 "Notes:\n"
 "\n"
 "(1) If the primary measurement function is diode or continuity, this "
 "attribute returns the maximum forward voltage of a junction at "
 "approximately 0.7 mA.\n"

2 all "Secondary Auto Range Value" FL45_ATTR_SECONDARY_AUTO_RANGE_VALUE ViReal64 g 
 "Always returns the actual range the DMM is currently using for the "
 "secondary measurement.  The secondary measurement function is always "
 "auto-ranging.  The value is in units appropriate for the "
 "FL45_ATTR_SECONDARY_FUNCTION attribute as shown below.\n"
 "  \n"
 "   DC Volts - volts\n"
 "   AC Volts - volts\n"
 "   DC Current - amperes\n"
 "   AC Current - amperes\n"
 "   2-Wire Resistance - ohms\n"
 "   Frequency - hertz\n"
 "   Diode - volts\n"
 "\n"
 "(1) If the secondary measurement function is diode, this attribute returns "
 "the maximum forward voltage of a junction at approximately 0.7 mA\n"

2 all "Resolution" FL45_ATTR_RESOLUTION ViReal64 gs attrResolutionRangeTable 
 "Specifies the measurement resolution in digits of precision.\n"
 "    Setting this attribute to higher values increases the measurement "
 "accuracy.  Setting this attribute to lower values increases the "
 "measurement speed.  I\n"
 "\n"
 "Notes:\n"
 "\n"
 "(1) If the secondary measurement function is enabled, then this attribute "
 "also specifies the resolution of the secondary measurement.\n"

2 all "Trigger Source" FL45_ATTR_TRIGGER_SOURCE ViInt32 gs attrTriggerSourceRangeTable 
 "Specifies the trigger source.  After you call one of the FL45_Measure, "
 "FL45_Read, or FL45_Initiate functions, the DMM waits for the trigger you "
 "specify with this attribute.  After it receives the trigger, the DMM waits "
 "the length of time you specify with the FL45_ATTR_TRIGGER_DELAY attribute. "
 " The DMM then takes a measurement.\n"

2 all "Trigger Delay" FL45_ATTR_TRIGGER_DELAY ViReal64 gs 
 "This attribute specifies the value you want to use for the trigger delay.  "
 "Express this value in seconds.\n"
 "\n"
 "The trigger delay specifies the length of time the DMM waits after it "
 "receives the trigger and before it takes a measurement.\n"
 "\n"
 "The FL45 allows only auto-delay enabled or no delay at all.  You cannot "
 "set the FL45 to a manual delay value other than 0.0.  The driver reserves "
 "negative values for configuring the DMM to calculate the trigger delay "
 "automatically.\n"
 "\n"
 "Defined Constant Values:\n"
 "FL45_VAL_AUTO_DELAY_ON  - Auto-delay on\n"
 "\n"
 "Valid Manual Range: 0.0 (seconds)\n"
 "\n"
 "Default Value: FL45_VAL_AUTO_DELAY_ON\n"
 "\n"
 "Notes:\n"
 "\n"
 "(1) Setting this parameter to FL45_VAL_AUTO_DELAY_ON configures the DMM to "
 "calculate the best trigger delay before each measurement.\n"

2 all "AC Minimum Frequency" FL45_ATTR_AC_MIN_FREQ ViReal64 gs 
 "Specifies the minimum frequency component of the input signal for AC "
 "measurements. The value of this attribute affects instrument behavior only "
 "when you set the FL45_ATTR_FUNCTION attribute to an AC measurement.\n"
 "\n"
 "Valid Range:  The valid range depends on AC measurement as shown below.\n"
 "\n"
 "AC Volts: 20.0 to 100.0E3 Hz\n"
 "AC Current: 20.0 to 20.0E3 Hz\n"
 "AC+DC Volts: 20.0 to 100.0E3 Hz\n"
 "AC+DC Current: 20.0 to 20.0E3 Hz\n"
 "\n"
 "When you set the Measurement Function to AC Current or to AC+DC Current "
 "and set the Range to a value greater than 0.1 A, then the maximum value "
 "the DMM allows for this parameter decreases to 2.0 kHz.\n"
 "\n"
 "Notes:\n"
 "\n"
 "(1) The driver coerces all valid values you pass for this parameter to "
 "20.0 Hz.\n"

