#Profibus_DP
PrmText = 0
Text(0) = "Comms Timeout Time"
EndPrmText
ExtUserPrmData = 0 "Comms Timeout Time"
UNSIGNED8 10 0-100
Prm_Text_Ref = 0
EndExtUserPrmData
GSD_Revision = 2;
Vendor_Name = "AUCOM ELECTRONICS LTD";
Model_Name = "Soft Starter Profibus Module";
Revision = "1.5"
Ident_Number = 0x08A8
Protocol_Ident = 0 ;Specify profibus DP as protocol
Station_Type = 0 ;Specify profibus DP slave
FMS_supp = 0 ;Specify purely DP device
Hardware_Release = "2"
Software_Release = "1"
Bitmap_Device = "SSPM_N";
Bitmap_Diag = "SSPM_D";
Bitmap_SF = "SSPM_S";
Slave_Family = 2@Aucom@PROFIJAKE@JB;
9.6_supp = 1
19.2_supp = 1
45.45_supp = 1
93.75_supp = 1
187.5_supp = 1
500_supp = 1
1.5M_supp = 1
3M_supp = 1
6M_supp = 1
12M_supp = 1
;
MaxTsdr_9.6 = 60
MaxTsdr_19.2 = 60
MaxTsdr_45.45 = 60
MaxTsdr_93.75 = 60
MaxTsdr_187.5 = 60
MaxTsdr_500 = 100
MaxTsdr_1.5M = 150
MaxTsdr_3M = 250
MaxTsdr_6M = 450
MaxTsdr_12M = 800
;
Redundancy = 0
Repeater_Ctrl_Sig = 0
24V_Pins = 1 ;The 24V pin on D9 connector is an input.
Implementation_Type = "SPC3"
;
Freeze_Mode_supp = 1
Sync_Mode_supp = 1
Auto_Baud_supp = 1
Set_Slave_Add_supp = 0
Min_Slave_Intervall = 1
;
Modular_Station = 1
Max_Module = 1
Max_Input_Len = 12
Max_Output_Len = 12
Max_Data_Len = 24
Modul_Offset = 0
;
Fail_Safe = 0
Max_Diag_Data_Len = 13
Max_User_Prm_Data_Len = 24
;
Unit_Diag_Area = 0-7
Value(0) = "Shorted SCR"
Value(1)= "Excess Start Time"
Value(2)= "Overload A(Thermal model)"
Value(3)= "Motor Thermistor"
Value(4)= "Phase Loss/Imbalance"
Value(5)= "Invalid Frequency/Power loss"
Value(6) ="Incorrect Phase Sequence"
Value(7)= "Instantaneous Overcurrent"
Value(8)= "Power Circuit fault"
Value(9)= "Undercurrent"
Value(10)= "Starter Overtemperature (F)"
Value(11)= "Invalid Motor Connection (P)"
Value(12)= "Auxiliary Input A (J)"
Value(13)= "Out of Range FLC (L)"
Value(14)= "Incorrect Control Card (Y)"
Value(15)= "Comms Timeout fault (C)"
Value(16)= "Forced Comms trip (H)"
Value(17)= "Microprocessor/Control fault (U)"
Value(18)= "Overvoltage"
Value(19)= "Undervoltage"
Value(20)= "Ground fault"
Value(21)= "RTD Relay trip"
Value(22)= "RTD Comms failure"
Value(23)= "EEPROM failure"
Value(24)= "Auxiliary Input B"
Value(25)= "Bypass Contactor failure"
Value(26)= "L1 Phase Loss"
Value(27)= "L2 Phase Loss"
Value(28)= "L3 Phase Loss"
Value(29)= "L1 Shorted SCR"
Value(30)= "L2 Shorted SCR"
Value(31)= "L3 Shorted SCR"
Value(32)= "Overload B (Thermal Model)"
Value(33)= "Bypass Overload/Time Overcurrent"
Value(34)= "SCR Temperature Model"
Value(35)= "Battery/Clock"
Value(255)= "No Trip"
Unit_Diag_Area_End
;
Module = "Basic" 0xD0,0x60
1
Ext_Module_Prm_Data_Len = 1
Ext_User_Prm_Data_Ref(0) = 0
EndModule
Module = "Extended" 0xD0,0x60,0xD1,0x20
2
Ext_Module_Prm_Data_Len = 1
Ext_User_Prm_Data_Ref(0) = 0
EndModule
Module = "Extended + Starter Parameters" 0xD0,0x60,0xD1,0x20,0xD1,0x61
3
Ext_Module_Prm_Data_Len = 1
Ext_User_Prm_Data_Ref(0) = 0
EndModule
;