<p class=MsoNormal style='line-height:18.0pt;mso-layout-grid-align:none'><span
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'><span
style="mso-spacerun: yes"> </span></span><span lang=ZH-CN
style='font-family:宋体;mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:
"Times New Roman"'>二、电缆型号、规格、长度应符合订货要求,附件应齐全;电缆外观不应受</span><span lang=ZH-CN
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'> </span><span
lang=ZH-CN style='font-family:宋体;mso-ascii-font-family:"Times New Roman";
mso-hansi-font-family:"Times New Roman"'>损。</span><span lang=ZH-CN
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'> </span><span
style='mso-bidi-font-size:10.0pt'><o:p></o:p></span></p>
<p class=MsoNormal style='line-height:18.0pt;mso-layout-grid-align:none'><span
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'><span
style="mso-spacerun: yes"> </span></span><span lang=ZH-CN
style='font-family:宋体;mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:
"Times New Roman"'>三、电缆封端应严密。当外观检查有怀疑时,应进行受潮判断或试验。</span><span lang=ZH-CN
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'> </span><span
style='mso-bidi-font-size:10.0pt'><o:p></o:p></span></p>
<p class=MsoNormal style='line-height:18.0pt;mso-layout-grid-align:none'><span
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'><span
style="mso-spacerun: yes"> </span></span><span lang=ZH-CN
style='font-family:宋体;mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:
"Times New Roman"'>四、充油电缆的压力油箱、油管、阀门和压力表应符合要求且完好无损。</span><span lang=ZH-CN
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'> </span><span
style='mso-bidi-font-size:10.0pt'><o:p></o:p></span></p>
<p class=MsoNormal style='line-height:18.0pt;mso-layout-grid-align:none'><span
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'><span
style="mso-spacerun: yes"> </span></span><span lang=ZH-CN
style='font-family:宋体;mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:
"Times New Roman"'>第</span>2.0.4<span lang=ZH-CN style='font-family:宋体;
mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:"Times New Roman"'>条</span><span
lang=ZH-CN style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'> </span><span
lang=ZH-CN style='font-family:宋体;mso-ascii-font-family:"Times New Roman";
mso-hansi-font-family:"Times New Roman"'>电缆及其有关材料如不立即安装,应按下列要求贮存:</span><span
lang=ZH-CN style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'> </span><span
style='mso-bidi-font-size:10.0pt'><o:p></o:p></span></p>
<p class=MsoNormal style='line-height:18.0pt;mso-layout-grid-align:none'><span
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'><span
style="mso-spacerun: yes"> </span></span><span lang=ZH-CN
style='font-family:宋体;mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:
"Times New Roman"'>一、电缆应集中分类存放,并应标明型号、电压、规格、长度。电缆盘之间应有通道。地基应坚实,当受条件限制时,盘下应加垫,存放处不得积水。</span><span
lang=ZH-CN style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'> </span><span
style='mso-bidi-font-size:10.0pt'><o:p></o:p></span></p>
<p class=MsoNormal style='line-height:18.0pt;mso-layout-grid-align:none'><span
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'><span
style="mso-spacerun: yes"> </span></span><span lang=ZH-CN
style='font-family:宋体;mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:
"Times New Roman"'>二、电缆终端瓷套在贮存时,应有防止受机械损伤的措施。</span><span lang=ZH-CN
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'> </span><span
style='mso-bidi-font-size:10.0pt'><o:p></o:p></span></p>
<p class=MsoNormal style='line-height:18.0pt;mso-layout-grid-align:none'><span
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'><span
style="mso-spacerun: yes"> </span></span><span lang=ZH-CN
style='font-family:宋体;mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:
"Times New Roman"'>三、电缆附件的绝缘材料的防潮包装应密封良好,并应根据材料性能和保管要求贮存和保管。</span><span
lang=ZH-CN style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'> </span><span
style='mso-bidi-font-size:10.0pt'><o:p></o:p></span></p>
<p class=MsoNormal style='line-height:18.0pt;mso-layout-grid-align:none'><span
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'><span
style="mso-spacerun: yes"> </span></span><span lang=ZH-CN
style='font-family:宋体;mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:
"Times New Roman"'>四、防火涂料、包带、堵料等防火材料,应根据材料性能和保管要求贮存和保管。</span><span lang=ZH-CN
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'> </span><span
style='mso-bidi-font-size:10.0pt'><o:p></o:p></span></p>
<p class=MsoNormal style='line-height:18.0pt;mso-layout-grid-align:none'><span
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'><span
style="mso-spacerun: yes"> </span></span><span lang=ZH-CN
style='font-family:宋体;mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:
"Times New Roman"'>五、电缆桥架应分类保管,不得因受力变形。</span><span lang=ZH-CN
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'> </span><span
style='mso-bidi-font-size:10.0pt'><o:p></o:p></span></p>
<p class=MsoNormal style='line-height:18.0pt;mso-layout-grid-align:none'><span
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'><span
style="mso-spacerun: yes"> </span></span><span lang=ZH-CN
style='font-family:宋体;mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:
"Times New Roman"'>第</span>2.0.5<span lang=ZH-CN style='font-family:宋体;
mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:"Times New Roman"'>条</span><span
lang=ZH-CN style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'> </span><span
lang=ZH-CN style='font-family:宋体;mso-ascii-font-family:"Times New Roman";