2 all "AC Maximum Frequency" FL45_ATTR_AC_MAX_FREQ ViReal64 gs 
 "Specifies the maximum frequency component of the input signal for AC "
 "measurements. The value of this attribute affects instrument behavior only "
 "when you set the FL45_ATTR_FUNCTION attribute to an AC measurement.\n"
 "\n"
 "Valid Range:  The valid range depends on AC measurement function as shown "
 "below.\n"
 "\n"
 "AC Volts: 20.0 to 100.0E3 Hz\n"
 "AC Current: 20.0 to 20.0E3 Hz\n"
 "AC+DC Volts: 20.0 to 100.0E3 Hz\n"
 "AC+DC Current: 20.0 to 20.0E Hz\n"
 "\n"
 "When you set the Measurement Function to AC Current or to AC+DC Current "
 "and set the Range to a value greater than 0.1 amperes, then the maximum "
 "value the DMM allows for this parameter decreases to 2.0 kHz.\n"
 "\n"
 "Notes:\n"
 "\n"
 "(1) The driver coerces all valid values you pass for this parameter to the "
 "maximum frequency.\n"

2 all "Aperture Time" FL45_ATTR_APERTURE_TIME ViReal64 g 
 "Returns the measurement aperture time for the current configuration.  The "
 "units for this attribute are seconds.\n"

2 all "Aperture Time Units" FL45_ATTR_APERTURE_TIME_UNITS ViInt32 g 
 "Returns the units for the attribute FL45_ATTR_APERTURE_TIME.  Aperture "
 "time is always given in units of seconds.\n"
 "\n"
 "Possible values are the following:\n"
 "FL45_VAL_SECONDS\n"
 "  "

1 all "Advanced Triggering" 
 "Attributes for acquiring data on multiple triggers and multiple "
 "measurements per trigger.\n"
 "    "

1 all "Miscellaneous" 
 "Miscellaneous attributes.\n"
 "    "

1 all "Function Modifiers" 
 "Attributes that control the FLuke 45 function modifiers.  A function "
 "modifier causes the meter to modify the normal operation of a measurement "
 "function (or perform an action on a measurement) before displaying a "
 "reading.  For example, the relative modifier causes the meter to display "
 "the difference between a measured value and the relative base."

2 all "Decibel Modifier" 
 "This group specifies attributes for turning on/off and configuring a "
 "decibel modifier.  A modifier causes the DMM to modify the normal "
 "operation of a measurement function (or performs an action on a "
 "measurement) before displaying a reading.\n"

3 all "dB Mode" FL45_ATTR_DB_MODE ViInt32 gs attrDbModeRangeTable 
 "Specifies the decibel modifier to use.  The DMM must be in a voltage "
 "measurement function before this attribute can be set to a decibel "
 "modifier.\n"
 "\n"
 "When you enable a decibel modifier, the readings you obtain from the "
 "FL45_Measure, FL45_Read, and FL45_Fetch functions are in the  decibel "
 "units you configure with this function.\n"
 "\n"
 "Notes:\n"
 "\n"
 "(1) You can use the decibel modifiers for only voltage measurement "
 "functions.\n"

3 all "dB Reference Impedance" FL45_ATTR_DB_REF ViInt32 gs attrDbRefRangeTable 
 "Specifies the reference impedance used for the decibel modifier.\n"
 "\n"
 "If you set the Decibel Mode to dB Power, the valid impedance values are 2, "
 "4, 8, or 16 ohms.\n"
 "\n"
 "Note:\n"
 "\n"
 "(1) This parameter affects instrument behavior only when you enable one of "
 "the decibel modifier's calculation modes.\n"

2 all "Hold Modifier" 
 "This group contains attributes that control the DMM's hold  modifier. The "
 "hold modifier configures the DMM to take a new measurement only when the "
 "input signal is stable and 'hold' that measurement on the display. This "
 "feature can be particularly advantageous in difficult or hazardous "
 "circumstances when you might want to keep your eyes fixed on the probes, "
 "and then read the display when it is safe or convenient to do so."

3 all "Hold Enable" FL45_ATTR_HOLD_ENABLE ViBoolean gs Boolean_values 
 "Specifies whether to enable the hold modifier.  VI_TRUE enables the "
 "modifier, and VI_FALSE disables the modifier.  The hold modifier "
 "configures the DMM to take a new measurement only when the input signal is "
 "stable and 'hold' the measurement on the display.  This feature can be "
 "particularly advantageous in difficult or hazardous circumstances when you "
 "might want to keep your eyes fixed on the probes, and then read the "
 "display when it is safe or convenient to do so.\n"
 "\n"
 "Notes:\n"
 "\n"
 "(1) Use the FL45_Hold() function to force a new reading to be displayed.  "
 "When a new, stable reading is detected, a beep is emitted, and the display "
 "is automatically updated.\n"
 "\n"
 "(2) The FL45_Hold() function should be called before the trigger occurs.  "
 "For example if you are using the software triggering mechanism.  Then the "
 "order of function calls should be:\n"
 "\n"
 "  FL45_Initiate ();\n"
 "  FL45_Hold ();\n"
 "  FL45_SendSWTrigger ();\n"

