📄 pointdirbak.cfg
字号:
BEGIN_HEAD
VERSION OF CONFIGER 2.0
PROJECT 红雁池#1机组XDPS系统
ON 2003年4月24日
AT 11:28:35
END_HEAD
BEGIN_AX
3,200,PIA-101,1#蒸汽总管压力,TBL,MPa,7.2, 0, 0
3,200,PIC-102,2#蒸汽总管压力,TBL,MPa,7.2, 0, 0
3,200,PI-103,3#蒸汽总管压力,JTB,MPa,7.2, 0, 0
3,200,PR-109,1#蒸发锅压力,JT,MPa,7.2, 0, 0
3,200,PR-111,2#蒸发锅压力,JT,MPa,7.2, 0, 0
3,200,PR-113,3#蒸发锅压力,JT,MPa,7.2, 0, 0
3,200,PIA-115,1#汽包压力,JT,MPa,7.2, 0, 0
3,200,PIA-117,2#汽包压力,JT,MPa,7.2, 0, 0
3,200,PIA-119,3#汽包压力,BL,MPa,7.2, 0, 0
3,200,PI-129,二塔泵出口压力,BL,MPa,7.2, 0, 0
3,200,PI-130,二塔泵出口压力,DCS,MPa,7.2, 0, 0
3,200,PI-140,空气缓冲罐压力,DCS,MPa,7.2, 0, 0
3,200,PI-141,空气缓冲罐压力,L,MPa,7.2, 0, 0
3,200,PI-142,空气缓冲罐压力,BL,MPa,7.2, 0, 0
3,200,PRC-202,醛塔塔釜压力,BL,MPa,7.2, 0, 0
3,200,PRC-203,醛塔塔顶压力,JTB,MPa,7.2, 0, 0
3,200,PI-218,酒塔塔顶压力,JT,MPa,7.2, 0, 0
3,200,PRC-219,酒塔塔釜压力,JTB,MPa,7.2, 0, 0
3,200,PICA-304,空气缓冲罐压力,JT,MPa,7.2, 0, 0
3,200,PICA-313,氧化塔顶压力,B,MPa,7.2, 0, 0
3,200,FIQ-101,软水总管流量,B,m3/h,7.2, 0, 0
3,200,FIQ-102,蒸汽总管蒸汽流量,L,m3/h,7.2, 0, 0
3,200,FIQ-103,进汽包软水流量,L,m3/h,7.2, 0, 0
3,200,FIQ-104,进汽包软水流量,B,m3/h,7.2, 0, 0
3,200,FIQ-105,进汽包软水流量,L,m3/h,7.2, 0, 0
3,200,FRC-109,一塔尔端补一端流量,L,m3/h,7.2, 0, 0
3,200,FI-110,一塔采出流量,L,m3/h,7.2, 0, 0
3,200,FI-111,二塔补一塔流量,L,m3/h,7.2, 0, 0
3,200,FI-112,二塔补一次水流量,L,m3/h,7.2, 0, 0
3,200,FRC-114,醛塔进料流量,DCS,m3/h,7.2, 0, 0
3,200,FI-201,乙醛采出流量,DCS,m3/h,7.2, 0, 0
3,200,FI-202,醛塔回流流量,DCS,m3/h,7.2, 0, 0
3,200,FI-203,酒塔回流流量,DCS,m3/h,7.2, 0, 0
3,200,FI-204,酒塔采出流量,T,m3/h,7.2, 0, 0
3,200,FRC-301,进氧化塔空气流量,JT,m3/h,7.2, 0, 0
3,200,FRC-302,进氧化塔空气流量,JT,m3/h,7.2, 0, 0
3,200,FRC-303,进氧化塔空气流量,KBL,m3/h,7.2, 0, 0
3,200,FRC-304,进氧化塔空气流量,BL,m3/h,7.2, 0, 0
3,200,FRC-305,进氧化塔空气流量,BL,m3/h,7.2, 0, 0
3,200,FI-308,进氧化塔醛流量,DCS,m3/h,7.2, 0, 0
3,200,FI-309,循环锰流量,DCS,m3/h,7.2, 0, 0
3,200,FI-306,进空气分配盘空气流量,DCS,m3/h,7.2, 0, 0
3,200,LIC-101,1#蒸发锅液位,DCS,%,7.2, 0, 0
3,200,LIC-102,2#蒸发锅液位,DCS,%,7.2, 0, 0
3,200,LIC-103,3#蒸发锅液位,DCS,%,7.2, 0, 0
