📄 medium_event.c
字号:
// (The actual limit is 0 as if volts too low just set
// brake chopper switch on time to zero.)
// The use of -10 prevents chatter as otherwise if volts
// even 1 LSB too low, the integral term is cleared.
if (voltage_error < -10)
{
voltage_integral=0;
return;
}
}
// Update Integral term here but this will be overwritten if
// found to be in limit later on in code
voltage_integral+=((long)voltage_error * (long)vloop_i_gain);
temp=voltage_integral+proportional_term;
// If sum of P+I terms pushes you into positive limit
if (temp > POS_V_LIMIT)
{
voltage_integral = POS_V_LIMIT - proportional_term;
return;
}
else
{
// If sum of P+I terms pushes you into negative limit
// It is OK to use 0 as the negative limit here as
// in steady state integral will be providing the
// control effort and even if get a few LSBs of negative
// error, voltage inegral is not cleared anyhow
if (temp <= 0)
{
// Now calculate integrator limit and clamp
voltage_integral = 0 - proportional_term;
return;
}
else
// Calculate control output based on both unclamped P and I terms
{
// Temp still contains unclamped P+I term so no need to recalculate
// Load up PR3 with the On time of the switch
PR3=(unsigned int)(temp/512);
TMR3=0;
// Set TIMER3 running so that when TMR3=PR3 switch turns off
IFS0bits.T3IF=0;
IEC0bits.T3IE=1;
}
}
return;
}
void starting_code(void)
{
unsigned int temp;
unsigned long ltemp;
static unsigned int rotation_timer=0;
// First of all check to see whether motor is already turning
// This is done by putting the system into acquire mode2
// and by monitoring a countdown timer called rotation timer
// If the system acquires it will automatically move to running
// sensorless. If the timer reaches zero before the system has
// acquired then the normal lock and ramp routine is entered
if (control_flags2.ROTATION_CHECK==TRUE)
{
DISABLE_INTERRUPTS;
control_flags.ACQUIRE2=TRUE;
control_flags.ADCCONFIG=TRUE;
control_flags2.ROTATION_CHECK=FALSE;
ENABLE_INTERRUPTS;
rotation_timer=user_parameters[36];
return;
}
if ((control_flags.ACQUIRE2==TRUE) && (rotation_timer))
{
rotation_timer--;
return;
}
else
{
control_flags.ACQUIRE2=FALSE;
}
// Now check for windmilling (going opposite direction
// to the demanded direction)
// If windmilling then all we do is run open loop
// decelerating motor with constant current demand
// until near zero speed and then revert to normal
// lock and ramp routine.
if (control_flags2.WINDMILLING==TRUE)
{
if (new_PR2 < BRAKING_PR2_LIMIT)
{
new_PR2+=windmilling_decel_rate;
return;
}
else
{
DISABLE_INTERRUPTS;
control_flags2.WINDMILLING=FALSE;
control_flags.DIR=user_parameters[0];
IEC0bits.T2IE=0;
control_flags.RAMP=FALSE;
control_flags.LOCK1=FALSE;
control_flags.LOCK2=FALSE;
ENABLE_INTERRUPTS;
}
}
// Are we in the ramping region of starting
if (control_flags.RAMP==TRUE)
{
// The following section of code is done in assembly so that
// can take advantage of the mul.us and div.sd instructions which
// the compiler does not use due to ANSI C compliance
// The calculations are:
// new_speed= ramp_start_speed + (ramp_speed_delta*(starting_timer/ramp_time)^2)
// temp = ramp_start_demand + (ramp_demand_delta*starting_timer/ramp_time)
// Note that the code is done within one asm instruction to ensure that
// the compiler does not insert instructions when optimizing
// First push w0-w5 onto the stack as the compiler may be using
// them to store intermediate results which are required later on
