volts_vs_phase_angle.m
来自「电力系统书本的范例 想学好电力系统很有帮助 欢迎大家来下载」· M 代码 · 共 33 行
M
33 行
% M-file: volts_vs_phase_angle.m
% M-file to calculate the rms voltage applied to a load as
% a function of the phase angle firing circuit, and to
% plot the resulting relationship.
% Loop over all firing angles (1 to 179 degrees)
deg = zeros(1,179);
rms = zeros(1,179);
for ii = 1:179
% Save firing angle
deg(ii) = ii;
% First, generate the waveform to analyze.
waveform = zeros(1,180);
for jj = 1:180
waveform(jj) = ac_phase_controller(jj*pi/180,ii);
end
% Now calculate the rms voltage of the waveform
temp = sum(waveform.^2);
rms(ii) = sqrt(temp/180);
end
% Plot rms voltage of the load as a function of firing angle
plot(deg,rms,'LineWidth',2);
title('\bfLoad Voltage vs. Firing Angle');
xlabel('\bfFiring angle (deg)');
ylabel('\bfRMS voltage (V)');
grid on;