working as fast as it can to receive packets and pass them up to 

the OS. In doing so it will hog CPU time and the OS may drop packets

due to lack of an ability to process them. It has been found that

during these heavy traffic conditions, throughput can be significantly

improved if the driver voluntarily releases the CPU. Yes, this will

cause more packets to be dropped on the wire but a greater number

of packets are spared because the OS has more time to process them.



As of version 1.05 and later, the driver implements a new flow control

detection method that operates like this. If the driver detects an

excessive work load in the period of 100mS, then the driver

assumes there is insufficient flow control in use. Therefor it will 

turn on driver level flow control. Which significantly reduces the 

amount of time the driver holds the CPU, and causes more packets to

be dropped on the wire. So a balancing/tuning, needs to be performed

on each system to get the best performance under these conditions. 

If however the driver detects a tolerable work load in a period of 

100mS then it assumes flow control is being managed well and does 

not attempt to intervene by releasing the CPU. Under these conditions

the driver will naturally release the CPU to the OS, since the system

as a whole is keeping up with traffic.



Now that the background has been discussed, its necessary to talk 

about how the driver implements flow control. The method used is a 

work load model. This is similar but not exactly the same as 

throughput. Work load is the sum of all the packet sizes plus a constant

packet cost for each packet. This provides more balance. For instance

a stream of max size packets will give a large throughput with fewer

packets, while a stream of min size packets will give a low throughput

with many packets. Adding a per packet cost to the work load allows these

two cases to both activate and manage flow control. If work load only 

counted packet sizes then only a stream of max size packets would

activate flow control, while a stream of min size packets would not.



There are five primary parameters responsible for managing flow control.

They can be found in the FLOW_CONTROL_PARAMETERS structure. 

They are

	MaxThroughput, Represents the maximum throughput measured in a 

		100mS period, during an rx TCP_STREAM test.		

	MaxPacketCount, Represents the maximum packet count measured in a 

		100mS period, during an rx TCP_STREAM test.

	PacketCost, Represents the optimal per packet cost

	BurstPeriod, Represents the optimal burst period in 100uS units.

	IntDeas, This is the value for the interrupt deassertion period.

	    It is set to INT_DEAS field of the INT_CFG register.

The driver will call Platform_GetFlowControlParameters to get these



parameters for the specific platform and current configuration.

These parameters must be carefully choosen by the driver writer so

optimal performance can be achieved. Therefor it is necessary to 

describe how the driver uses each parameter.



The first three parameters MaxThroughput, MaxPacketCount, and PacketCost,

are used to calculate the secondary parameter, MaxWorkLoad according

to the following formula.

	MaxWorkLoad=MaxThroughput+(MaxPacketCount*PacketCost);

MaxWorkLoad represents the maximum work load the system can handle during

a 100mS period.

	The driver will use MaxWorkLoad and BurstPeriod to determine 

BurstPeriodMaxWorkLoad, which represents the maximum amount of work the 

system can handle during a single burst period. It is calculated as follows

	BurstPeriodMaxWorkLoad=(MaxWorkLoad*BurstPeriod)/1000;



Every 100mS the driver measures the CurrentWorkLoad by the following 

algorithm.



	At the beginning of a 100mS period

		CurrentWorkLoad=0;

		

	During a 100mS period CurrentWorkLoad is adjusted when a packet

	arrives according to the following formula.

		CurrentWorkLoad+=PacketSize+PacketCost;

		

	At the end of a 100mS period

		if(CurrentWorkLoad>((MaxWorkLoad*(100+ActivationMargin))/100)) 

		{

			if(!FlowControlActive) {

				FlowControlActive=TRUE;

				//Do other flow control initialization

				BurstPeriodCurrentWorkLoad=0;

			}

		}

		if(CurrentWorkLoad<((MaxWorkLoad*(100-DeactivationMargin))/100))

		{

			if(FlowControlActive) {

				FlowControlActive=FALSE;

				//Do other flow control clean up

				Enable Receiver interrupts

			}

		}



During periods where flow control is active, that is 

FlowControlActive==TRUE, the driver will manage flow control by the

following algorithm.



