📄 standard-mib.mib
字号:
STANDARD-MIB DEFINITIONS ::= BEGIN IMPORTS Counter, TimeTicks, IpAddress FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 mgmt, NetworkAddress, IpAddress, Counter, Gauge, TimeTicks FROM RFC1155-SMI DisplayString, mib-2 FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212; -- Standard Datatypes -- Represents a boolean value (from rfc1443) TruthValue ::= INTEGER { true(1), false(2) } -- From SNMPv2 (rfc1443) RowStatus ::= INTEGER { -- the following two values are states: -- these values may be read or written active(1), notInService(2), -- the following value is a state: -- this value may be read, but not written notReady(3), -- the following three values are -- actions: these values may be written, -- but are never read createAndGo(4), createAndWait(5), destroy(6) } system OBJECT IDENTIFIER ::= { mib-2 1 } snmp OBJECT IDENTIFIER ::= { mib-2 11 } -- the System group -- Implementation of the System group is mandatory for all -- systems. If an agent is not configured to have a value -- for any of these variables, a string of length 0 is -- returned. sysDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. It is mandatory that this only contain printable ASCII characters." ::= { system 1 } sysObjectID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining `what kind of box' is being managed. For example, if vendor `Flintstones, Inc.' was assigned the subtree 1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'." ::= { system 2 } sysUpTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The time (in hundredths of a second) since the network management portion of the system was last re-initialized." ::= { system 3 } sysContact OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "The textual identification of the contact person for this managed node, together with information on how to contact this person." ::= { system 4 } sysName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name." ::= { system 5 } sysLocation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "The physical location of this node (e.g., `telephone closet, 3rd floor')." ::= { system 6 } sysServices OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "A value which indicates the set of services that this entity primarily offers. The value is a sum. This sum initially takes the value zero, Then, for each layer, L, in the range 1 through 7, that this node performs transactions for, 2 raised to (L - 1) is added to the sum. For example, a node which performs primarily routing functions would have a value of 4 (2^(3-1)). In contrast, a node which is a host offering application services would have a value of 72 (2^(4-1) + 2^(7-1)). Note that in the context of the Internet suite of protocols, values should be calculated accordingly: layer functionality 1 physical (e.g., repeaters) 2 datalink/subnetwork (e.g., bridges) 3 internet (e.g., IP gateways) 4 end-to-end (e.g., IP hosts) 7 applications (e.g., mail relays) For systems including OSI protocols, layers 5 and 6 may also be counted." ::= { system 7 } -- the SNMP group -- Implementation of the SNMP group is mandatory for all -- systems which support an SNMP protocol entity. Some of -- the objects defined below will be zero-valued in those -- SNMP implementations that are optimized to support only -- those functions specific to either a management agent or -- a management station. In particular, it should be -- observed that the objects below refer to an SNMP entity, -- and there may be several SNMP entities residing on a -- managed node (e.g., if the node is hosting acting as -- a management station). snmpInPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of Messages delivered to the SNMP entity from the transport service." ::= { snmp 1 } snmpOutPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP Messages which were passed from the SNMP protocol entity to the transport service." ::= { snmp 2 } snmpInBadVersions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP Messages which were delivered to the SNMP protocol entity and were for an unsupported SNMP version." ::= { snmp 3 } snmpInBadCommunityNames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP Messages delivered to the SNMP protocol entity which used a SNMP community name not known to said entity." ::= { snmp 4 } snmpInBadCommunityUses OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP Messages delivered to the SNMP protocol entity which represented an SNMP operation which was not allowed by the SNMP community named in the Message." ::= { snmp 5 } snmpInASNParseErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of ASN.1 or BER errors encountered by the SNMP protocol entity when decoding received SNMP Messages." ::= { snmp 6 } -- { snmp 7 } is not used snmpInTooBigs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP PDUs which were delivered to the SNMP protocol entity and for which the value of the error-status field is `tooBig'." ::= { snmp 8 } snmpInNoSuchNames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP PDUs which were
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -