📄 formstar.pas
字号:
unit Formstar;
interface
uses
Windows, Messages, SysUtils, Classes, Graphics, Controls, Forms, Dialogs,
StdCtrls, Driver, Global;
type
Tfrmstart = class(TForm)
labSelDev: TLabel;
lstDevice: TListBox;
labModule: TLabel;
lstModule: TListBox;
cmdRun: TButton;
labChannel: TLabel;
lstChannel: TListBox;
cmdExit: TButton;
labHighAlarm: TLabel;
labLowAlarm: TLabel;
labLatchMode: TLabel;
txtHighAlarm: TEdit;
cmdLatMode: TButton;
txtLowAlarm: TEdit;
procedure cmdExitClick(Sender: TObject);
procedure cmdRunClick(Sender: TObject);
procedure FormCreate(Sender: TObject);
procedure lstDeviceClick(Sender: TObject);
procedure lstModuleClick(Sender: TObject);
procedure cmdLatModeClick(Sender: TObject);
private
{ Private declarations }
public
{ Public declarations }
end;
var
frmstart: Tfrmstart;
implementation
uses formrun;
var
lpDevFeatures : DEVFEATURES;
lpDevConfig_AI : DEVCONFIG_AI;
gnNumOfSubdevices : Smallint;
Response : Integer;
{$R *.DFM}
procedure Tfrmstart.cmdExitClick(Sender: TObject);
begin
if bRun then
DRV_DeviceClose(DeviceHandle);
close;
end;
procedure Tfrmstart.cmdRunClick(Sender: TObject);
var
tempNum : Integer;
LatchMode : Integer;
code : Integer;
begin
AlarmChan := lstChannel.ItemIndex;
ptAlarmConfig.chan := AlarmChan;
Val(txtHighAlarm.Text, ptAlarmConfig.HiLimit, code);
Val(txtLowAlarm.Text, ptAlarmConfig.LoLimit, code);
{ Wait for 4 second }
ErrCde := DRV_AlarmConfig(DeviceHandle, ptAlarmConfig);
If (ErrCde <> 0) Then
begin
DRV_GetErrorMessage(ErrCde, pszErrMsg);
Response := Application.MessageBox(pszErrMsg, 'Error!!', MB_OK);
Exit;
end;
If cmdLatMode.Caption = 'Latch' Then
LatchMode := 0
Else
LatchMode := 1;
ptAlarmEnable.chan := AlarmChan;
ptAlarmEnable.LatchMode := LatchMode;
ptAlarmEnable.enabled := 1; { enable alarm }
ErrCde := DRV_AlarmEnable(DeviceHandle, ptAlarmEnable);
If (ErrCde <> 0) Then
begin
DRV_GetErrorMessage(ErrCde, pszErrMsg);
Response := Application.MessageBox(pszErrMsg, 'Error!!', MB_OK);
Exit;
end;
FormRun.frmRun.Show;
Formrun.frmrun.tmrRead.Enabled := True;
end;
procedure Tfrmstart.FormCreate(Sender: TObject);
var
OutEntries : Smallint;
NumOfDevice : Smallint;
i, j : Integer;
tempStr : String;
testRes : boolean;
begin
bRun := False;
txtHighAlarm.Text := IntToStr(30);
txtLowAlarm.Text := IntToStr(10);
{ Add type of PC Laboratory Card }
ErrCde := DRV_DeviceGetList(DeviceList[0], MaxEntries, OutEntries);
If (ErrCde <> 0) Then
begin
DRV_GetErrorMessage(ErrCde, pszErrMsg);
Response := Application.MessageBox(pszErrMsg, 'Error!!', MB_OK);
Exit;
end;
{ Here MaxEntries = OutEntries }
ErrCde := DRV_DeviceGetNumOfList(NumOfDevice);
If (ErrCde <> 0) Then
begin
DRV_GetErrorMessage(ErrCde, pszErrMsg);
Response := Application.MessageBox(pszErrMsg, 'Error!!', MB_OK);
Exit;
end;
For i := 0 To (NumOfDevice - 1) do
begin
tempStr := '';
For j := 0 To MaxDevNameLen do
tempStr := tempStr + DeviceList[i].szDeviceName[j];
lstDevice.Items.Add(tempStr);
end;
{ Disable module in this example }
lstModule.Enabled := False;
labModule.Enabled := False;
labChannel.Enabled := False;
lstChannel.Enabled := False;
{lstVoltageRange.Enabled := False;}
{labVoltageRange.Enabled := False;}
cmdRun.Enabled := False;
end;
procedure Tfrmstart.lstDeviceClick(Sender: TObject);
var
tempNum, i, ii : Integer;
nOutEntries : Smallint;
TestRes : Boolean;
TempStr : String;
dwDeviceNum : Longint;
lpAIGetConfig : PT_AIGetConfig;
lpDEVCONFIG_AI : DEVCONFIG_AI;
begin
lstModule.Items.Clear;
lstChannel.Items.Clear;
{lstVoltageRange.Items.Clear;}
{lstExpChl.Clear;}
tempNum := Pos('DEMO', lstDevice.Items[lstDevice.ItemIndex]);
if (tempNum <> 0) then
TestRes := True
else
TestRes := False;
{ Avoid to open Advantech Demo Card }
If (TestRes) Then
begin
labModule.Enabled := False;
lstModule.Enabled := False;
labChannel.Enabled := False;
lstChannel.Enabled := False;
{labVoltageRange.Enabled := False;}
{lstVoltageRange.Enabled := False;}
{labExpChl.Enabled := False;}
{lstExpChl.Enabled := False;}
{labThermoCouple.Enabled := False;}
{lstThermoCouple.Enabled := False;}
lstChannel.Items.Add('No Use');
cmdRun.Enabled := False;
end;
If (Not TestRes) Then
begin
{ Check if there is any device attached on this COM or CAN }
gnNumOfSubdevices := DeviceList[lstDevice.ItemIndex].nNumOfSubdevices;
if (gnNumOfSubdevices > MaxDev) then
gnNumOfSubdevices := MaxDev;
dwDeviceNum := DeviceList[lstDevice.ItemIndex].dwDeviceNum;
{ COM and CAN bus }
if (gnNumOfSubdevices <> 0) then
begin
ErrCde := DRV_DeviceGetSubList(dwDeviceNum, SubDeviceList[0], gnNumOfSubdevices, nOutEntries);
If (ErrCde <> 0) Then
begin
DRV_GetErrorMessage(ErrCde, pszErrMsg);
Response := Application.MessageBox(pszErrMsg, 'Error!!', MB_OK);
Exit;
end;
For i := 0 To (gnNumOfSubdevices - 1) do
begin
tempStr := '';
For ii := 0 To MaxDevNameLen do
tempStr := tempStr + SubDevicelist[i].szDeviceName[ii];
lstModule.Items.Add(tempStr);
end;
lstModule.Enabled := True;
labModule.Enabled := True;
labChannel.Enabled := True;
lstChannel.Enabled := True;
{labVoltageRange.Enabled := True;}
{lstVoltageRange.Enabled := True;}
cmdRun.Enabled := True;
end;
{ PCL DAS & DIO card }
if (gnNumOfSubdevices = 0) then
begin
ErrCde := DRV_DeviceOpen(dwDeviceNum, DeviceHandle);
If (ErrCde <> 0) Then
begin
DRV_GetErrorMessage(ErrCde, pszErrMsg);
Response := Application.MessageBox(pszErrMsg, 'Error!!', MB_OK);
Exit;
end
else
bRun := True;
ptDevGetFeatures.buffer := @lpDevFeatures;
ErrCde := DRV_DeviceGetFeatures(DeviceHandle, ptDevGetFeatures);
{ Add analog input channel item for alarm input}
lpAIGetConfig.buffer := @lpDevConfig_AI;
ErrCde := DRV_AIGetConfig(DeviceHandle, lpAIGetConfig);
If (ErrCde <> 0) Then
begin
DRV_GetErrorMessage(ErrCde, pszErrMsg);
Response := Application.MessageBox(pszErrMsg, 'Error!!', MB_OK);
DRV_DeviceClose(DeviceHandle);
Exit;
end;
If (lpDevConfig_AI.ulChanConfig = 0) Then
tempNum := lpDevFeatures.usMaxAISiglChl
Else
tempNum := lpDevFeatures.usMaxAIDiffChl;
if (tempNum > 0) then
begin
For i := 0 To (tempNum - 1) do
begin
tempStr := 'Chan#' + IntToStr(i);
lstChannel.Items.Add(tempStr);
end;
labChannel.Enabled := True;
lstChannel.Enabled := True;
{lstChannel.Text := lstChannel.Items[0];}
end;
{ Since you have selected a PC-Lab Card, you can choose the channel and gain code as you want}
cmdRun.Enabled := True;
end;
end;
end;
procedure Tfrmstart.lstModuleClick(Sender: TObject);
var
tempNum, i, ii : Integer;
dwDeviceNum : Longint;
TempStr : String;
begin
lstChannel.Items.Clear;
{lstVoltageRange.Items.Clear;}
{lstExpChl.Clear;}
{ open COM device or CAN device }
dwDeviceNum := SubDevicelist[lstModule.ItemIndex].dwDeviceNum;
ErrCde := DRV_DeviceOpen(dwDeviceNum, DeviceHandle);
If (ErrCde <> 0) Then
begin
DRV_GetErrorMessage(ErrCde, pszErrMsg);
Response := Application.MessageBox(pszErrMsg, 'Error!!', MB_OK);
Exit;
end
Else
bRun := True;
ptDevGetFeatures.buffer := @lpDevFeatures;
ErrCde := DRV_DeviceGetFeatures(DeviceHandle, ptDevGetFeatures);
If (ErrCde <> 0) Then
begin
DRV_GetErrorMessage(ErrCde, pszErrMsg);
Response := Application.MessageBox(pszErrMsg, 'Error!!', MB_OK);
Exit;
end;
ptAIGetConfig.buffer := @lpDevConfig_AI;
ErrCde := DRV_AIGetConfig(DeviceHandle, ptAIGetConfig);
If (ErrCde <> 0) Then
begin
DRV_GetErrorMessage(ErrCde, pszErrMsg);
Response := Application.MessageBox(pszErrMsg, 'Error!!', MB_OK);
DRV_DeviceClose(DeviceHandle);
Exit;
end;
{ Add analog input channel item for alarm input}
If (lpDevConfig_AI.ulChanConfig = 0) Then
tempNum := lpDevFeatures.usMaxAISiglChl
Else
tempNum := lpDevFeatures.usMaxAIDiffChl;
For i := 0 To (tempNum - 1) do
begin
tempStr := 'Chan#' + IntToStr(i);
lstChannel.Items.Add(tempStr);
end;
cmdRun.enabled := True;
{ WARNING : No gain code list for ADAM series}
end;
procedure Tfrmstart.cmdLatModeClick(Sender: TObject);
begin
If cmdLatMode.Caption = 'Latch' Then
cmdLatMode.Caption := 'Momentary'
Else
cmdLatMode.Caption := 'Latch';
end;
end.