theta.f
来自「水文模型的原始代码」· F 代码 · 共 34 行
F
34 行
function theta(r20,thk,tmp)
!! ~ ~ ~ PURPOSE ~ ~ ~
!! this function corrects rate constants for temperature
!! Equation is III-52 from QUAL2E
!! ~ ~ ~ INCOMING VARIABLES ~ ~ ~
!! name |units |definition
!! ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~
!! r20 |1/day |value of the reaction rate coefficient at
!! |the standard temperature (20 degrees C)
!! thk |none |temperature adjustment factor (empirical
!! |constant for each reaction coefficient)
!! tmp |deg C |temperature on current day
!! ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~
!! ~ ~ ~ OUTGOING VARIABLES ~ ~ ~
!! name |units |definition
!! ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~
!! theta |1/day |value of the reaction rate coefficient at
!! |the local temperature
!! ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~
!! ~ ~ ~ ~ ~ ~ END SPECIFICATIONS ~ ~ ~ ~ ~ ~
real, intent (in) :: r20, thk, tmp
real :: theta
theta = 0.
theta = r20 * thk ** (tmp - 20.)
return
end