	At the end/beginning of a burst period

		if(BurstPeriodCurrentWorkLoad>BurstPeriodMaxWorkLoad) {

			BurstPeriodCurrentWorkLoad-=BurstPeriodMaxWorkLoad;

		} else {

			BurstPeriodCurrentWorkLoad=0;

		}

		Enable Receiver Interrupts;

		

	When checking if a packet arrives

		if(BurstPeriodCurrentWorkLoad<BurstPeriodMaxWorkLoad) {

			//check for packet normally

			BurstPeriodCurrentWorkLoad+=PacketSize+PacketCost;

		} else {

			//Do not check for packet, but rather

			//  behave as though there is no new packet.

			Disable Receiver interrupts

		}



This algorithm will allow the driver to do a specified amount

of work and then give up the CPU until the next burst period. Doing this

allows the OS to process all the packets that have been sent to it.



So that is generally how the driver manages flow control. For more

detail you can refer to the source code. Now it is necessary to 

describe the exact method for obtaining the optimal flow control 

parameters.



When obtaining the optimal flow control parameters it is important

to note the configuration you are using. Generally there are 8

configurations for each platform. They involve the following options

	DMA or PIO

	16 bit or 32 bit

	118/117/112 or 116/115

Some platforms may only use 16 bit mode. While other platforms may 

have a selectable clock rate. What ever the options are, every combination

should be identifiable, and Platform_GetFlowControlParameters should be

implemented to provide the correct flow control parameters. It is important

to be sure that the carefully selected parameters are applied to the

same configuration used during tuning.



Flow control tuning requires a publically available program called

netperf, and netserver, which are a client/server pair. These are built 

with the same make file and can be found on the web.



Fortunately, as of version 1.10, smsc9118 and cmd9118 supports an automated

tuning mechanism. The process takes about one hour and can be initiated as

follows



AUTOMATED TUNING:



Choose the configuration you want to tune. 

That is choose between

  DMA or PIO,

  16 bit or 32 bit,

  118/117/112 or 116/115,

Make sure there is a direct connection between the target platform

and the host platform. Do not use a hub, or switch. The target

platform is the platform that will run this driver. The host platform

should be a PC easily capable of sending wire speed traffic.



Install the driver on your target platform with your choosen configuration.

	insmod smsc9118d.o 

	ifconfig eth1 192.1.1.118

load servers on target platform

	netserver

	cmd9118 -cSERVER

On host platform, make sure the netperf executable is 

located in the same directory and the cmd9118 executable. While in that

directory run the following.

	cmd9118 -cTUNER -H192.1.1.118

This command, if successful, will begin the one hour tuning process.

At the end you will get a dump of the optimal flow control parameters.

The key parameters needed are

    MaxThroughput

    MaxPacketCount

    PacketCost

    BurstPeriod

    IntDeas

These value must be assigned in Platform_GetFlowControlParameters to

	flowControlParameters->MaxThroughput

	flowControlParameters->MaxPacketCount

	flowControlParameters->PacketCost

	flowControlParameters->BurstPeriod

	flowControlParameters->IntDeas

Make sure the Platform_GetFlowControlParameters checks the current configuration

and will only set those parameters if the current configuration matches the

configuration you tuned with.



Next start over but choose a configuration you haven't already tuned.

   



MANUAL TUNING:

In the off chance that the automated tuning fails to work properly, you may

use the following manual tuning procedure.



STEP 1:

	Select a configuration. That is choose between DMA or PIO, 16 bit or 

	32 bit, 118/117/112 or 116/115.

	Make sure there is a direct connection between the target platform

	and the host platform. Do not use a hub, or switch. The target

	platform is the platform that will run this driver. The host platform

	should be a PC easily capable of sending wire speed traffic.



