📄 frequency_counter.ucf
字号:
# Constraints for reference design 'frequency_counter'.
#
# Revision C of the Spartan-3E Starter Kit.
#
# Ken Chapman - Xilinx Ltd - 24th February 2006
#
# Period constraint for 50MHz operation
#
NET "clk_50mhz" PERIOD = 20.0ns HIGH 50%;
#
# Period constraint for up to 200MHz operation
#
NET "test_clk" PERIOD = 5.0ns HIGH 50%;
#
#
# soldered 50MHz Clock.
#
NET "clk_50mhz" LOC = "C9" | IOSTANDARD = LVTTL;
#
# SMA socket.
#
NET "sma_clk" LOC = "A10" | IOSTANDARD = LVTTL;
#
#
# Simple LEDs
# Require only 3.5mA.
#
NET "led<0>" LOC = "F12" | IOSTANDARD = LVTTL | SLEW = SLOW | DRIVE = 4;
NET "led<1>" LOC = "E12" | IOSTANDARD = LVTTL | SLEW = SLOW | DRIVE = 4;
NET "led<2>" LOC = "E11" | IOSTANDARD = LVTTL | SLEW = SLOW | DRIVE = 4;
NET "led<3>" LOC = "F11" | IOSTANDARD = LVTTL | SLEW = SLOW | DRIVE = 4;
NET "led<4>" LOC = "C11" | IOSTANDARD = LVTTL | SLEW = SLOW | DRIVE = 4;
NET "led<5>" LOC = "D11" | IOSTANDARD = LVTTL | SLEW = SLOW | DRIVE = 4;
NET "led<6>" LOC = "E9" | IOSTANDARD = LVTTL | SLEW = SLOW | DRIVE = 4;
NET "led<7>" LOC = "F9" | IOSTANDARD = LVTTL | SLEW = SLOW | DRIVE = 4;
#
#
# LCD display
# Very slow so can use lowest drive strength.
#
NET "lcd_rs" LOC = "L18" | IOSTANDARD = LVTTL | SLEW = SLOW | DRIVE = 2;
NET "lcd_rw" LOC = "L17" | IOSTANDARD = LVTTL | SLEW = SLOW | DRIVE = 2;
NET "lcd_e" LOC = "M18" | IOSTANDARD = LVTTL | SLEW = SLOW | DRIVE = 2;
NET "lcd_d<4>" LOC = "R15" | IOSTANDARD = LVTTL | SLEW = SLOW | DRIVE = 2;
NET "lcd_d<5>" LOC = "R16" | IOSTANDARD = LVTTL | SLEW = SLOW | DRIVE = 2;
NET "lcd_d<6>" LOC = "P17" | IOSTANDARD = LVTTL | SLEW = SLOW | DRIVE = 2;
NET "lcd_d<7>" LOC = "M15" | IOSTANDARD = LVTTL | SLEW = SLOW | DRIVE = 2;
#
# Strata Flash (need to disable to use LCD display)
#
NET "strataflash_oe" LOC = "C18" | IOSTANDARD = LVTTL | SLEW = SLOW | DRIVE = 2;
NET "strataflash_ce" LOC = "D16" | IOSTANDARD = LVTTL | SLEW = SLOW | DRIVE = 2;
NET "strataflash_we" LOC = "D17" | IOSTANDARD = LVTTL | SLEW = SLOW | DRIVE = 2;
#
#
# Simple switches
# Pull UP resistors used to stop floating condition during switching.
#
NET "sw<0>" LOC = "L13" | IOSTANDARD = LVTTL | PULLUP;
NET "sw<1>" LOC = "L14" | IOSTANDARD = LVTTL | PULLUP;
NET "sw<2>" LOC = "H18" | IOSTANDARD = LVTTL | PULLUP;
NET "sw<3>" LOC = "N17" | IOSTANDARD = LVTTL | PULLUP;
#
#
#
# End of File
#