mso-hansi-font-family:"Times New Roman"'>电缆在保管期间,电缆盘及包装应完好,标志应齐全,封端应严密。当有缺陷时,应及时处理。</span><span
lang=ZH-CN style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'> </span><span
style='mso-bidi-font-size:10.0pt'><o:p></o:p></span></p>
<p class=MsoNormal style='line-height:18.0pt;mso-layout-grid-align:none'><span
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'><span
style="mso-spacerun: yes"> </span></span><span lang=ZH-CN
style='font-family:宋体;mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:
"Times New Roman"'>充油电缆应经常检查油压,并作记录,油压不得降至最低值。当油压降至零或出现真空时,应及时处理。</span><span
lang=ZH-CN style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'> </span><span
style='mso-bidi-font-size:10.0pt'><o:p></o:p></span></p>
<P class=MsoNormal align=center style='text-align:center;line-height:18.0pt;
mso-layout-grid-align:none'><span lang=ZH-CN style='font-family:宋体;mso-ascii-font-family:
"Times New Roman";mso-hansi-font-family:"Times New Roman"'><A NAME="A3"></A>第三章</span><span
lang=ZH-CN style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'> </span><span
lang=ZH-CN style='font-family:宋体;mso-ascii-font-family:"Times New Roman";
mso-hansi-font-family:"Times New Roman"'>电缆管的加工及敷设</span><span lang=ZH-CN
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'> </span><span
style='mso-bidi-font-size:10.0pt'><o:p></o:p></span></P>
<p class=MsoNormal align=left style='text-align:left;line-height:18.0pt;
mso-layout-grid-align:none'><span style='font-family:宋体;mso-hansi-font-family:
"Times New Roman"'><span style="mso-spacerun: yes"> </span></span><span
lang=ZH-CN style='font-family:宋体;mso-ascii-font-family:"Times New Roman";
mso-hansi-font-family:"Times New Roman"'>第</span>3.0.1<span lang=ZH-CN
style='font-family:宋体;mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:
"Times New Roman"'>条</span><span lang=ZH-CN style='font-family:宋体;mso-hansi-font-family:
"Times New Roman"'> </span><span lang=ZH-CN style='font-family:宋体;mso-ascii-font-family:
"Times New Roman";mso-hansi-font-family:"Times New Roman"'>电缆管不应有穿孔,裂缝和显著的凹凸不平,内壁应光滑;金属电缆管不应有严重锈蚀。硬质塑料管不得用在温度过高或过低的场所。</span><span
lang=ZH-CN style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'> </span><span
style='mso-bidi-font-size:10.0pt'><o:p></o:p></span></p>
<p class=MsoNormal style='line-height:18.0pt;mso-layout-grid-align:none'><span
lang=ZH-CN style='font-family:宋体;mso-ascii-font-family:"Times New Roman";
mso-hansi-font-family:"Times New Roman"'>在易受机械损伤的地方和在受力较大处直埋时,应采用足够强度的管材。</span><span
lang=ZH-CN style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'> </span><span
style='mso-bidi-font-size:10.0pt'><o:p></o:p></span></p>
<p class=MsoNormal style='line-height:18.0pt;mso-layout-grid-align:none'><span
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'><span
style="mso-spacerun: yes"> </span></span><span lang=ZH-CN
style='font-family:宋体;mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:
"Times New Roman"'>第</span>3.0.2<span lang=ZH-CN style='font-family:宋体;
mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:"Times New Roman"'>条</span><span
lang=ZH-CN style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'> </span><span
lang=ZH-CN style='font-family:宋体;mso-ascii-font-family:"Times New Roman";
mso-hansi-font-family:"Times New Roman"'>电缆管的加工应符合下列要求:</span><span lang=ZH-CN
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'> </span><span
style='mso-bidi-font-size:10.0pt'><o:p></o:p></span></p>
<p class=MsoNormal style='line-height:18.0pt;mso-layout-grid-align:none'><span
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'><span
style="mso-spacerun: yes"> </span></span><span lang=ZH-CN
style='font-family:宋体;mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:
"Times New Roman"'>一、管口应无毛刺和尖锐棱角,管口宜做成喇叭形。</span><span lang=ZH-CN
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'> </span><span
style='mso-bidi-font-size:10.0pt'><o:p></o:p></span></p>
<p class=MsoNormal style='line-height:18.0pt;mso-layout-grid-align:none'><span
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'><span
style="mso-spacerun: yes"> </span></span><span lang=ZH-CN
style='font-family:宋体;mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:
"Times New Roman"'>二、电缆管在弯制后,不应有裂缝和显著的凹瘪现象,其弯扁程度不宜大于管子外径的</span>10%<span
lang=ZH-CN style='font-family:宋体;mso-ascii-font-family:"Times New Roman";
mso-hansi-font-family:"Times New Roman"'>;电缆管的弯曲半径不应小于所穿入电缆的最小允许弯曲半径。</span><span
lang=ZH-CN style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'> </span><span
style='mso-bidi-font-size:10.0pt'><o:p></o:p></span></p>
<p class=MsoNormal style='line-height:18.0pt;mso-layout-grid-align:none'><span
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'><span
style="mso-spacerun: yes"> </span></span><span lang=ZH-CN
style='font-family:宋体;mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:
"Times New Roman"'>三、金属电缆管应在外表涂防腐漆或涂沥青,镀锌管锌层剥落处也应涂以防腐漆。</span><span lang=ZH-CN
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'> </span><span
style='mso-bidi-font-size:10.0pt'><o:p></o:p></span></p>
<p class=MsoNormal style='line-height:18.0pt;mso-layout-grid-align:none'><span
style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'><span
style="mso-spacerun: yes"> </span></span><span lang=ZH-CN
style='font-family:宋体;mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:
"Times New Roman"'>第</span>3.0.3<span lang=ZH-CN style='font-family:宋体;
mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:"Times New Roman"'>条</span><span
lang=ZH-CN style='font-family:宋体;mso-hansi-font-family:"Times New Roman"'> </span><span