STEP 2:

	load the driver on the target platform with the following commands

		insmod smsc9118.o max_work_load=0 int_deas=ID

		ifconfig eth1 192.1.1.118

		netserver

	ID will be replated by the number you will be adjusting to obtain the

		best throughput score in STEP 3, initially a goog number to start

		with is 0.



STEP 3:

	On  the host platform run the following command

		netperf -H192.1.1.118 

	Examine the output. The goal is to maximize the number on the 

		Throughput column.

	If you are satisfied with the throughput remember the ID number

		you used and move on to STEP 4.

	If you would like to try improving the throughput

		unload the driver on the target with

			ifconfig eth1 down

			rmmod smsc9118

		goto STEP 2 and use a different value for ID



	

STEP 4:

	unload the driver with 

		ifconfig eth1 down

		rmmod smsc9118

	load driver on the target platform with the following commands

		insmod smsc9118.o max_work_load=0 int_deas=ID

		ifconfig eth1 192.1.1.118

		netserver

	NOTE: the driver will be making traffic measurements. Therefor

		it is important not to insert any steps between 4 and 6.

		

STEP 5:	

	run netperf on the host platform

		netperf -H192.1.1.118

	repeat two more times.

	

STEP 6:

	on target platform run the following

		cmd9118 -cGET_FLOW

	Many variables will be displayed. Two of them are measurements we need.

	You can set the following two parameters as follows.

		MaxThroughput  = RxFlowMeasuredMaxThroughput;

		MaxPacketCount = RxFlowMeasuredMaxPacketCount;

		

STEP 7:

	Unload the driver on target platform with

		ifconfig eth1 down

		rmmod smsc9118

	Apply the parameters obtained in STEP 6 and 2/3 to the appropriate location,

		given the configuration choosen in STEP 1, in

		Platform_GetFlowControlParameters. The parameters for your

		choosen configuration should be set as follows

			MaxThroughput = (RxFlowMeasuredMaxThroughput from step 6);

			MaxPacketCount = (RxFlowMeasuredMaxPacketCount from step 6);

			PacketCost=0; //temporarily set to 0

			BurstPeriod=100; //temporarily set to 100

			IntDeas= (ID from step 2/3).

	recompile driver.

		

STEP 8:

	Again make sure your still using the same configuration you selected

		in STEP 1.

	Load recompiled driver on target platform with the following commands

		insmod smsc9118.o burst_period=BP

		ifconfig eth1 192.1.1.118

	BP will be replaced by the number you will be adjusting to obtain the

		best throughput score in STEP 9, initially a good number to 

		start with is 100.



STEP 9:

	On Host platform run the following command

		netperf -H192.1.1.118 -tUDP_STREAM -l10 -- -m1472

	Examine the output.	The goal is to maximize the lower 

		number on the Throughput column.

	If you are satisfied with the throughput remember the BP number 

		you used and move on to STEP 10.

	If you would like to try improving the throughput

		unload the driver on the target with

			ifconfig eth1 down

			rmmod smsc9118

		goto STEP 8 and use a different value for BP.

		

STEP 10:

	unload the driver on target platform

		ifconfig eth1 192.1.1.118 down

		rmmod smsc9118

	Again make sure your still using the same configuration you selected

		in STEP 1.

	Load the recompiled driver from STEP 7 on target platform with 

		insmod smsc9118.o burst_period=BP packet_cost=PC

		ifconfig eth1 192.1.1.118

	BP will be replaced with the value you settled on in STEP 8/9.

	PC will be replaced by the number you will be adjusting to 

		obtain the best throughput score in STEP 11, typically PC ends 

		up somewhere between 100 and 200.



STEP 11:

	On Host platform run the following command

		netperf -H192.1.1.118 -tUDP_STREAM -l10 -- -m16

	Examine the output. The goal is to maximize the lower

		number on the Throughput column.

	If you are satisfied with the throughput remember the PC number

		you used and move on the STEP 12.

	If you would like to try improving the throughput