3,200,LIC-105,1#汽包液位,DCS,%,7.2, 0, 0
3,200,LIC-107,2#汽包液位,DCS,%,7.2, 0, 0
3,200,LIC-109,3#汽包液位,BL,%,7.2, 0, 0
3,200,LI-114,一塔塔釜液位,BL,%,7.2, 0, 0
3,200,LIC-117,一吸塔二段液位,DCS,%,7.2, 0, 0
3,200,LIC-118,二吸塔液位,DCS,%,7.2, 0, 0
3,200,LRC-202,醛塔塔釜液位,DCS,%,7.2, 0, 0
3,200,LRC-204,醛塔回流槽液位,DCS,%,7.2, 0, 0
3,200,LI-413,成品锅液位,DCS,%,7.2,0,0
3,200,LICA-212,酒塔塔釜液位,DCS,%,7.2, 0, 0
3,200,LICA-215,酒塔回流槽液位,DCS,%,7.2, 0, 0
3,200,LIC-302,氧化塔塔顶液位,DCS,%,7.2, 0, 0
3,200,LIC-307,粗醋酸储槽液位,DCS,%,7.2, 0, 0
3,200,LI-310,醛塔回流槽液位,DCS,%,7.2, 0, 0
3,200,LIC-403,浓缩塔塔釜液位,DCS,%,7.2, 0, 0
3,200,LICA-406,汽水分离器液位,DCS,%,7.2, 0, 0
3,200,LICA-411,成品分离器液位,DCS,%,7.2, 0, 0
3,200,LI-412,高沸锅液位,DCS,%,7.2,0,0
3,200,TRA-108,1#氧化炉上层温度,DCS,℃,7.2, 0, 0
3,200,TRA-110,2#氧化炉上层温度,DCS,℃,7.2, 0, 0
3,200,TRA-112,3#氧化炉上层温度,DCS,℃,7.2, 0, 0
3,200,TRA-126,1#氧化炉中层温度,DCS,℃,7.2, 0, 0
3,200,TRA-127,2#氧化炉中层温度,DCS,℃,7.2, 0, 0
3,200,TRA-128,3#氧化炉中层温度,DCS,℃,7.2, 0, 0
3,200,TRA-129,1#氧化炉下层温度,DCS,℃,7.2, 0, 0
3,200,TRA-130,2#氧化炉下层温度,DCS,℃,7.2, 0, 0
3,200,TRA-131,3#氧化炉下层温度,DCS,℃,7.2, 0, 0
3,200,FI-401,浓缩塔回流流量,DCS,m3/h,7.2,0,0
3,200,TRC-101,1#蒸发锅温度,DCS,℃,7.2, 0, 0
3,200,TRC-103,2#蒸发锅温度,DCS,℃,7.2, 0, 0
3,200,TRC-105,3#蒸发锅温度,DCS,℃,7.2, 0, 0
3,200,TRCA-107,1#过热器温度,DCS,℃,7.2, 0, 0
3,200,TRCA-109,2#过热器温度,DCS,℃,7.2, 0, 0
3,200,TRCA-111,3#过热器温度,DCS,℃,7.2, 0, 0
3,200,TRC-201,预热温度,DCS,℃,7.2, 0, 0
3,200,TRC-208,酒塔塔顶温度,DCS,℃,7.2, 0, 0
3,200,TR-204,醛塔灵敏板温度,DCS,℃,7.2, 0, 0
3,200,TR-205,醛塔中温度,DCS,℃,7.2, 0, 0
3,200,TR-206,醛塔釜温度,DCS,℃,7.2, 0, 0
3,200,TR-209,酒塔中温度,DCS,℃,7.2, 0, 0
3,200,TR-203,醛塔塔顶温度,DCS,℃,7.2, 0, 0
3,200,TR-210,酒塔釜温度,DCS,℃,7.2, 0, 0
3,200,TRC-301,氧化塔一段温度,DCS,℃,7.2, 0, 0
3,200,TRC-302,氧化塔二段温度,DCS,℃,7.2, 0, 0
3,200,TRC-303,氧化塔三段温度,DCS,℃,7.2, 0, 0
3,200,TRC-304,氧化塔四段温度,DCS,℃,7.2, 0, 0
3,200,TRC-305,氧化塔五段温度,DCS,℃,7.2, 0, 0
3,200,TRC-306,氧化塔六段温度,DCS,℃,7.2, 0, 0
3,200,TR-307,氧化塔顶温度,DCS,℃,7.2, 0, 0
3,200,TRC-309,氧化塔釜温度,DCS,℃,7.2, 0, 0
