Full Text Bug Listing  
    
 
Bug 35588 - The Capacities of STRATAFLASH are always changed after format it. 
Bug#: 35588  Product: Scorpius  Version: 1.0.001  Platform: EP931X  
OS/Version: Other  Status: NEW  Severity: Major  Priority: P2  
Bug_Type: Test  Originator: Test  Version_Tested: 1.0.001  Win_CE_Version: CE .net 4.0  CE_Test_Kit_Version:   CE_Test_Name:   CE_Test_Kit_Failure_Test_Number_Field:   Nexus_Board_Number: ED150057  Nexus_Board_Type: EDB9315A  
Resolution:   Assigned To: xin.xing@cirrus.com  Reported By: ping.jing@cirrus.com  QA Contact:   
Component: Flash File System:  Target Milestone: 1.0.100  
URL:   
Summary: The Capacities of STRATAFLASH are always changed after format it.  
Description:  

Board: EDB9315 ED150057
Chip:  EP9312 - CB EFWAE1AB0515
Version: scorpius 1-0-001
How frequently: Always

Steps:
1, boot up system by using the eboot and nk.bin shipped with project.
2, open <storage manager>
3, Choose MSFlash MSFlash for STRATAFLASH.
4, check the capacity, in my case: 3.20MB
5, click button <Dismount> to dismount it.
6, click button <Format> to format it.
7, click button <New> to create a patition.
8, check the capacity again: in my case: 2.41MB
9, repeat step3 -- 8.

result: the capacities of STRATAFLASH are always changed.

------- Additional Comment #1 From Javier Montalvo 2005-07-20 10:21 ------- 
setting target milestone to 1.0.002

------- Additional Comment #2 From Javier Montalvo 2005-07-20 10:59 ------- 
setting to 1.0.100

--------------------------------------------------------------------------------
 
Bug 35589 - Default workspace does not include Strata flash file system support 
Bug#: 35589  Product: Scorpius  Version: 1.0.001  Platform: EP930X  
OS/Version: All  Status: RESOLVED  Severity: Major  Priority: P2  
Bug_Type: Test  Originator: Test  Version_Tested: 1.0.001  Win_CE_Version: CE .net 5.0  CE_Test_Kit_Version:   CE_Test_Name:   CE_Test_Kit_Failure_Test_Number_Field:   Nexus_Board_Number:   Nexus_Board_Type: EDB9315A  
Resolution: FIXED  Assigned To: xin.xing@cirrus.com  Reported By: fanlong.ran@cirrus.com  QA Contact:   
Component: Build Issues  Target Milestone: 1.0.100  
URL:   
Summary: Default workspace does not include Strata flash file system support  
Description:  

Version: 1.0.001
Board: EDB9301,EDB9302


Problem:
By default, the Support of Strata flash file system should be included in 
workspace. 
But now it is not. So after I download default BIN to board, 
I can not see "Hard Disk" directory when I use "dir" command.

------- Additional Comment #1 From xin xing 2005-07-14 03:49 ------- 
I could remember that there is no strara flash file system driver in edb9301/02 
sample project for Wince4.2. But since they support this driver, I'll add them.

------- Additional Comment #2 From xin xing 2005-07-14 03:51 ------- 
Strata flash file system driver is added to edb9301ship and edb9302ship.

------- Additional Comment #3 From Javier Montalvo 2005-07-20 10:21 ------- 
setting target milestone to 1.0.002

------- Additional Comment #4 From Javier Montalvo 2005-07-20 10:59 ------- 
setting to 1.0.100

--------------------------------------------------------------------------------
 
Bug 35590 - After remove the PCMCIA CFcard from PCMCIA slot, the icon <storage card> doesn't disappeared. 
Bug#: 35590  Product: Scorpius  Version: 1.0.001  Platform: EP931X  
OS/Version: Other  Status: NEW  Severity: Major  Priority: P2  
Bug_Type: Test  Originator: Development  Version_Tested: 1.0.001  Win_CE_Version: CE .net 5.0  CE_Test_Kit_Version:   CE_Test_Name:   CE_Test_Kit_Failure_Test_Number_Field:   Nexus_Board_Number: ED150057  Nexus_Board_Type: EDB9315A  
Resolution:   Assigned To: xin.xing@cirrus.com  Reported By: ping.jing@cirrus.com  QA Contact:   
Component: PCMCIA  Target Milestone: 1.0.100  
URL:   
Summary: After remove the PCMCIA CFcard from PCMCIA slot, the icon <storage card> doesn't disappeared.  
Description:  

Board: 9315 ED150057
Chip:  EP9312 - CB EFWAE1AB0515
Version: scorpius 1-0-001
How frequently: sometimes

Steps:

1, boot up the system by using the eboot.nb0 and nk.bin shipped with project.
2, insert the PCMCIA connector with CF card into PCMCIA slot, the icon <storage 
card> appeared.
3, remove the PCMCIA connector with CF card from PCMCIA slot.

result:
after step 3, sometimes the icon <storage card> doesn't disappeared, and you 
also may get in the  <storage card> folder.