3 all "Hold Threshold" FL45_ATTR_HOLD_THRESHOLD ViInt32 gs attrHoldThresholdRangeTable 
 "Specifies the hold measurement threshold. The DMM takes a new measurement "
 "only when the input signal is as stable as you specify with this "
 "attribute.\n"
 "\n"
 "Notes:\n"
 "\n"
 "(1) This attribute affects instrument behavior only when you set the "
 "FL45_ATTR_HOLD_ENABLE attribute to VI_TRUE.\n"
 "    "

2 all "Compare Modifier" 
 "This group specifies attributes for turning on/off and configuring the "
 "compare modifier. The compare provides an easy way to determine if a "
 "reading falls within a designated range of values.\n"

3 all "Compare Enable" FL45_ATTR_COMPARE_ENABLE ViBoolean gs Boolean_values 
 "Specifies whether to enable the compare modifier.  VI_TRUE enables the "
 "compare modifier, and VI_FALSE disables the compare modifier.\n"
 "\n"
 "The compare modifier provides an easy way to determine if a reading falls "
 "within a range you specify.  You specify the range with the High Value and "
 "Low Value parameters.  Enabling the compare modifier automatically enables "
 "the hold modifier.  Disabling the hold does not affect the compare "
 "modifier.\n"
 "\n"
 "Use the FL45_FetchCompare function to obtain the comparison result.\n"

3 all "Compare Low" FL45_ATTR_COMPARE_LOW ViReal64 s 
 "Specifies the low comparison value.  You cannot query this attribute.  \n"
 "\n"
 "The value you specify for the FL345_ATTR_FUNCTION attribute determines the "
 "units of this attribute as shown below.\n"
 "  \n"
 "DC Volts - volts\n"
 "AC Volts - volts\n"
 "DC Current - amperes\n"
 "AC Current  - amperes\n"
 "2-Wire Resistance - ohms\n"
 "AC plus DC Volts - volts\n"
 "AC plus DC Current - amperes\n"
 "Frequency - hertz\n"
 "Diode - volts\n"
 "Continuity - volts\n"
 "\n"
 "Valid range: The value must be within the boundaries (inclusive) of the "
 "selected measurement range.  The value can be positive or negative.\n"

3 all "Compare High" FL45_ATTR_COMPARE_HIGH ViReal64 s 
 "Specifies the high comparison value.  You cannot query this attribute.  \n"
 "\n"
 "The value you specify for the FL345_ATTR_FUNCTION attribute determines the "
 "units of this attribute as shown below.\n"
 "  \n"
 "DC Volts - volts\n"
 "AC Volts - volts\n"
 "DC Current - amperes\n"
 "AC Current  - amperes\n"
 "2-Wire Resistance - ohms\n"
 "AC plus DC Volts - volts\n"
 "AC plus DC Current - amperes\n"
 "Frequency - hertz\n"
 "Diode - volts\n"
 "Continuity - volts\n"
 "\n"
 "Valid range: The value must be within the boundaries (inclusive) of the "
 "selected measurement range.  The value can be positive or negative.\n"

2 all "Min Max Modifier" 
 "This group specifies attributes for turning on/off and configuring the "
 "min-max modifier.\n"

3 all "Min Max Mode" FL45_ATTR_MIN_MAX_MODE ViInt32 gs attrMinMaxModeRangeTable 
 "Specifies whether to enable the min-max modifier and whether the min or "
 "max value should be displayed.  Enabling this modifier automatically "
 "disables auto-ranging.\n"
 "\n"
 "Each time the DMM takes a measurement, it compares the measured value "
 "against the minimum and maximum values.  If the measured value is less "
 "than the minimum value, the DMM saves the measured value as the new "
 "minimum value.  If the measured value is greater than the maximum value, "
 "the DMM saves the measured value as the new maximum value.\n"
 "\n"
 "Note: \n"
 "\n"
 "(1) You us the FL45_FetchMinMax function to obtain the minimum and maximum "
 "values.\n"
 "    "

