📄 psocconfigtbl.lis

📁 Summary Many control applications require converting some analog input to a digital format. The ADC
💻 LIS
字号:
 0000           ;  Personalization tables 
                export LoadConfigTBL_adcinc12_asm_example_Bank1
                export LoadConfigTBL_adcinc12_asm_example_Bank0
 0000           LoadConfigTBL_adcinc12_asm_example_Bank1:
 0000           ;  Global Register values
 0000 6100              db              61h, 00h                ; AnalogClockSelect register
 0002 6001              db              60h, 01h                ; AnalogColumnClockSelect register
 0004 6200              db              62h, 00h                ; AnalogIOControl register
 0006 6300              db              63h, 00h                ; AnalogModulatorControl register
 0008 E153              db              e1h, 53h                ; OscillatorControl_1 register
 000A 00FF              db              00h, ffh                ; Port_0_DriveMode_0 register
 000C 0100              db              01h, 00h                ; Port_0_DriveMode_1 register
 000E 0200              db              02h, 00h                ; Port_0_IntCtrl_0 register
 0010 0300              db              03h, 00h                ; Port_0_IntCtrl_1 register
 0012 04FF              db              04h, ffh                ; Port_1_DriveMode_0 register
 0014 0500              db              05h, 00h                ; Port_1_DriveMode_1 register
 0016 0600              db              06h, 00h                ; Port_1_IntCtrl_0 register
 0018 0701              db              07h, 01h                ; Port_1_IntCtrl_1 register
 001A 0804              db              08h, 04h                ; Port_2_DriveMode_0 register
 001C 0902              db              09h, 02h                ; Port_2_DriveMode_1 register
 001E 0A00              db              0ah, 00h                ; Port_2_IntCtrl_0 register
 0020 0B00              db              0bh, 00h                ; Port_2_IntCtrl_1 register
 0022 0C00              db              0ch, 00h                ; Port_3_DriveMode_0 register
 0024 0D00              db              0dh, 00h                ; Port_3_DriveMode_1 register
 0026 0E00              db              0eh, 00h                ; Port_3_IntCtrl_0 register
 0028 0F00              db              0fh, 00h                ; Port_3_IntCtrl_1 register
 002A 1000              db              10h, 00h                ; Port_4_DriveMode_0 register
 002C 1100              db              11h, 00h                ; Port_4_DriveMode_1 register
 002E 1200              db              12h, 00h                ; Port_4_IntCtrl_0 register
 0030 1300              db              13h, 00h                ; Port_4_IntCtrl_1 register
 0032 1400              db              14h, 00h                ; Port_5_DriveMode_0 register
 0034 1500              db              15h, 00h                ; Port_5_DriveMode_1 register
 0036 1600              db              16h, 00h                ; Port_5_IntCtrl_0 register
 0038 1700              db              17h, 00h                ; Port_5_IntCtrl_1 register
 003A E387              db              e3h, 87h                ; VoltageMonitorControl register
 003C           ;  Instance name ADCINC12_1, User Module ADCINC12
 003C           ;       Instance name ADCINC12_1, Block Name ADC(ASB20)
 003C           ;       Instance name ADCINC12_1, Block Name CNT(DBA01)
 003C 2421              db              24h, 21h                ;ADCINC12_1_CounterFN
 003E 2546              db              25h, 46h                ;ADCINC12_1_CounterSL
 0040 2600              db              26h, 00h                ;ADCINC12_1_CounterOS
 0042           ;       Instance name ADCINC12_1, Block Name TMR(DBA00)
 0042 2020              db              20h, 20h                ;ADCINC12_1_TimerFN
 0044 2116              db              21h, 16h                ;ADCINC12_1_TimerSL
 0046 2200              db              22h, 00h                ;ADCINC12_1_TimerOS
 0048 FF                db              ffh
 0049           LoadConfigTBL_adcinc12_asm_example_Bank0:
 0049           ;  Global Register values
 0049 6028              db              60h, 28h                ; AnalogColumnInputSelect register
 004B 6307              db              63h, 07h                ; AnalogReferenceControl register
 004D 6500              db              65h, 00h                ; AnalogSyncControl register
 004F E600              db              e6h, 00h                ; DecimatorControl register
 0051 0200              db              02h, 00h                ; Port_0_Bypass register
 0053 0100              db              01h, 00h                ; Port_0_IntEn register
 0055 0600              db              06h, 00h                ; Port_1_Bypass register
 0057 0501              db              05h, 01h                ; Port_1_IntEn register
 0059 0A00              db              0ah, 00h                ; Port_2_Bypass register
 005B 0900              db              09h, 00h                ; Port_2_IntEn register
 005D 0E00              db              0eh, 00h                ; Port_3_Bypass register
 005F 0D00              db              0dh, 00h                ; Port_3_IntEn register
 0061 1200              db              12h, 00h                ; Port_4_Bypass register
 0063 1100              db              11h, 00h                ; Port_4_IntEn register
 0065 1600              db              16h, 00h                ; Port_5_Bypass register
 0067 1500              db              15h, 00h                ; Port_5_IntEn register
 0069           ;  Instance name ADCINC12_1, User Module ADCINC12
 0069           ;       Instance name ADCINC12_1, Block Name ADC(ASB20)
 0069 9090              db              90h, 90h                ;ADCINC12_1_AtoDcr0
 006B 9120              db              91h, 20h                ;ADCINC12_1_AtoDcr1
 006D 9260              db              92h, 60h                ;ADCINC12_1_AtoDcr2
 006F 93F0              db              93h, f0h                ;ADCINC12_1_AtoDcr3
 0071           ;       Instance name ADCINC12_1, Block Name CNT(DBA01)
 0071 2700              db              27h, 00h                ;ADCINC12_1_CounterCR0
 0073 2500              db              25h, 00h                ;ADCINC12_1_CounterDR1
 0075 2600              db              26h, 00h                ;ADCINC12_1_CounterDR2
 0077           ;       Instance name ADCINC12_1, Block Name TMR(DBA00)
 0077 2300              db              23h, 00h                ;ADCINC12_1_TimerCR0
 0079 2100              db              21h, 00h                ;ADCINC12_1_TimerDR1
 007B 2200              db              22h, 00h                ;ADCINC12_1_TimerDR2
 007D FF                db              ffh
 007E           
 007E           
 007E           ; PSoC Configuration file trailer PsocConfig.asm