------- Additional Comment #1 From Javier Montalvo 2005-07-20 10:21 ------- 
setting target milestone to 1.0.002

------- Additional Comment #2 From Javier Montalvo 2005-07-20 11:00 ------- 
setting to 1.0.100

--------------------------------------------------------------------------------
 
Bug 35591 - Web page for web server of 9301, 9302 is wrong 
Bug#: 35591  Product: Scorpius  Version: 1.0.001  Platform: EP930X  
OS/Version: All  Status: RESOLVED  Severity: Minor  Priority: P3  
Bug_Type: Test  Originator: Test  Version_Tested: 1.0.001  Win_CE_Version: CE .net 5.0  CE_Test_Kit_Version:   CE_Test_Name:   CE_Test_Kit_Failure_Test_Number_Field:   Nexus_Board_Number:   Nexus_Board_Type: EDB9315A  
Resolution: LATER  Assigned To: xin.xing@cirrus.com  Reported By: fanlong.ran@cirrus.com  QA Contact:   
Component: Build Issues  Target Milestone: 1.0.100  
URL:   
Summary: Web page for web server of 9301, 9302 is wrong  
Description:  

Version: 1.0.001
Board: EDB9301 EDB9302

Problem:
The web page for web server of EDB9301 and EDB9302 should be the description 
page about EDB9301 and EDB9302, but now it is for EDB9312. 


Steps:
1. Download NK.bin for EDB9301(EDB9302) to board
2. On PC, use IE to explore http://edb9301
3. See the web page for EDB9312 but not EDB9301(EDB9302)

------- Additional Comment #1 From xin xing 2005-07-14 04:47 ------- 
This page is only to demo the http server function. 

------- Additional Comment #2 From Melody Lee 2005-07-19 15:08 ------- 
We should create a generic html file for all EP93xx chips.

------- Additional Comment #3 From Melody Lee 2005-07-19 15:11 ------- 
Add a generic html file for all EP93xx chips in Scorpius 1.0.1.

------- Additional Comment #4 From Javier Montalvo 2005-07-20 10:21 ------- 
setting target milestone to 1.0.002

------- Additional Comment #5 From Javier Montalvo 2005-07-20 11:10 ------- 
setting to 1.0.100

--------------------------------------------------------------------------------
 
Bug 35592 - There are two warning massges were printed out when building the image. 
Bug#: 35592  Product: Scorpius  Version: 1.0.001  Platform: EP931X  
OS/Version: Other  Status: RESOLVED  Severity: Minor  Priority: P3  
Bug_Type: Test  Originator: Test  Version_Tested: 1.0.001  Win_CE_Version: CE .net 5.0  CE_Test_Kit_Version:   CE_Test_Name:   CE_Test_Kit_Failure_Test_Number_Field:   Nexus_Board_Number: ED150057  Nexus_Board_Type: EDB9315A  
Resolution: FIXED  Assigned To: xin.xing@cirrus.com  Reported By: ping.jing@cirrus.com  QA Contact:   
Component: Build Issues  Target Milestone: 1.0.100  
URL:   
Summary: There are two warning massges were printed out when building the image.  
Description:  

2, makeimg: Warning Localization FAILED: Could not find F:\WINCE500
\PBWorkspaces\EDB9315Ship\RelDir\ep93xx\edb9307_1x\..\..\ep93xx_ARMV4I_Release\t
svc_dst.DLL|EXE|CPL

This bug can't be fixed, it's caused by "SNTP Client with DST", and this feature
must be included, the "standard stell" depends on it.
the bug still exists, even all feature in SNTP are added,
so it can't be fixed.

Braden

------- Additional Comment #1 From [BJ] Daniel Jing 2005-07-14 03:56 ------- 
Version: scorpius 1-0-001
How frequently: Always

Steps:

1, double click file ep93xx_bsp_for_wince_5.0.msi to setup BSP for project.
2, copy the EDB9315Ship under PBworkspace
3, open the project by using PB5.0
4, on PB5.0, choose --> build OS --> sysgen to build image.

result:

two warning messages were printed out in PB:

1, BUILD: [01:0000000310:WARNN ] f:\WINCE500
\PLATFORM\ep93xx\src\drivers\atapi\ep931xide.cpp(2181) : warning C4002: too 
many actual parameters for macro 'DEBUGMSG'

2, makeimg: Warning Localization FAILED: Could not find F:\WINCE500
\PBWorkspaces\EDB9315Ship\RelDir\ep93xx\edb9307_1x\..\..\ep93xx_ARMV4I_Release\t
svc_dst.DLL|EXE|CPL

------- Additional Comment #2 From xin xing 2005-07-14 04:55 ------- 
The first type of waring has been fixed by Braden.

1, BUILD: [01:0000000310:WARNN ] f:\WINCE500
\PLATFORM\ep93xx\src\drivers\atapi\ep931xide.cpp(2181) : warning C4002: too 
many actual parameters for macro 'DEBUGMSG'



------- Additional Comment #3 From Javier Montalvo 2005-07-20 10:21 ------- 
setting target milestone to 1.0.002

------- Additional Comment #4 From Javier Montalvo 2005-07-20 11:03 ------- 
setting to 1.0.100

--------------------------------------------------------------------------------
 
Bug 35594 - Can not exit Transcriber Program after start up it 
Bug#: 35594  Product: Scorpius  Version: 1.0.001  Platform: EP931X  
OS/Version: All  Status: NEW  Severity: Major  Priority: P2  
Bug_Type: Test  Originator: Test  Version_Tested: 1.0.001  Win_CE_Version: CE .net 5.0  CE_Test_Kit_Version:   CE_Test_Name:   CE_Test_Kit_Failure_Test_Number_Field:   Nexus_Board_Number:   Nexus_Board_Type: EDB9315A  
Resolution:   Assigned To: xin.xing@cirrus.com  Reported By: fanlong.ran@cirrus.com  QA Contact:   
Component: Other System Issues  Target Milestone: 1.0.100  
URL:   
Summary: Can not exit Transcriber Program after start up it  
Description:  

Version: 1.0.001
Board: EDB9307 EDB9312 EDB9315

Problem:
We can start up Transcriber Program via double click the Transcriber Icon on 
the Desktop of Board successfully. But we can not exit it after that.

Steps:
1. Download NK.bin to Target Board
2. Double click "Transcriber Icon" on the Desktop of Board to start up it
3. We can not exit "Transcriber Program" now

------- Additional Comment #1 From Javier Montalvo 2005-07-20 10:21 ------- 
setting target milestone to 1.0.002

------- Additional Comment #2 From Javier Montalvo 2005-07-20 11:00 ------- 
setting to 1.0.100

--------------------------------------------------------------------------------
 
Bug 35595 - CETK - Waveform Audio Driver Test - 4000: Test Volume Control - failed 
Bug#: 35595  Product: Scorpius  Version: 1.0.001  Platform: EP931X  
OS/Version: Other  Status: REOPENED  Severity: Major  Priority: P2  
Bug_Type: Test  Originator: Test  Version_Tested: 1.0.001  Win_CE_Version: CE .net 5.0  CE_Test_Kit_Version: CETK5.0  CE_Test_Name: Waveform Audio Driver Test  CE_Test_Kit_Failure_Test_Number_Field: 4000: Test Volume Control  Nexus_Board_Number: ED150057  Nexus_Board_Type: EDB9315A  
Resolution:   Assigned To: xin.xing@cirrus.com  Reported By: ping.jing@cirrus.com  QA Contact:   
Component: Wave Device Driver  Target Milestone: 1.0.100  
URL:   
Summary: CETK - Waveform Audio Driver Test - 4000: Test Volume Control - failed  
Description:  

This bug can be reproduced.

------- Additional Comment #1 From xin xing 2003-05-19 06:55 ------- 
This is not a bug. The abortion is caused by an unsupported feature. There is 
some difference in the implementation of volumn control between WinCE4.2 and 
WinCE5.0. The supporting code for this new feature won't be provided till after 
scorpius version 1-0-1. While, current version is only 1-0-0. Therefore, this 
bug is marked later-fix now. Perhaps the milestone will be version 1-1-0 or 1-0-
2.

------- Additional Comment #2 From [BJ] Daniel Jing 2005-07-14 04:16 ------- 
Board: 9315 ED150057
Chip:  EP9312 - CB EFWAE1AB0515
Version: scorpius 1-0-001
How frequently: Always

Steps:

1, boot up the system by using the eboot.nb0 and nk.bin shipped with project.
2, connect cetk server pc from board.
3, run  Waveform Audio Driver Test 

result: case 4000: Test Volume Control - aborted

result log:

<TESTCASE ID=4000>
*** vvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvv
*** TEST STARTING
***
*** Test Name:      Test Volume Control
*** Test ID:        4000
*** Library Path:   \wavetest.dll
*** Command Line:
*** Random Seed:    13775
*** Thread Count:   0
*** vvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvv
   BEGIN TEST: "Test Volume Control", Threads=0, Seed=13775
       Case #0: Setting Volume to 0.55 to have conistent starting volume.
       Case #0: The first ring you hear is just letting you hear the starting 
volume.
      SetOrGetVolume: set volume=0.5
      mixerOpen failed with result = 6
      
       Case #1: Setting Volume to 1.0
      SetOrGetVolume: set volume=1.0
      mixerOpen failed with result = 6
      mixerOpen failed with result = 6
      
       Case #2: Setting Volume to 0.55
      SetOrGetVolume: set volume=0.5
      mixerOpen failed with result = 6
      mixerOpen failed with result = 6
      
       Case #3: Setting Volume to 0.1
       This is very low, you may want to turn up your speakers for this one
      SetOrGetVolume: set volume=0.1
      mixerOpen failed with result = 6
      mixerOpen failed with result = 6
      
       Case #4: Setting Volume to 0.9
      SetOrGetVolume: set volume=0.9
      mixerOpen failed with result = 6
      mixerOpen failed with result = 6
      
       Case #5: Setting Volume to 0.0 (MUTED)
      SetOrGetVolume: set volume=0.0
      mixerOpen failed with result = 6
      mixerOpen failed with result = 6
      
   END TEST: "Test Volume Control", ABORTED, Time=0.305