⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 sxy.prg

📁 matlab编写的电压稳定分析程序
💻 PRG
📖 第 1 页 / 共 5 页
字号:





           *********************************************************
           *                                                       *
           *                                                       *
           *           Voltage Security Assessment Tool            *
           *                       (V S A T)                       *
           *                                                       *
           *         Security / Transfer Limit Computation         *
           *                                                       *
           *           Version 5.1     Release 15/05/05            *
           *                                                       *
           *              Developed and maintained by              *
           *                  Powertech Labs Inc.                  *
           *                  12388 - 88TH Avenue                  *
           *               Surrey, British Columbia                *
           *                    Canada  V3W 7R7                    *
           *                                                       *
           *                  Copyright  BC Hydro                  *
           *                  All rights reserved                  *
           *                                                       *
           *********************************************************


                        RUN TIME:  07-JUN-05  11:02:20
1

 Data file names read from the Scenario file:  t-xy.snr


   Scenario description:
         BCH 1400-bus case:  East vs North transfer
   End of description

          PFB file=                       "tc1.pfb"
          Parameter file=                 "t.prm"
          Transfer file=                  "t-xy.trf"
          Criteria file=                  "t.crt"
          Monitored Variable file=        "t.mon"
          Margin file=                    "t.mrg"
          Contingency file=               "t-xy.ctg"
          Interface and Circuit file=     "t.itf"

 PFB (base power flow) file:  tc1.pfb                                                                                                                             


   Base powerflow case:

     Test Case A                                                                     
                                                                                     
                                                                                     
     Created/modified on:  28-APR-05         13:16:20

     Buses                         1397
     Areas                            5
     Zones                           35
     Generating units               233
     Loads                          604
     Fixed shunts                   390
     Switched shunts / SVCs         150
     Lines                         1512
     Fixed transformers             398
     Adjustable transformers        383
     Three winding transformers       0
     Fixed series compensators        0
     Adjustable series comp.          0
     Static tap-ch./phase-reg.        0
     DC records                      14

1

 Parameter file:  t.prm                                                                                                                               


   Transfer analysis =                               To Limit
   Contingency analysis =                   To first insecure
   Generation dispatch for contingencies =               None
   VQ curve interval =                                      0
   Modal Analysis =                                         F
   Convert load models =                                    F
   Use generator capability curves =                        F

   Check branch flows =                                     F
   Line rating no. =                                        0
   Transformer rating no. =                                 0
   Post-contingency line rating no. =                       0
   Post-contingency transformer rating no. =                0
   Threshold for flow check =                             0.0 %
   Threshold for post-contingency flow check =            0.0 %
   Exclude branches below kV level =                     -1.0

   Limit generator VArs =                              Always             
   Remote control by generators =                      Always             
   Adjust ULTCS for voltage control =                  In Pre-Contingency 
   Adjust ULTCS for MVAr flow control =                 Never             
   Adjust phase-shifters for MW flow control =          Never             
   Adjust static tap-changers for voltage control =     Never             
   Adjust static tap-changers for MVar control =        Never             
   Adjust static phase-shifters for MW control =        Never             
   Adjust static series compensators =                  Never             
   Adjust SVC / continuous switched shunts =           Always             
   Adjust discrete switched shunts =                    Never             
   Adjust area interchanges =                           Never             

   Maximum iterations for PF solution =                    90
   Convergence tolerance for PF solution =               1.00 MW
   Acceleration for PV bus voltage =                     0.90
   Tolerance for PV bus voltage =                     0.10E-3
   Blow up voltage =                                    1.000
   Maximum iterations for adjustments =                    70
   Adjustments threshold =                             0.0100
   Low impedance threshold =                          0.10E-3
   Shunt voltage band threshold =                     0.10E-1
   FDPF solution method =                                   1

   Report bus information =                                 F
   Report generator information =                           F
   Report VAr-limited generator information =               F
   Report interface flows =                                 F
   Report circuit flows =                                   F
   Report branch flows =                                    F
   Report adjusted transformers for voltage control =       F
   Report transformers for flow control =                   F
   Report static tap-changers/phase-shifters =              F
   Report series compensators =                             F
   Report adjusted switchable shunts =                      F
   Report area interchange information =                    F
   Report AGC information =                                 F
   Report DC network solutions =                         None

   Name option =                                           No
   Flat start =                                             F
   Show ULTC adjustments during PF solution =               T
   Voltage correction tolerance for base case =        0.9000
   Output volume =                                          0


1

 Interface file:  t.itf                                                                                                                               



                                            Interfaces

   --------------------------------------------------------------------------------------
   Interface name     No. < From bus > Name           No. < To bus > Name      Circuit id
   --------------------------------------------------------------------------------------
      NORT-CEN
                      4511   B4511 500.               5512   B5512 500.              1       
                      4511   B4511 500.               5512   B5512 500.              2       
                      4511   B4511 500.               5512   B5512 500.              3       
      EAST-CEN
                      5501   B5501 500.               5511   B5511 500.              1       
                      5501   B5501 500.               5511   B5511 500.              2       
                      5510   B5510 500.               5511   B5511 500.              1       
                      5510   B5510 500.               5511   B5511 500.              2       


                                             Circuits
   --------------------------------------------------------------------------------------
    Circuit name      No. < From bus > Name           No. < To bus > Name      Circuit id
   --------------------------------------------------------------------------------------
     5L41    
                      1544   B1544 500.               5512   B5512 500.              1       
1