3 all "Min Max Maximum" FL45_ATTR_MIN_MAX_MAX ViReal64 s 
 "Specifier the value you want to use for the initial maximum value for the "
 "min-max modifier.  You cannot query this attribute\n"
 "\n"
 "The value you specifies for the FL45_ATTR_FUNCTION attribute determines "
 "the units of this attribute as shown below.\n"
 "  \n"
 "DC Volts - volts\n"
 "AC Volts - volts\n"
 "DC Current - amperes\n"
 "AC Current - amperes\n"
 "2-Wire Resistance - ohms\n"
 "AC plus DC Volts - volts\n"
 "AC plus DC Current - amperes\n"
 "Frequency - hertz\n"
 "Diode - volts\n"
 "Continuity - volts\n"
 "\n"
 "Valid range: The value must be within the boundaries (inclusive) of the "
 "selected measurement range.  The value can be positive or negative.\n"
 "\n"
 "(1) This parameter affects instrument behavior only when you set the "
 "Min-Max Mode parameter to FL45_VAL_MIN_MODE or to FL45_VAL_MAX_MODE.\n"

3 all "Min Max Minimum" FL45_ATTR_MIN_MAX_MIN ViReal64 s 
 "Specifier the value you want to use for the initial minimum value for the "
 "min-max modifier.  You cannot query this attribute\n"
 "\n"
 "The value you specifies for the FL45_ATTR_FUNCTION attribute determines "
 "the units of this attribute as shown below.\n"
 "  \n"
 "DC Volts - volts\n"
 "AC Volts - volts\n"
 "DC Current - amperes\n"
 "AC Current - amperes\n"
 "2-Wire Resistance - ohms\n"
 "AC plus DC Volts - volts\n"
 "AC plus DC Current - amperes\n"
 "Frequency - hertz\n"
 "Diode - volts\n"
 "Continuity - volts\n"
 "\n"
 "Valid range: The value must be within the boundaries (inclusive) of the "
 "measurement range.  The value can be positive or negative.\n"
 "\n"
 "(1) This parameter affects instrument behavior only when you set the "
 "Min-Max Mode parameter to FL45_VAL_MIN_MODE or to FL45_VAL_MAX_MODE.\n"
 "    "

2 all "Relative Modifier" 
 "This group specifies the attributes for turning on/off and configuring the "
 "relative modifier.\n"

3 all "Relative Enable" FL45_ATTR_RELATIVE_ENABLE ViBoolean gs Boolean_values 
 "Specifies whether to enable the relative modifier.  When the relative "
 "modifier is enabled, the DMM returns all measured values relative to a "
 "base value.  You specify the base value with the FL45_ATTR_RELATIVE_BASE "
 "attribute.  For example, if the relative base is 15.00 volts, and the "
 "present reading is 14.10 volts, the DMM returns -0.90 volts as the result "
 "of the FL45_Measure, FL45_Read, and FL45_Fetch functions.\n"
 "\n"
 "Enabling the modifier automatically disables auto-ranging. When the "
 "relative modifier is first enabled, the DMM stores the last valid reading "
 "as the relative base.  if a last valid reading does not exist, then the "
 "relative base is set to 0.0.\n"

3 all "Relative Base" FL45_ATTR_RELATIVE_BASE ViReal64 gs 
 "Specifies the instruments base value with which the DMM makes relative "
 "readings. You cannot access this attribute unless the "
 "FL45_ATTR_RELATIVE_MODE is set to VI_TRUE. \n"
 "\n"
 "The value you specifies for the FL45_ATTR_FUNCTION attribute determines "
 "the units of this attribute as shown below.\n"
 "  \n"
 "DC Volts - volts\n"
 "AC Volts - volts\n"
 "DC Current - amperes\n"
 "AC Current - amperes\n"
 "2-Wire Resistance - ohms\n"
 "AC plus DC Volts - volts\n"
 "AC plus DC Current - amperes\n"
 "Frequency - hertz\n"
 "Diode - volts\n"
 "Continuity - volts\n"
 "\n"
 "Valid range: The value must be within the boundaries (inclusive) of the "
 "selected measurement range.  The value can be positive or negative.\n"
 "    "

1 all "Miscellaneous Attributes" 
 "Additional Attributes."

2 all "ID Query Response" FL45_ATTR_ID_QUERY_RESPONSE ViString g 
 "Returns the ID Query response string.  The instrument driver gets the "
 "value of this attribute when you pass VI_TRUE for the ID Query parameter "
 "to the FL45_init or FL45_InitWithOptions function.\n"
 "    "

2 all "OPC Callback Timeout" FL45_ATTR_OPC_TIMEOUT ViInt32 hidden 
 "This attribute is hidden.  The driver uses this attribute internally to "
 "set the timeout for the OPC callback.\n"
 "    "

2 all "FL45_ATTR_MATH_MODIFIERS" FL45_ATTR_MATH_MODIFIERS ViInt32 hidden 
 ""