⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rf_command_handler.html

📁 PKE(被动无钥门禁系统
💻 HTML
字号:
<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN" "http://www.w3.org/TR/html4/loose.dtd">
<!--NewPage-->
<HTML>
<HEAD>
<!-- Generated by AsmDoc -->
<TITLE>
HTMLWriter
</TITLE>

<META NAME="keywords" CONTENT="HTMLWriter class">

<LINK REL ="stylesheet" TYPE="text/css" HREF="stylesheet.css" TITLE="Style">

<SCRIPT type="text/javascript">
function windowTitle()
{
    parent.document.title="RF_COMMAND_HANDLER";
}
</SCRIPT>
<NOSCRIPT>
</NOSCRIPT>

</HEAD>

<BODY BGCOLOR="white" onload="windowTitle();">


<!-- ======== START OF CLASS DATA ======== -->
<H2>
Module RF_COMMAND_HANDLER</H2>
<HR>

<P>
	This module implements the systems reaction to an incoming RF-Command.	Incoming RF-Data, which has been requested for example by a LF-Command	will not be handled in this module.
<P>

<P>
<HR>

<P>
<!-- ========== METHOD SUMMARY =========== -->

<A NAME="method_summary"><!-- --></A>
<TABLE BORDER="1" WIDTH="100%" CELLPADDING="3" CELLSPACING="0" SUMMARY="">
<TR BGCOLOR="#CCCCFF" CLASS="TableHeadingColor">
<TH ALIGN="left" COLSPAN="2"><FONT SIZE="+2">
<B>Function Summary</B></FONT></TH>
</TR>
<TR BGCOLOR="white" CLASS="TableRowColor">
<TD ALIGN="right" VALIGN="top" WIDTH="1%"><FONT SIZE="-1">
<CODE></CODE></FONT></TD>
<TD><CODE><B><A HREF="RF_COMMAND_HANDLER.html#RF_COMMAND_HANDLER">RF_COMMAND_HANDLER</A></B>()</CODE>

<BR>
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;	This function is being called whenever the RF-Line goes high, and the event is enabled.</TD>
</TR>
</TABLE>
&nbsp;
<P>

<!-- ============ METHOD DETAIL ========== -->

<A NAME="method_detail"><!-- --></A>
<TABLE BORDER="1" WIDTH="100%" CELLPADDING="3" CELLSPACING="0" SUMMARY="">
<TR BGCOLOR="#CCCCFF" CLASS="TableHeadingColor">
<TH ALIGN="left" COLSPAN="1"><FONT SIZE="+2">
<B>Method Detail</B></FONT></TH>
</TR>
</TABLE>

<A NAME="RF_COMMAND_HANDLER"></A><H3>
RF_COMMAND_HANDLER</H3>
<PRE>
&nbsp;<B>RF_COMMAND_HANDLER</B>()</PRE>
<P>
<DL>
<DD>	This function is being called whenever the RF-Line goes high, and the event is enabled.	So, when requesting data from a module this event should be disabled (bcf INTCON,RBIE).
<P>
<P>
<DD><DL>
<DT><B>Used SFRs:</B><DD>T0CON INTCON ,T0IE FSR2                                TMR0L                                                   </DD></DL>
</DD>
<DD><DL>
<DT><B>Calls subroutines:</B><PRE>	RF_RX.ReceiveStream		RF_RX.WaitResponse			RF_RX.DetectEdge			Delay.Mikros				Delay.Start8				Delay.Start16		RF_RX.ReceiveHeader			RF_RX.DetectEdge			Delay.Mikros				Delay.Start8				Delay.Start16		RF_RX.ReceiveByte	String.ReadPGM2RAM		String.Hex2ASCII	String.Hex2ASCII	LCD.DrawBuffer		LCD.Clear			LCD.SendCMD				LCD.BUSY_CHECK		LCD.SetLine0			LCD.SendCMD				LCD.BUSY_CHECK		LCD.DrawString			LCD.DrawChar				LCD.BUSY_CHECK		LCD.SetLine1			LCD.SendCMD				LCD.BUSY_CHECK
</PRE>
</DD></DL>
<DD><DL>
<DT><B>Stacklevel:</B><DD>5</DD></DL>
</DD>
<DD><DL>
<DT><B>Status:</B><DD> Tested</DD></DL>
</DD>
</DL>
<HR>
&nbsp;
<!-- ========= END OF CLASS DATA ========= -->




</BODY>
</HTML>

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -