Raw Value-----------------------------------------------+2.5V         2K     10K    1.2       2083 mVVccP          ---    ---    1.0       1400 mV (1)+5V           14K    10K    2.4       2083 mV+12V          47K    10K    5.7       2105 mV+3.3V (int)   2K     3.4K   1.588     3300 mV (2)+3.3V (ext)   6.8K   10K    1.68      1964 mV(1) Depending on the CPU (1.4V is for a VIA C3 Nehemiah).(2) R1 and R2 for 3.3V (int) are internal to the VT1211 chip and the driver    performs the scaling and returns the properly scaled voltage value.Each measured voltage has an associated low and high limit which triggers analarm when crossed.Temperature Monitoring----------------------Temperatures are reported in millidegree Celsius. Each measured temperaturehas a high limit which triggers an alarm if crossed. There is an associatedhysteresis value with each temperature below which the temperature has to dropbefore the alarm is cleared (this is only true for interrupt mode 0). Theinterrupt mode can be forced to 0 in case the BIOS doesn't do itautomatically. See the 'Module Parameters' section for details.All temperature channels except temp2 are external. Temp2 is the VT1211internal thermal diode and the driver does all the scaling for temp2 andreturns the temperature in millidegree Celsius. For the external channelstemp1 and temp3-temp7, scaling depends on the board implementation and needsto be performed in userspace via sensors.conf.Temp1 is an Intel-type thermal diode which requires the following formula toconvert between sysfs readings and real temperatures:compute temp1 (@-Offset)/Gain, (@*Gain)+OffsetAccording to the VIA VT1211 BIOS porting guide, the following gain and offsetvalues should be used:Diode Type      Offset   Gain----------      ------   ----Intel CPU       88.638   0.9528                65.000   0.9686   *)VIA C3 Ezra     83.869   0.9528VIA C3 Ezra-T   73.869   0.9528*) This is the formula from the lm_sensors 2.10.0 sensors.conf file. I don'tknow where it comes from or how it was derived, it's just listed here forcompleteness.Temp3-temp7 support NTC thermistors. For these channels, the driver returnsthe voltages as seen at the individual pins of UCH1-UCH5. The voltage at thepin (Vpin) is formed by a voltage divider made of the thermistor (Rth) and ascaling resistor (Rs):Vpin = 2200 * Rth / (Rs + Rth)   (2200 is the ADC max limit of 2200 mV)The equation for the thermistor is as follows (google it if you want to knowmore about it):Rth = Ro * exp(B * (1 / T - 1 / To))   (To is 298.15K (25C) and Ro is the                                        nominal resistance at 25C)Mingling the above two equations and assuming Rs = Ro and B = 3435 yields thefollowing formula for sensors.conf:compute tempx 1 / (1 / 298.15 - (` (2200 / @ - 1)) / 3435) - 273.15,              2200 / (1 + (^ (3435 / 298.15 - 3435 / (273.15 + @))))Fan Speed Control-----------------The VT1211 provides 2 programmable PWM outputs to control the speeds of 2fans. Writing a 2 to any of the two pwm[1-2]_enable sysfs nodes will put thePWM controller in automatic mode. There is only a single controller thatcontrols both PWM outputs but each PWM output can be individually enabled anddisabled.Each PWM has 4 associated distinct output duty-cycles: full, high, low andoff. Full and off are internally hard-wired to 255 (100%) and 0 (0%),respectively. High and low can be programmed viapwm[1-2]_auto_point[2-3]_pwm. Each PWM output can be associated with adifferent thermal input but - and here's the weird part - only one set ofthermal thresholds exist that controls both PWMs output duty-cycles. Thethermal thresholds are accessible via pwm[1-2]_auto_point[1-4]_temp. Notethat even though there are 2 sets of 4 auto points each, they map to the sameregisters in the VT1211 and programming one set is sufficient (actually onlythe first set pwm1_auto_point[1-4]_temp is writable, the second set isread-only).PWM Auto Point             PWM Output Duty-Cycle------------------------------------------------pwm[1-2]_auto_point4_pwm   full speed duty-cycle (hard-wired to 255)pwm[1-2]_auto_point3_pwm   high speed duty-cyclepwm[1-2]_auto_point2_pwm   low speed duty-cyclepwm[1-2]_auto_point1_pwm   off duty-cycle (hard-wired to 0)Temp Auto Point             Thermal Threshold---------------------------------------------pwm[1-2]_auto_point4_temp   full speed temppwm[1-2]_auto_point3_temp   high speed temppwm[1-2]_auto_point2_temp   low speed temppwm[1-2]_auto_point1_temp   off tempLong story short, the controller implements the following algorithm to set thePWM output duty-cycle based on the input temperature:Thermal Threshold             Output Duty-Cycle                    (Rising Temp)           (Falling Temp)----------------------------------------------------------                    full speed duty-cycle   full speed duty-cyclefull speed temp                    high speed duty-cycle   full speed duty-cyclehigh speed temp                    low speed duty-cycle    high speed duty-cyclelow speed temp                    off duty-cycle          low speed duty-cycleoff temp

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -