;* GSD-File for:	Danfoss Drives A/S																		*
;*							FCM 300 Series 12 Mb DPV1															*
;*																																*
;* File name:		da030408																						*
;*               																									*
;* Contact:			Danfoss Drives A/S																		*
;*							DK 6300 Graasten																			*
;*							Denmark																							*
;*							Hotline: Int. + 45 74 88 61 00													*
;*							E-mail: Drives_Hotline@danfoss.com											*
;*																																*
;* Revision:		da020408 Rev. 2.00 DPV0 file														*
;*							da030408 Rev. 3.00 DPV1 file														*
;*																																*
;*****************************************************************************
#Profibus_DP
GSD_Revision = 3;
Vendor_Name = "DANFOSS DRIVES A/S";
Model_name = "FCM 300 12MB";
Revision = "Rev. 3.00";
Ident_Number = 0x0408;
Protocol_Ident = 0;
Station_type = 0;
FMS_supp = 0;
Hardware_Release = "4.0";
Software_Release = "2.90";
Bitmap_Device = "FCM300"
Slave_Family = 1@Danfoss@FCM300@DPV1;
Info_Text = "FCM 300 PROFIBUS DPV1";
9.6_supp = 1;
19.2_supp = 1;
93.75_supp = 1;
187.5_supp = 1;
500_supp = 1;
1.5M_supp = 1;
3M_supp = 1;
6M_supp = 1;
12M_supp = 1;
MaxTsdr_9.6 = 15;
MaxTsdr_19.2 = 15;
MaxTsdr_93.75 = 15;
MaxTsdr_187.5 = 15;
MaxTsdr_500 = 15;
MaxTsdr_1.5M = 25;
MaxTsdr_3M = 50;
MaxTsdr_6M = 100;
MaxTsdr_12M = 200;
Redundancy = 0;
24V_Pins = 0;
Freeze_Mode_supp = 1;
Sync_Mode_supp = 1;
Auto_Baud_supp = 1;
Set_Slave_add_supp = 1;
Min_Slave_Intervall = 06;
Modular_Station = 1;
Max_Module = 1;
Max_Input_Len = 28;
Max_Output_Len = 28;
Max_Data_Len = 56;
Max_Diag_Data_Len = 32;
Fail_Safe = 1
;
;DPV1 specific
;
User_Prm_Data_Len = 3;
User_Prm_Data = 0x00,0x00,0x00
DPV1_Slave = 1
C1_Read_Write_supp = 1
C2_Read_Write_supp = 1
C1_Max_Data_Len = 240
C2_Max_Data_Len = 240
C1_Response_Timeout = 100
C2_Response_Timeout = 100
C1_Read_Write_required = 0  
C2_Read_Write_required = 0  
C2_Max_Count_Channels = 3
Max_Initiate_PDU_Length = 52
DPV1_Data_Types = 0
WD_Base_1ms_supp = 1
Check_Cfg_Mode = 0
Publisher_supp = 1
;
; Unit Diagnosis: Warning word par. 540. 
;
Unit_Diag_Bit(0)   = "Info text for FCM 300";
Unit_Diag_Bit(1)   = "Overflow SPM-FIFO";
Unit_Diag_Bit(2)   = "Actual value is not updated";
Unit_Diag_Bit(3)   = "Not used";
Unit_Diag_Bit(4)   = "Not used";
Unit_Diag_Bit(5)   = "Not used";
Unit_Diag_Bit(6)   = "Not used";
Unit_Diag_Bit(7)   = "See Manual for more information";

Unit_Diag_Bit(51)  = "[W Bit51]  HPFB bus timeout"
Unit_Diag_Bit(52)  = "[W Bit52]  Serial comm. timeout"
Unit_Diag_Bit(54)  = "[W Bit54]  Current limit"
Unit_Diag_Bit(55)  = "Not used"
Unit_Diag_Bit(40)  = "Not used"
Unit_Diag_Bit(41)  = "[W Bit41]  Inverter overload"
Unit_Diag_Bit(42)  = "Not used"
Unit_Diag_Bit(43)  = "Not used"
Unit_Diag_Bit(44)  = "[W Bit44]  Voltage warning low"
Unit_Diag_Bit(45)  = "[W Bit45]  Voltage warning high"
Unit_Diag_Bit(46)  = "[W Bit46]  Phase loss"
Unit_Diag_Bit(32)  = "[W Bit32]  Live zero error"
Unit_Diag_Bit(38)  = "[W Bit38]  Out of freq. range"
Unit_Diag_Bit(39)  = "[W Bit39]  Fieldbus com. fault"
Unit_Diag_Bit(30)  = "[W Bit30]  Switch mode warning"
Unit_Diag_Bit(31)  = "[W Bit31]  Heat sink temp. high"
;
; Unit Diagnosis: Extended Status word par. 541.  
;
Unit_Diag_Bit(80)  = "[S Bit80]  Ramping"
Unit_Diag_Bit(81)  = "Not used"
Unit_Diag_Bit(82)  = "[S Bit82]  Start clkw/anti-clkw"
Unit_Diag_Bit(83)  = "[S Bit83]  Slow down"
Unit_Diag_Bit(84)  = "[S Bit84]  Catch-up"
Unit_Diag_Bit(85)  = "Not used"
Unit_Diag_Bit(86)  = "Not used"
Unit_Diag_Bit(87)  = "Not used"
Unit_Diag_Bit(72)  = "Not used"
Unit_Diag_Bit(73)  = "Not used"
Unit_Diag_Bit(74)  = "Not used"
Unit_Diag_Bit(77)  = "Not used"
Unit_Diag_Bit(79)  = "[S Bit79]  Out of freq. range"
Unit_Diag_Bit(60)  = "[S Bit60]  PB acyclic MSAC1 com."
Unit_Diag_Bit(61)  = "[S Bit61]  PB acyclic MSAC2 com."
;
; Unit Diagnosis: Alarm word par. 538. 
;
Unit_Diag_Bit(113) = "[A Bit113] Trip locked"
Unit_Diag_Bit(114) = "Not used"
Unit_Diag_Bit(118) = "[A Bit118] HPFP bus timeout"
Unit_Diag_Bit(119) = "[A Bit119] Standard bus timeout"
Unit_Diag_Bit(104) = "[A Bit104] Short-circuiting"
Unit_Diag_Bit(105) = "[A Bit105] Switchmode fault"
Unit_Diag_Bit(106) = "[A Bit106] Earth fault"
Unit_Diag_Bit(107) = "[A Bit107] Overcurrent"
Unit_Diag_Bit(109) = "[A Bit109] Motor thermistor"
Unit_Diag_Bit(110) = "Not used"
Unit_Diag_Bit(111) = "[A Bit111] Inverter overload"
Unit_Diag_Bit(96)  = "[A Bit96]  Undervoltage"
Unit_Diag_Bit(97)  = "[A Bit97]  Overvoltage"
Unit_Diag_Bit(98)  = "[A Bit98]  Phase fault"
Unit_Diag_Bit(99)  = "[A Bit99]  Livezero error"
Unit_Diag_Bit(100) = "[A Bit100] Heat sink temp. high"
Unit_Diag_Bit(89)  = "[A Bit89]  Fieldbus com. fault"
Unit_Diag_Bit(91)  = "[A Bit91]  Inrush fault"
Unit_Diag_Bit(92)  = "[A Bit92]  Internal fault"
;
; Unit Diagnosis: Communication option warning word par. 953
;
Unit_Diag_Bit(128) = "Connection to master is not OK"
Unit_Diag_Bit(129) = "Not used"
Unit_Diag_Bit(130) = "FDL is not OK"
Unit_Diag_Bit(131) = "Clear data command received"
Unit_Diag_Bit(132) = "Actual value is not updated"
Unit_Diag_Bit(133) = "Spontaneous mes. FIFO overflow"
Unit_Diag_Bit(134) = "PROFIBUS ASIC is not transmit."
Unit_Diag_Bit(135) = "Init of PROFIBUS is not OK"
Unit_Diag_Bit(120) = "Not used"
Unit_Diag_Bit(121) = "Not used"
Unit_Diag_Bit(122) = "Not used"
Unit_Diag_Bit(123) = "Not used"
Unit_Diag_Bit(124) = "Error code during init: Bit 0"
Unit_Diag_Bit(125) = "Error code during init: Bit 1"
Unit_Diag_Bit(126) = "Error code during init: Bit 2"
Unit_Diag_Bit(127) = "Error code during init: Bit 3"
;
;Modules
;
Module = "PPO Typ 1 Module consistent PCD" 0xF3, 0xF1;
1
EndModule;
Module = "PPO Typ 1 Word consistent PCD  " 0xF3, 0x71;
2
EndModule;
Module = "PPO Typ 2 Module consistent PCD" 0xF3, 0xF5;
3
EndModule;
Module = "PPO Typ 2 Word consistent PCD  " 0xF3, 0x75;
4
EndModule;
Module = "PPO Typ 3 Module consistent PCD" 0xF1;
5
EndModule;
Module = "PPO Typ 3 Word consistent PCD  " 0x71;
6
EndModule;
Module = "PPO Typ 4 Module consistent PCD" 0xF5;
7
EndModule;
Module = "PPO Typ 4 Word consistent PCD  " 0x75;
8
EndModule;
Module = "PPO Typ 5 Module consistent PCD" 0xF3, 0xF9;
9
EndModule;
Module = "PPO Typ 5 Word consistent PCD  " 0xF3, 0x79;
10
EndModule;
Module = "PPO Typ 6 Module consistent PCD" 0xF3;
11
EndModule;
Module = "PPO Typ 6 Word consistent PCD  " 0x73;
12
EndModule;
Module = "PPO Typ 7 Module consistent PCD" 0xF7;
13
EndModule;
Module = "PPO Typ 7 Word consistent PCD  " 0x77;
14
EndModule;
Module = "PPO Typ 8 Module consistent PCD" 0xF9;
15
EndModule;
Module = "PPO Typ 8 Word consistent PCD  " 0x79;
16
EndModule;