// in the C code. This will be especially true if optimization is used
#define V120 1
#ifdef ORIG
asm(" push.d w0");
asm(" push.d w2");
asm(" push.d w4");
asm(" mov.w _starting_timer,w1");
asm(" mov.w _starting_timer,w0");
asm(" mul.uu w0,w1,w4");
asm(" mov.w _ramp_time,w2");
asm(" repeat #17");
asm(" div.ud w4,w2");
asm(" mov.w _ramp_speed_delta,w1");
asm(" mul.uu w0,w1,w4");
asm(" repeat #17");
asm(" div.ud w4,w2");
asm(" mov.w _ramp_start_speed,w1");
asm(" add w0,w1,w0");
asm(" mov.w w0,_new_speed");
asm(" mov.w _ramp_demand_delta,w1");
asm(" mov.w _starting_timer,w0");
asm(" mul.us w0,w1,w4");
asm(" mov.w _ramp_time,w2");
asm(" repeat #17");
asm(" div.sd w4,w2");
asm(" mov.w w0,_stemp");
asm(" pop.d w4");
asm(" pop.d w2");
asm(" pop.d w0");
#elif V120
{ unsigned long mul_result;
register unsigned int div_result asm("w0");
/* asm("instruction(s)" : outputs : inputs :
clobbered registers ); */
asm volatile("mul.uu %1, %1, %0" : "=r"(mul_result) :
"r"(starting_timer));
asm volatile("repeat #17\n\t"
"div.ud %0, %1" : /* implied outputs */ : "r"(mul_result),
"r"(ramp_time) :
"w0", "w1" );
asm volatile("mul.uu %1, %2, %0":"=r"(mul_result) : "r"(div_result),
"r"(ramp_speed_delta));
asm volatile("repeat #17\n\t"
"div.ud %0, %1" : /* implied outputs */ : "r"(mul_result),
"r"(ramp_time) :
"w0", "w1" );
asm volatile("add %1, %2, %0" : "=r"(new_speed): "r"(ramp_start_speed),
"r"(div_result));
asm volatile("mul.us %1, %2, %0":"=r"(mul_result): "r"(starting_timer),
"r"(ramp_demand_delta));
asm volatile("repeat #17\n\t"
"div.ud %0, %1" : /* implied outputs */ : "r"(mul_result),
"r"(ramp_time) :
"w0", "w1" );
stemp = div_result;
}
#elif V130
{ unsigned long mul_result;
unsigned int div_result;
mul_result = __builtin_muluu(starting_timer, starting_timer);
div_result = __builtin_divud(mul_result, ramp_time);
mul_result = __builtin_muluu(div_result, ramp_speed_delta);
div_result = __builtin_divud(mul_result, ramp_time);
new_speed = div_result + ramp_start_speed;
mul_result =__builtin_mulus(starting_timer,ramp_demand_delta);
stemp = __builtin_divud(mul_result, ramp_time);
}
#else
#error Which version
#endif
temp=ramp_start_demand+stemp;
// temp contains the new demand value for current ramp position
// Now check to see if we are using voltage or current control
if (user_parameters[40])
{
// Compensate for inverted firing
temp=FULL_DUTY-temp;
// Disable updates of PWM duty registers to ensure
// All 3 values get loaded together
PWMCON2bits.UDIS=1;
PDC1=temp;
PDC2=temp;
PDC3=temp;
// Now enable updates
PWMCON2bits.UDIS=0;
}
else
current_demand=temp;
// Calculate new period value based on new_speed value
// number of motor poles and constants. Put it in ltemp
ltemp=(COUNTER_RATE*20) / \
((unsigned long)new_speed*(unsigned long)user_parameters[25]);
// Check that a period overflow has not occurred before
// actually writing the new value into new_PR2
if (ltemp>65535)
new_PR2=65535;
else
new_PR2=ltemp;
// Now check to see which acquistion method is being used
// If method 1 and the new step rate is < step rate where
// zero crossing is enabled, then go ahead and set flag
// so that zero crossings are checked during ramping.
if ((user_parameters[43]==FALSE) && \
(new_PR2<=acquire1_enable_rate) && \
(control_flags.ACQUIRE1==FALSE))
{
control_flags2.ACQUIRE1_REQUEST=TRUE;
acquire_counter=0;
}
// Now check to see if at end of ramp
if (new_PR2 <=ramp_end_rate)
{
// Must ensure interrupt does not occur here
// as otherwise can end up with ISR executing
// with some flags correct and some not.
// Also prefer to ensure all PWMs loaded up at
// at same time to avoid glitches
DISABLE_INTERRUPTS;
control_flags.RAMP=FALSE;
DISABLE_FIRING;
IEC0bits.T2IE = 0;
// Now check to see which acquisition method being used
// If using method 2 then set off acquire_position function
// by setting appropriate flags
if (user_parameters[43]==TRUE)
{
control_flags.ACQUIRE2=TRUE;
control_flags.ADCCONFIG=TRUE;
control_flags2.RETRY_FLAG=FALSE;
run_state=RUNNING;
}
else // using Method1 should have already acquired before
{ // end of ramp so enter fault condition
run_state=FAULT;
trip_state=FAILED_TO_START;
}
ENABLE_INTERRUPTS;
return;
}
}
// If both LOCK flags are false then this is the first time we have entered
// lock routines.
if ((control_flags.LOCK1==FALSE) && (control_flags.LOCK2==FALSE))
{
if (control_flags.RAMP==FALSE)
{
starting_timer=0;
control_flags.LOCK1=TRUE;
// Now check to see if we are using voltage or current control
if (user_parameters[40])
{
// Disable updates of PWM duty registers to ensure
// All 3 values get loaded together
PWMCON2bits.UDIS=1;
// Compensate for inverted firing as FULL_DUTY gives
// zero duty cycle.
PDC1=(FULL_DUTY-hold1_demand);
PDC2=PDC1;
PDC3=PDC1;
// Now enable updates
PWMCON2bits.UDIS=0;
}
else
current_demand=hold1_demand;
// This write to OVDCON will only allow 2 of the 6 inverter
// switches to actually fire so it does not matter that all
// three duty cycle values were loaded with the demand
OVDCON=SECTOR0_OVERRIDE;
// Now enable firing
ENABLE_FIRING;
}
}
// If at end of LOCK1 time
if ((starting_timer >= user_parameters[2]) \
&& (control_flags.LOCK1==TRUE))
{
starting_timer=0;
control_flags.LOCK1=FALSE;
control_flags.LOCK2=TRUE;
// If using voltage control for starting
if (user_parameters[40])
{
// Disable updates of PWM duty registers to ensure
// All 3 values get loaded together
PWMCON2bits.UDIS=1;
// Compensate for inverted firing as FULL_DUTY gives
// zero duty cycle.
// Note that event though all three duty cycles are the
// same, the write to OVDCON below will only allow the
// correct switches to actually fire.
PDC1=(FULL_DUTY-hold2_demand);
PDC2=PDC1;
PDC3=PDC1;
// Now enable updates
PWMCON2bits.UDIS=0;
}
else
current_demand=hold2_demand;
// Second energisation sector is direction dependent
if (control_flags.DIR==FORWARDS)
OVDCON=SECTOR1_OVERRIDE;
else
OVDCON=SECTOR5_OVERRIDE;
}
// If at end of LOCK2 time
if ((starting_timer > user_parameters[3]) \
&& (control_flags.LOCK2==TRUE))
{
control_flags.LOCK2=FALSE;
control_flags.RAMP=TRUE;
starting_timer=0;
// Now energise motor with maximum
// torque producive current which occurs
// two sectors ahead. As have moved 1 sector
// away from initial lock in correct direction
// of rotation, this is the same sector whichever
// direction we wish to rotate in.
// If using voltage control for starting
if (user_parameters[40])
{
// Disable updates of PWM duty registers to ensure
// All 3 values get loaded together
PWMCON2bits.UDIS=1;
// Compensate for inverted firing as FULL_DUTY gives
// zero duty cycle.
PDC1=(FULL_DUTY-ramp_start_demand);
PDC2=PDC1;
PDC3=PDC1;
// Now enable updates
PWMCON2bits.UDIS=0;
}
else
current_demand=ramp_start_demand;
// Now check to see which acquistion method is being used
// If method 1 and the initial ramp speed is > speed where
// zero crossing is enabled, then go ahead and set flag
// so that zero crossings are checked during ramping.
if ((user_parameters[43]==FALSE) && \
(ramp_start_rate<=acquire1_enable_rate))
{
control_flags2.ACQUIRE1_REQUEST=TRUE;
acquire_counter=0;
}
// Write to the sector variable so that commutation ISR
// will set up comutation correctly
sector=3;
// Load new_PR2 with initial step rate which will
// be loaded into PR2 almost immediately as forcing
// an interrupt of TMR2
new_PR2=ramp_start_rate;
IFS0bits.T2IF=TRUE;
IEC0bits.T2IE=TRUE;
}
starting_timer++;
return;
}