3,200,TRC-401,高沸锅温度,DCS,℃,7.2, 0, 0
3,200,TRC-402,浓缩塔顶温度,DCS,℃,7.2, 0, 0
3,200,TR-403,浓缩塔中温度,DCS,℃,7.2, 0, 0
3,200,TRC-404,浓缩塔釜温度,DCS,℃,7.2, 0, 0
3,200,TRC-405,成品锅温度,DCS,℃,7.2, 0, 0
3,200,TI-406,预热温度,DCS,℃,7.2, 0, 0
3,200,TI-123,二塔塔顶温度,DCS,℃,7.2, 0, 0
3,200,TI-132,一吸塔上塔顶温,DCS,℃,7.2, 0, 0
3,200,TI-133,一体塔上塔釜温度,DCS,℃,7.2, 0, 0
3,200,TI-134,一吸塔底塔顶温度,DCS,℃,7.2, 0, 0
3,200,TI-135,一吸塔底塔釜温度,DCS,℃,7.2, 0, 0
3,200,TI-136,二吸塔塔底温度,DCS,℃,7.2, 0, 0
3,200,TI-137,一吸塔上塔换热出口温,DCS,℃,7.2, 0, 0
3,200,TI-138,一吸塔底塔换热出口温,DCS,℃,7.2, 0, 0
3,200,TI-139,二吸塔换热出口温度,DCS,℃,7.2, 0, 0
3,200,TI-140,一次水换热出口温度,DCS,℃,7.2, 0, 0
3,200,TRC-101O,1#蒸发锅温度调节,DCS,%,7.2, 0, 0
3,200,TRC-103O,2#蒸发锅温度调节,DCS,%,7.2, 0, 0
3,200,TRC-105O,3#蒸发锅温度调节,DCS,%,7.2, 0, 0
3,200,TRC-107O,过热器温度调节,DCS,%,7.2, 0, 0
3,200,TRC-109O,过热器温度调节,DCS,%,7.2, 0, 0
3,200,TRCA-111O,过热器温度调节,DCS,%,7.2, 0, 0
3,200,TRC-201O,预热温度调节,DCS,%,7.2, 0, 0
3,200,TRC-208O,酒塔塔顶温度调节,DCS,%,7.2, 0, 0
3,200,TRC-301O,氧化塔一段温度调节,DCS,%,7.2, 0, 0
3,200,TRC-302O,氧化塔二段温度调节,DCS,%,7.2, 0, 0
3,200,TRC-303O,氧化塔三段温度调节,DCS,%,7.2, 0, 0
3,200,TRC-304O,氧化塔四段温度调节,DCS,%,7.2, 0, 0
3,200,TRC-305O,氧化塔五段温度调节,DCS,%,7.2, 0, 0
3,200,TRC-306O,氧化塔六段温度调节,DCS,%,7.2, 0, 0
3,200,TRC-309O,氧化塔塔釜温度调节,DCS,%,7.2, 0, 0
3,200,TRC-401O,高沸锅温度调节,DCS,%,7.2, 0, 0
3,200,TRC-402O,浓缩塔顶温调节,DCS,%,7.2, 0, 0
3,200,TRC-404O,浓缩塔釜温调节,DCS,%,7.2, 0, 0
3,200,TRC-405O,成品锅温度调节,DCS,%,7.2, 0, 0
3,200,PRC-102O,2#蒸汽总管压力调节,DCS,%,7.2, 0, 0
3,200,PRC-202O,醛塔塔釜压力调节,DCS,%,7.2, 0, 0
3,200,PRC-203O,醛塔塔顶压力调节,DCS,%,7.2, 0, 0
3,200,PRC-219O,酒塔塔釜压力调节,DCS,%,7.2, 0, 0
3,200,PRC-304O,空气缓冲罐压力调节,DCS,%,7.2, 0, 0
3,200,FRC-305O,进氧化塔空气流量调节,DCS,%,7.2, 0, 0
3,200,LIC-101O,1#蒸发锅液位调节,DCS,%,7.2, 0, 0
3,200,LIC-102O,2#蒸发锅液位调节,DCS,%,7.2, 0, 0
3,200,LIC-103O,3#蒸发锅液位调节,DCS,%,7.2, 0, 0
3,200,LIC-105O,软水流量调节,DCS,%,7.2, 0, 0
3,200,LIC-107O,软水流量调节,DCS,%,7.2, 0, 0
3,200,LIC-109O,软水流量调节,DCS,%,7.2, 0, 0
3,200,LIC-117O,一吸塔二段液位调节,DCS,%,7.2, 0, 0
3,200,LIC-118O,二吸塔液位调节,DCS,%,7.2, 0, 0
3,200,LIC-204O,醛塔回流槽液位调节,DCS,%,7.2, 0, 0
3,200,LICA-212O,酒塔塔釜液位调节,DCS,%,7.2, 0, 0
3,200,LICA-202O,醛塔塔釜液位调节,DCS,%,7.2, 0, 0
3,200,LIC-302O,氧化塔塔顶液位调节,DCS,%,7.2, 0, 0
3,200,LRC-307O,粗醋酸储槽液位调节,DCS,%,7.2, 0, 0
3,200,LIC-403O,醛塔塔釜液位调节,DCS,%,7.2, 0, 0
3,200,LRCA-215O,醛塔回流槽液位调节,DCS,%,7.2, 0, 0
3,200,LIC-411O,成品分离器液位调节,DCS,%,7.2, 0, 0
3,200,LIC-114O,一塔塔釜液位调节,DCS,%,7.2, 0, 0
3,200,FIC-114O,醛塔进料流量调节,DCS,%,7.2, 0, 0
3,200,PRC-313O,氧化塔塔顶压力调节,DCS,%,7.2, 0, 0
3,200,FRC-301O,进氧化塔空气流量调节,DCS,%,7.2, 0, 0
3,200,FRC-302O,进氧化塔空气流量调节,DCS,%,7.2, 0, 0
3,200,FRC-303O,进氧化塔空气流量调节,DCS,%,7.2, 0, 0
3,200,FRC-304O,进氧化塔空气流量调节,DCS,%,7.2, 0, 0
3,200,FI-308O,进氧化塔醛流量调节,DCS,m3/h,7.2,0,0
3,200,FI-112O,二塔补一次水流量调节,DCS,m3/h,7.2,0,0
3,200,FI-201O,醛塔采出流量调节,DCS,m3/h,7.2,0,0
3,200,LI-406O,汽水分离器液位调节,DCS,%,7.2,0,0
3,200,HC-201,醛塔二冷手操,DCS,%,7.2, 0, 0
3,200,HC-202,醛塔一冷手操,DCS,%,7.2, 0, 0
3,200,TRC-101S,1#蒸发锅温度设定,DCS,℃,7.2,0,0
3,200,TRC-103S,2#蒸发锅温度设定,DCS,℃,7.2,0,0
3,200,TRC-105S,3#蒸发锅温度设定,DCS,℃,7.2,0,0
3,200,TRC-107S,过热器温度设定,DCS,℃,7.2,0,0
3,200,TRC-109S,过热器温度设定,DCS,℃,7.2,0,0
3,200,TRCA-111S,过热器温度设定,DCS,℃,7.2,0,0
3,200,TRC-201S,预热器温度设定,DCS,℃,7.2,0,0
3,200,TRC-208S,酒塔塔顶温度设定,DCS,℃,7.2,0,0
3,200,TRC-301S,氧化塔一段温度设定,DCS,℃,7.2,0,0
3,200,TRC-302S,氧化塔二段温度设定,DCS,℃,7.2,0,0
3,200,TRC-303S,氧化塔三段温度设定,DCS,℃,7.2,0,0
3,200,TRC-304S,氧化塔四段温度设定,DCS,℃,7.2,0,0
3,200,TRC-305S,氧化塔五段温度设定,DCS,℃,7.2,0,0
3,200,TRC-306S,氧化塔六段温度设定,DCS,℃,7.2,0,0
3,200,TRC-309S,氧化塔塔釜温度设定,DCS,℃,7.2,0,0
3,200,TRC-401S,预热温度设定,DCS,℃,7.2,0,0
3,200,TRC-402S,浓缩塔顶温度设定,DCS,℃,7.2,0,0
3,200,TRC-404S,浓缩塔釜温度设定,DCS,℃,7.2,0,0
3,200,TRC-405S,成品锅温度设定,DCS,℃,7.2,0,0
3,200,PRC-102S,2#蒸汽总管压力设定,DCS,MPa,7.2,0,0
3,200,PRC-202S,醛塔塔釜压力设定,DCS,MPa,7.2,0,0
3,200,PRC-203S,醛塔塔顶压力设定,DCS,MPa,7.2,0,0
3,200,PRC-219S,酒塔塔釜压力设定,DCS,MPa,7.2,0,0
3,200,PRC-304S,空气缓冲罐压力设定,DCS,MPa,7.2,0,0
3,200,PRC-313S,氧化塔顶压力设定,DCS,MPa,7.2,0,0
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -