📄 rfc1907.txt
字号:
`badValue'." ::= { snmp 10 }snmpInReadOnlys OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The total number valid SNMP PDUs which were delivered to the SNMP protocol entity and for which the value of the error-status field is `readOnly'. It should be noted that it is a protocol error to generate an SNMP PDU which contains the value `readOnly' in the error-status field, as such this object is provided as a means of detecting incorrect implementations of the SNMP." ::= { snmp 11 }snmpInGenErrs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The total number of SNMP PDUs which were delivered to the SNMP protocol entity and for which the value of the error-status field is `genErr'." ::= { snmp 12 }snmpInTotalReqVars OBJECT-TYPE SYNTAX Counter32SNMPv2 Working Group Standards Track [Page 14]RFC 1907 Management Information Base for SNMPv2 January 1996 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The total number of MIB objects which have been retrieved successfully by the SNMP protocol entity as the result of receiving valid SNMP Get-Request and Get-Next PDUs." ::= { snmp 13 }snmpInTotalSetVars OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The total number of MIB objects which have been altered successfully by the SNMP protocol entity as the result of receiving valid SNMP Set-Request PDUs." ::= { snmp 14 }snmpInGetRequests OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The total number of SNMP Get-Request PDUs which have been accepted and processed by the SNMP protocol entity." ::= { snmp 15 }snmpInGetNexts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The total number of SNMP Get-Next PDUs which have been accepted and processed by the SNMP protocol entity." ::= { snmp 16 }snmpInSetRequests OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The total number of SNMP Set-Request PDUs which have been accepted and processed by the SNMP protocol entity."SNMPv2 Working Group Standards Track [Page 15]RFC 1907 Management Information Base for SNMPv2 January 1996 ::= { snmp 17 }snmpInGetResponses OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The total number of SNMP Get-Response PDUs which have been accepted and processed by the SNMP protocol entity." ::= { snmp 18 }snmpInTraps OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The total number of SNMP Trap PDUs which have been accepted and processed by the SNMP protocol entity." ::= { snmp 19 }snmpOutTooBigs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The total number of SNMP PDUs which were generated by the SNMP protocol entity and for which the value of the error-status field is `tooBig.'" ::= { snmp 20 }snmpOutNoSuchNames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The total number of SNMP PDUs which were generated by the SNMP protocol entity and for which the value of the error-status is `noSuchName'." ::= { snmp 21 }snmpOutBadValues OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS obsoleteSNMPv2 Working Group Standards Track [Page 16]RFC 1907 Management Information Base for SNMPv2 January 1996 DESCRIPTION "The total number of SNMP PDUs which were generated by the SNMP protocol entity and for which the value of the error-status field is `badValue'." ::= { snmp 22 }-- { snmp 23 } is not usedsnmpOutGenErrs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The total number of SNMP PDUs which were generated by the SNMP protocol entity and for which the value of the error-status field is `genErr'." ::= { snmp 24 }snmpOutGetRequests OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The total number of SNMP Get-Request PDUs which have been generated by the SNMP protocol entity." ::= { snmp 25 }snmpOutGetNexts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The total number of SNMP Get-Next PDUs which have been generated by the SNMP protocol entity." ::= { snmp 26 }snmpOutSetRequests OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The total number of SNMP Set-Request PDUs which have been generated by the SNMP protocol entity." ::= { snmp 27 }SNMPv2 Working Group Standards Track [Page 17]RFC 1907 Management Information Base for SNMPv2 January 1996snmpOutGetResponses OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The total number of SNMP Get-Response PDUs which have been generated by the SNMP protocol entity." ::= { snmp 28 }snmpOutTraps OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The total number of SNMP Trap PDUs which have been generated by the SNMP protocol entity." ::= { snmp 29 }snmpObsoleteGroup OBJECT-GROUP OBJECTS { snmpOutPkts, snmpInTooBigs, snmpInNoSuchNames, snmpInBadValues, snmpInReadOnlys, snmpInGenErrs, snmpInTotalReqVars, snmpInTotalSetVars, snmpInGetRequests, snmpInGetNexts, snmpInSetRequests, snmpInGetResponses, snmpInTraps, snmpOutTooBigs, snmpOutNoSuchNames, snmpOutBadValues, snmpOutGenErrs, snmpOutGetRequests, snmpOutGetNexts, snmpOutSetRequests, snmpOutGetResponses, snmpOutTraps } STATUS obsolete DESCRIPTION "A collection of objects from RFC 1213 made obsolete by this MIB." ::= { snmpMIBGroups 10 }END3. Security Considerations Security issues are not discussed in this memo.SNMPv2 Working Group Standards Track [Page 18]RFC 1907 Management Information Base for SNMPv2 January 19964. Editor's Address Keith McCloghrie Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 US Phone: +1 408 526 5260 EMail: kzm@cisco.com5. Acknowledgements This document is the result of significant work by the four major contributors: Jeffrey D. Case (SNMP Research, case@snmp.com) Keith McCloghrie (Cisco Systems, kzm@cisco.com) Marshall T. Rose (Dover Beach Consulting, mrose@dbc.mtview.ca.us) Steven Waldbusser (International Network Services, stevew@uni.ins.com) In addition, the contributions of the SNMPv2 Working Group are acknowledged. In particular, a special thanks is extended for the contributions of: Alexander I. Alten (Novell) Dave Arneson (Cabletron) Uri Blumenthal (IBM) Doug Book (Chipcom) Kim Curran (Bell-Northern Research) Jim Galvin (Trusted Information Systems) Maria Greene (Ascom Timeplex) Iain Hanson (Digital) Dave Harrington (Cabletron) Nguyen Hien (IBM) Jeff Johnson (Cisco Systems) Michael Kornegay (Object Quest) Deirdre Kostick (AT&T Bell Labs) David Levi (SNMP Research) Daniel Mahoney (Cabletron) Bob Natale (ACE*COMM) Brian O'Keefe (Hewlett Packard) Andrew Pearson (SNMP Research) Dave Perkins (Peer Networks) Randy Presuhn (Peer Networks) Aleksey Romanov (Quality Quorum) Shawn Routhier (Epilogue) Jon Saperia (BGS Systems)SNMPv2 Working Group Standards Track [Page 19]RFC 1907 Management Information Base for SNMPv2 January 1996 Bob Stewart (Cisco Systems, bstewart@cisco.com), chair Kaj Tesink (Bellcore) Glenn Waters (Bell-Northern Research) Bert Wijnen (IBM)6. References[1] Information processing systems - Open Systems Interconnection - Specification of Abstract Syntax Notation One (ASN.1), International Organization for Standardization. International Standard 8824, (December, 1987).[2] SNMPv2 Working Group, Case, J., McCloghrie, K., Rose, M., and S. Waldbusser, "Structure of Management Information for Version 2 of the Simple Network Management Protocol (SNMPv2)", RFC 1902, January 1996.[3] SNMPv2 Working Group, Case, J., McCloghrie, K., Rose, M., and S. Waldbusser, "Protocol Operations for Version 2 of the Simple Network Management Protocol (SNMPv2)", RFC 1905, January 1996.[4] J.D. Case, C. Partridge, Case Diagrams: A First Step to Diagramed Management Information Bases. Computer Communications Review, Volume 19, Number 1, (January, 1989).SNMPv2 Working Group Standards Track [Page 20]
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -