>> Removing pre-contingency stability margin violation
>> Controls succeeded in removing pre-contingency stability margin violation
>> Removing pre-contingency VAr reserve violations
>> Preventive control is completed for pre-contingency case only
All pre-contingency violations are removed
>> Corrective control for post-contingency stability
>> Correcting contingency CC41
>> Control succeeded in solving contingency before stress
>> Correcting voltage violations
>> Controls succeeded in removing voltage violations
>> Correcting stability margin violation
>> Control succeeded in removing stability margin violation
>> Correcting VAr reserve violations
>> Corrective control is completed for this contingency
All violations of this contingency are removed
>> Correcting contingency CC42
>> Control succeeded in solving contingency before stress
>> Correcting voltage violations
>> Controls succeeded in removing voltage violations
>> Correcting stability margin violation
>> Load shedding
Group # delt-P(MW) Sensit.
1 -259.4545 0.486
>> Load shedding was effective in increasing the stability margin
>> Control succeeded in removing stability margin violation
>> Correcting VAr reserve violations
>> Corrective control is completed for this contingency
All violations of this contingency are removed
>> Correcting contingency CC81
>> Control succeeded in solving contingency before stress
>> Correcting voltage violations
>> Controls succeeded in removing voltage violations
>> Correcting stability margin violation
>> Load shedding
Group # delt-P(MW) Sensit.
1 -259.4545 0.445
>> Load shedding was effective in increasing the stability margin
>> Control succeeded in removing stability margin violation
>> Correcting VAr reserve violations
>> Corrective control is completed for this contingency
All violations of this contingency are removed
>> Correcting contingency CC82
>> Control succeeded in solving contingency before stress
>> Correcting voltage violations
>> Controls succeeded in removing voltage violations
>> Correcting stability margin violation
>> Load shedding
Group # delt-P(MW) Sensit.
1 -259.4545 0.461
>> Load shedding was effective in increasing the stability margin
>> Control succeeded in removing stability margin violation
>> Correcting VAr reserve violations
>> Corrective control is completed for this contingency
All violations of this contingency are removed
>> Correcting contingency CC87
>> Control succeeded in solving contingency before stress
>> Correcting voltage violations
>> Controls succeeded in removing voltage violations
>> Correcting stability margin violation
>> Control succeeded in removing stability margin violation
>> Correcting VAr reserve violations
>> Corrective control is completed for this contingency
All violations of this contingency are removed
>> Correcting contingency A 4
>> Control succeeded in solving contingency before stress
>> Correcting voltage violations
>> Controls succeeded in removing voltage violations
>> Correcting stability margin violation
>> Load shedding
Group # delt-P(MW) Sensit.
1 -259.4545 0.486
>> Load shedding was effective in increasing the stability margin
>> Control succeeded in removing stability margin violation
>> Correcting VAr reserve violations
>> Corrective control is completed for this contingency
All violations of this contingency are removed
>> Correcting contingency A 8
>> Control succeeded in solving contingency before stress
>> Correcting voltage violations
>> Controls succeeded in removing voltage violations
>> Correcting stability margin violation
>> Load shedding
Group # delt-P(MW) Sensit.
1 -259.4545 0.461
>> Load shedding was effective in increasing the stability margin
>> Control succeeded in removing stability margin violation
>> Correcting VAr reserve violations
>> Corrective control is completed for this contingency
All violations of this contingency are removed