 Transfer file:  t-xy.trf                                                                                                                            


   Transfer description:
         Secure rigion: East-vs-North gen, with Area1 load
   End of description


   Transfer name=        E vs N      

   Step size=                 100.000 MW

   Source X:
     Source name=          EAST GEN    
     Decrease limit=           500.00 MW
     Increase limit=           800.00 MW

     Set  1 - Generation Scale group  1:
       Group share=            100.00
       Include zone=    5  
       Include zone=    6  

 #Notice#    8  swing, negative or out of service generations in this group will not be scaled


   Source D:
     Source name=          LM LOAD     
     Decrease limit=          9999.00 MW
     Increase limit=          9999.00 MW

     Set  2 - Load Scale group  1:
       Group share=            100.00
       Scale load=            P and Q
       Include area=    1

 #Notice#     1  Negative loads in this group will remain constant


   Source Y:
     Source name=          NORT GEN    
     Decrease limit=           500.00 MW
     Increase limit=           700.00 MW

     Set  3 - Generation Scale group  2:
       Group share=            100.00
       Include zone=    4  

 #Notice#    2  swing, negative or out of service generations in this group will not be scaled


   Source D:

     Set       Group       %Share   No <Load/Gen> MW    Max <  MW  > Min
     ---   -------------   ------   ----------------    ----------------
       2   Load-Scale  1   100.0     290     7665.75

     Original load-gen.:     7665.75 MW
     Minimum value:             5.00 MW
     Maximum value:         17664.75 MW
     Minimum value is limited by set   2

   Source Y:

     Set       Group       %Share   No <Load/Gen> MW    Max <  MW  > Min
     ---   -------------   ------   ----------------    ----------------
       3   Gen.-Scale  2   100.0      15     2849.98     3547.0     0.00

     Original gen.-load:     2849.98 MW
     Minimum value:          2349.98 MW
     Maximum value:          3547.00 MW
     Maximum value is limited by set   3


   Source X:

     Set       Group       %Share   No <Load/Gen> MW    Max <  MW  > Min
     ---   -------------   ------   ----------------    ----------------
       1   Gen.-Scale  1   100.0      22     3500.00     4215.0     0.00

     Original gen.-load:     3500.00 MW
     Minimum value:          3000.00 MW
     Maximum value:          4215.00 MW
     Maximum value is limited by set   1
1

 Criteria file:  t.crt                                                                                                                               


   Criteria description:
        7% voltage decline in area 1
        12% Q reserve in each of zones 1, 4, 5, 6
        10% Q reserve in zone 30
        15 MVAr reserve in SVC
   End of description


   Criteria name=  Criteria    

   Voltage criteria group   1:
     Decline limit =       0.07000
     Rise limit =          0.99000
       Include area=     1
     Number of buses:       860

   VAr reserve criteria group   1:
     Reserve limit =               12.00 %
     Include generators of zone =     1

     Number of gen. units:     10
     Number of shunt units:     0

   VAr reserve criteria group   2:
     Reserve limit =               12.00 %
     Include generators of zone =     4

     Number of gen. units:     17
     Number of shunt units:     0

   VAr reserve criteria group   3:
     Reserve limit =               12.00 %
     Include generators of zone =     5

     Number of gen. units:     15
     Number of shunt units:     0

   VAr reserve criteria group   4:
     Reserve limit =               12.00 %
     Include generators of zone =     6

     Number of gen. units:     15
     Number of shunt units:     0

   VAr reserve criteria group   5:
     Reserve limit =               10.00 %
     Include generators of zone =     30

     Number of gen. units:      9
     Number of shunt units:     0

   VAr reserve criteria group   6:
     Reserve limit =               15.00 MVAr
     Include variable shunts of bus =     2816

     Number of gen. units:      0
     Number of shunt units:     1
1

 Monitored Variable file:  t.mon                                                                                                                               


   Monitor description:
         Monitor bus voltages, interface flows,
         and Criteria reactive reserves
   End of description


   Monitor name=  TestMon     
   Voltage of bus=              7799
   Voltage of bus=              5512, 5511,  501
   Voltage of bus=              7798, 6207
   Voltage of bus=               201,  203, 1201, 101
   MW flow of interface=     NORT-CEN
   MW flow of interface=     EAST-CEN
   MVAr flow of interface=   NORT-CEN
   MVAr flow of interface=   EAST-CEN
   Criteria MVAr reserves=      Yes         

   Number of monitored bus voltages    =       10
   Number of monitored interface flows =        4
   Number of monitored circuit flows   =        0
   Number of monitored bus  Q reserves =        0
   Number of monitored zone Q reserves =        0



 Margin file:  t.mrg                                                                                                                               


   Margin description:
         200 MW load/gen increase in area 1
   End of description


   Margin name=  200MW LD    

   Load scale group   1:
       Scale load=            P and Q
       Increase by=            200.00 MW/MVAr
       Include area=     1
     Number of loads:             291
     Initial MW load:         7217.39
     Initial MVAR load:       3525.26

   Generation scale group   2:
       Increase by=            200.00 MW
       Include area=     1
     Number of generators:        101
     Initial MW generation:   7569.11



 Contingency file:  t-xy.ctg                                                                                                                            

     9 Contingencies:
                       CC41        CC42        CC81        CC82        CC87    
                       A   4       A   8       A  19       A  20   

   Number of low-impedance lines  (Z< 0.00010) :    5
   Number of increased reactances (X= 0.00010) :    0
   Reduced number of buses :                     1311

   Ordering the matrix
1

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -