📄 lmp_blst.c

📁 IT projecotr reference design.
💻 C
📖 第 1 页 / 共 3 页
字号:
    error = URT_Write (LMP_BLST_PortNum, 2, &write_buffer[0], LMP_BLST_UART_DELAY, &numBytesWritten);

    if (error == PASS)
    {
        /* Check response for "Waveform Programming Mailbox" command */
        error = URT_Read  (LMP_BLST_PortNum, 2, &read_buffer[0],  LMP_BLST_UART_DELAY, &numBytesRead);

        if (error == PASS)
        {
            if (read_buffer[0] == 0x73)
            {
                if ((LMP_BLST_CurrERR != LMP_BLST_NOSEQMATCH) && (LMP_BLST_CurrERR != LMP_BLST_WAVEFORM_OOR))
                    LMP_BLST_SetLampStatus (FALSE, PASS);
            }
            else
            {
                error = LMP_BLST_BALLASTERR;
                LMP_BLST_SetLampStatus (TRUE, error);
            }
        }
        else
        {
            if (error == URT_TIMEOUT)
                error = LMP_BLST_TIMEOUT;
            else
                error = LMP_BLST_URTERR;

            LMP_BLST_SetLampStatus (TRUE, error);
        }
    }
    else
    {
        if (error == URT_TIMEOUT)
            error = LMP_BLST_TIMEOUT;
        else
            error = LMP_BLST_URTERR;

        LMP_BLST_SetLampStatus (TRUE, error);
    }
    
    RTA_SemRelease(LMP_BLST_Sem);

    return error;
}


/****************************************************************************/
/* This function reads the mailbox with address startingat the StartAddr    */
/* with LMP_BLST_OpenMailBox API call, consecutive call to                  */
/* LMP_BLST_ReadMailBox API will cause the next byte to be read.            */
/*                                                                          */
/*  param  Data - O - Data read from the mailbox                            */
/*                                                                          */
/*  return PASS = Successful                                                */
/*         FAIL = Unsuccessful                                              */
/*         LMP_BLST_INUSEERR     = Lamp UART is in use                      */
/*         LMP_BLST_TIMEOUT      = UART Timeout                             */
/*         LMP_BLST_URTERR       = UART all other Errors                    */
/*         LMP_BLST_BALLASTERR   = Ballast returned error                   */
/****************************************************************************/

int08  LMP_BLST_ReadMailBox (uint08 *Data)
{
    int08   error = FAIL;

    if(RTA_SemReserve(LMP_BLST_Sem, TMR_ConvertMSToTicks(LMP_BLST_SEM_DELAY)) != RTA_SUCCESS)
        return LMP_BLST_INUSEERR;

    URT_FlushReadFIFO(LMP_BLST_PortNum); /* Discard any spurious data */

    /* Read Byte Mailbox */
    write_buffer[0] = 0xF9;
    error = URT_Write (LMP_BLST_PortNum, 1, &write_buffer[0], LMP_BLST_UART_DELAY, &numBytesWritten);

    if (error == PASS)
    {
        /* Check response for "Read Byte Mailbox" command */
        error = URT_Read  (LMP_BLST_PortNum, 2, &read_buffer[0],  LMP_BLST_UART_DELAY, &numBytesRead);

        if (error == PASS)
        {
            if (read_buffer[0] == 0xF9)
            {
                if ((LMP_BLST_CurrERR != LMP_BLST_NOSEQMATCH) && (LMP_BLST_CurrERR != LMP_BLST_WAVEFORM_OOR))
                    LMP_BLST_SetLampStatus (FALSE, PASS);

                *Data  = read_buffer[1];
            }
            else
            {
                error = LMP_BLST_BALLASTERR;
                LMP_BLST_SetLampStatus (TRUE, error);
            }
        }
        else
        {
            if (error == URT_TIMEOUT)
                error = LMP_BLST_TIMEOUT;
            else
                error = LMP_BLST_URTERR;

            LMP_BLST_SetLampStatus (TRUE, error);
        }
    }
    else
    {
        if (error == URT_TIMEOUT)
            error = LMP_BLST_TIMEOUT;
        else
            error = LMP_BLST_URTERR;

        LMP_BLST_SetLampStatus (TRUE, error);
    }

    RTA_SemRelease(LMP_BLST_Sem);

    return error;
}


/****************************************************************************/
/* This function closes the mailbox.                                        */
/*                                                                          */
/*  return PASS = Successful                                                */
/*         FAIL = Unsuccessful                                              */
/*         LMP_BLST_INUSEERR     = Lamp UART is in use                      */
/*         LMP_BLST_TIMEOUT      = UART Timeout                             */
/*         LMP_BLST_URTERR       = UART all other Errors                    */
/*         LMP_BLST_BALLASTERR   = Ballast returned error                   */
/****************************************************************************/

int08  LMP_BLST_CloseMailBox (void)
{
    int08   error = FAIL;

    if(RTA_SemReserve(LMP_BLST_Sem, TMR_ConvertMSToTicks(LMP_BLST_SEM_DELAY)) != RTA_SUCCESS)
        return LMP_BLST_INUSEERR;

    URT_FlushReadFIFO(LMP_BLST_PortNum); /* Discard any spurious data */

    /* Waveform Mailbox Control */
    write_buffer[0] = 0x74;
    write_buffer[1] = 0x00;     /* clear up the address fields */
    write_buffer[2] = 0x00;
    write_buffer[3] = FALSE;    /* disable access */
    error = URT_Write (LMP_BLST_PortNum, 4, &write_buffer[0], LMP_BLST_UART_DELAY, &numBytesWritten);
    error = URT_Read  (LMP_BLST_PortNum, 4, &read_buffer[0],  LMP_BLST_UART_DELAY, &numBytesRead);

    if (read_buffer[0] == 0x74)
    {
        if ((LMP_BLST_CurrERR != LMP_BLST_NOSEQMATCH) && (LMP_BLST_CurrERR != LMP_BLST_WAVEFORM_OOR))
            LMP_BLST_SetLampStatus (FALSE, PASS);
    }
    else
    {
        error = LMP_BLST_BALLASTERR;
        LMP_BLST_SetLampStatus (TRUE, error);
    }

    RTA_SemRelease(LMP_BLST_Sem);
                           
    return error;
}


/****************************************************************************/
/* This function returns the mailbox status.                                */
/*                                                                          */
/*  param  StartAddr - O - Current address of the mailbox.                  */
/*         MailboxAccess - O - TRUE - Write enabled. FALSE - Write Disabled.*/
/*                                                                          */
/*                                                                          */
/*  return PASS = Successful                                                */
/*         FAIL = Unsuccessful                                              */
/*         LMP_BLST_INUSEERR     = Lamp UART is in use                      */
/*         LMP_BLST_TIMEOUT      = UART Timeout                             */
/*         LMP_BLST_URTERR       = UART all other Errors                    */
/*         LMP_BLST_BALLASTERR   = Ballast returned error                   */
/****************************************************************************/

int08  LMP_BLST_GetMailboxStatus (uint16 *StartAddr, uint08 *MailboxAccess)
{
    int08   error = FAIL;

    if(RTA_SemReserve(LMP_BLST_Sem, TMR_ConvertMSToTicks(LMP_BLST_SEM_DELAY)) != RTA_SUCCESS)
        return LMP_BLST_INUSEERR;

    URT_FlushReadFIFO(LMP_BLST_PortNum); /* Discard any spurious data */

    /* Mailbox Status Readback */
    write_buffer[0] = 0xF7;
    error = URT_Write (LMP_BLST_PortNum, 1, &write_buffer[0], LMP_BLST_UART_DELAY, &numBytesWritten);
    error = URT_Read  (LMP_BLST_PortNum, 4, &read_buffer[0],  LMP_BLST_UART_DELAY, &numBytesRead);    /* echo + address bytes + control byte */
    /* Philips ballast only returns the echo + two bytes of address */
    /* Currently this logic won't work with Philips' ballast */
    if (read_buffer[0] == 0xF7)
    {
        *StartAddr     = ((read_buffer[1] << 8) | read_buffer[2]);
        *MailboxAccess = read_buffer[3];
    }
    else
    {
        error = LMP_BLST_BALLASTERR;
        LMP_BLST_SetLampStatus (TRUE, error);
    }

    RTA_SemRelease(LMP_BLST_Sem);
    
    return error;
}


/****************************************************************************/
/* This function returns the Ballast Manufacturer ID.                       */
/*                                                                          */
/*  return Ballast Manufacture ID.                                          */
/****************************************************************************/

uint08 LMP_BLST_GetManufacturerID (void)
{
    return LMP_BLST_BallastMfgID;
}


/****************************************************************************/
/* This function returns the hardware and software Ballast IDs.             */
/* Byte 1 is the hardware ID and byte 2 is the software ID.                 */
/*                                                                          */
/*  return Ballast ID.                                                      */
/****************************************************************************/

uint16 LMP_BLST_GetBallastID (void)
{
    return LMP_BLST_BallastID;
}


/****************************************************************************/
/* This function returns the current ballast status.                        */
/* -------------------------------------------------------------            */
/* |    Reserved for future status   | Reserved | Lamp On |                 */
/* -------------------------------------------------------------            */
/* -------- bit7 through bit2 -------- bit1 ------- bit0 ---                */
/*                                                                          */
/*  param  BallastStatus - O - Ballast status                               */
/*                                                                          */
/*  return PASS = Successful                                                */
/*         FAIL = Unsuccessful                                              */
/*         LMP_BLST_INUSEERR     = Lamp UART is in use                      */
/*         LMP_BLST_TIMEOUT      = UART Timeout                             */
/*         LMP_BLST_URTERR       = UART all other Errors                    */
/*         LMP_BLST_BALLASTERR   = Ballast returned error                   */
/****************************************************************************/

int08 LMP_BLST_GetBallastStatus (uint08 *BallastStatus)
{
    int08   error = FAIL;

    LMP_BLST_CurrLmpLit = FALSE;
    
    if(RTA_SemReserve(LMP_BLST_Sem, TMR_ConvertMSToTicks(LMP_BLST_SEM_DELAY)) != RTA_SUCCESS)
        return LMP_BLST_INUSEERR;

    URT_FlushReadFIFO(LMP_BLST_PortNum); /* Discard any spurious data */

    /* Ballast Status */
    write_buffer[0] = 0xF5;
    error = URT_FlushFIFOs   (LMP_BLST_PortNum);
    error = URT_Write (LMP_BLST_PortNum, 1, &write_buffer[0], LMP_BLST_UART_DELAY, &numBytesWritten);
    error = URT_Read  (LMP_BLST_PortNum, 2, &read_buffer[0],  LMP_BLST_UART_DELAY, &numBytesRead);

    if (error == PASS)
    {
        if (read_buffer[0] == 0xF5)
        {
            *BallastStatus      = read_buffer[1];
            LMP_BLST_CurrLmpLit = ((*BallastStatus & LMP_BLST_LAMPON) != 0);
        }
        else
            error = LMP_BLST_BALLASTERR;
    }
    else
    {
        if (error == URT_TIMEOUT)
            error = LMP_BLST_TIMEOUT;
        else
            error = LMP_BLST_URTERR;
    }

    RTA_SemRelease(LMP_BLST_Sem);
    
    return error;
}


/****************************************************************************/
/* This function sets the Lamp Status.                                      */
/* which includes the flag whether in the lamp sync off safe mode and       */
/* the err code that cause the lamp error (see LMP_BLST.h for return codes) */
/*                                                                          */
/*  param  LampSafeMode - I - TRUE/FALSE to set lamp in safe mode           */
/*         LampERRCode  - I - error code that cause the lamp error and      */
/*                            switch to safe mode; LMP_BLST_NOSEQMATCH,     */
/*                            LMP_BLST_WAVEFORM_OOR, or LMP_BLST_TIMEOUT    */
/*                                                                          */
/*  return PASS                                                             */
/****************************************************************************/

int08 LMP_BLST_SetLampStatus (BOOL LampSafeMode, int08 LampERRCode)
{
    /* save the safe mode flag and error code */
    LMP_BLST_SafeMode = LampSafeMode;
    LMP_BLST_CurrERR  = LampERRCode;
    
    if (LMP_BLST_CurrERR == PASS)
    {
        // if UART lamp OKAY, then enable lamp sync
        LMP_SetLampSyncType( gpConfiguration->Illum.LampSyncType, FALSE, TRUE );
    }
    else
    {
        // if UART Lamp error occurred (OOR or no match), then disable lamp sync
        LMP_SetLampSyncType(LMP_SYNC_OFF, 0, 0);
    }
    
    return PASS;
}


/****************************************************************************/
/* This function returns the current Lamp Status, which includes byte for   */
/* UART is in "SAFE" mode and UART Mode Error code (see LMP_BLST.h for      */
/* return codes).                                                           */
/*                                                                          */
/*  param  LampSafeMode - O - TRUE - Lamp is in safe mode. FALSE - Lamp is  */
/*                                   in normal mode.                        */
/*                                                                          */
/*  param  LampERRCode  - O - Error code that cause the lamp error and      */
/*                            switch to safe mode                           */
/*                                                                          */
/*  return PASS.                                                            */
/****************************************************************************/

int08 LMP_BLST_GetLampStatus (BOOL *LampSafeMode, int08 *LampERRCode)
{
    *LampSafeMode = LMP_BLST_SafeMode;
    *LampERRCode  = LMP_BLST_CurrERR;
    return PASS;
}

⌨️ 快捷键说明