📄 ieee802dot11mib.mib
字号:
-- **********************************************************************-- * IEEE 802.11 Management Information Base-- **********************************************************************IEEE802dot11-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,Unsigned32, Integer32, Counter32 FROM SNMPv2-SMI DisplayString , MacAddress, RowStatus, TruthValue FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF ifIndex FROM RFC1213-MIB;-- **********************************************************************-- * MODULE IDENTITY-- ********************************************************************** ieee802dot11 MODULE-IDENTITY LAST-UPDATED "9807080000Z" ORGANIZATION "IEEE 802.11" CONTACT-INFO "WG E-mail: stds-802-11@ieee.org Chair: Vic Hayes Postal: Lucent Technologies, Inc. Zadelstede 1-10 Nieuwegein, Netherlands 3431 JZ Tel: +31 30 609 7528 Fax: +31 30 231 6233 E-mail: vichayes@lucent.com Editor: Bob O'Hara Postal: Informed Technology, Inc. 1750 Nantucket Circle, Suite 138 Santa Clara, CA 95054 USA Tel: +1 408 986 9596 Fax: +1 408 727 2654 E-mail: bob@informed-technology.com" DESCRIPTION "The MIB module for IEEE 802.11 entities. iso(1).member-body(2).us(840).ieee802dot11(10036)" ::= { 1 2 840 10036 }-- **********************************************************************-- * Major sections-- **********************************************************************-- Station ManagemenT (SMT) Attributes -- DEFINED AS "The SMT object class provides the necessary support at the -- station to manage the processes in the station such that the -- station may work cooperatively as a part of an IEEE 802.11 network."; dot11smt OBJECT IDENTIFIER ::= {ieee802dot11 1} -- dot11smt GROUPS -- dot11StationConfigTable ::= {dot11smt 1} -- dot11AuthenticationAlgorithmsTable ::= {dot11smt 2} -- dot11WEPDefaultKeysTable ::= {dot11smt 3} -- dot11WEPKeyMappingsTable ::= {dot11smt 4} -- dot11PrivacyTable ::= {dot11smt 5} -- dot11SMTnotification ::= {dot11smt 6}-- MAC Attributes -- DEFINED AS "The MAC object class provides the necessary support -- for the access control, generation, and verification of frame check -- sequences, and proper delivery of valid data to upper layers."; dot11mac OBJECT IDENTIFIER ::= {ieee802dot11 2} -- MAC GROUPS -- reference IEEE Std 802.1f-1993 -- dot11OperationTable ::= {dot11mac 1} -- dot11CountersTable ::= {dot11mac 2} -- dot11GroupAddressesTable ::= {dot11mac 3}-- Resource Type ID dot11res OBJECT IDENTIFIER ::= {ieee802dot11 3} dot11resAttribute OBJECT IDENTIFIER ::= {dot11res 1 }-- PHY Attributes -- DEFINED AS "The PHY object class provides the necessary support -- for required PHY operational information that may vary from PHY -- to PHY and from STA to STA to be communicated to upper layers." dot11phy OBJECT IDENTIFIER ::= {ieee802dot11 4} -- phy GROUPS -- dot11PhyOperationTable ::= {dot11phy 1}-- dot11PhyAntennaTable ::= {dot11phy 2} -- dot11PhyTxPowerTable ::= {dot11phy 3} -- dot11PhyFHSSTable ::= {dot11phy 4} -- dot11PhyDSSSTable ::= {dot11phy 5} -- dot11PhyIRTable ::= {dot11phy 6} -- dot11RegDomainsSupportedTable ::= {dot11phy 7} -- dot11AntennasListTable ::= {dot11phy 8} -- dot11SupportedDataRatesTxTable ::= {dot11phy 9} -- dot11SupportedDataRatesRxTable ::= {dot11phy 10}-- **********************************************************************-- * Textual conventions from 802 definitions-- ********************************************************************** WEPKeytype ::= OCTET STRING (SIZE (5))-- **********************************************************************-- * MIB attribute OBJECT-TYPE definitions follow-- **********************************************************************-- **********************************************************************-- * SMT Station Config Table-- **********************************************************************dot11StationConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11StationConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Station Configuration attributes. In tablular form to allow for multiple instances on an agent." ::= { dot11smt 1 }dot11StationConfigEntry OBJECT-TYPE SYNTAX Dot11StationConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11StationConfigTable. It is possible for there to be multiple IEEE 802.11 interfaces on one agent, each with its unique MAC address. The relationship between an IEEE 802.11 interface and an interface in the context of the Internet-standard MIB is one-to-one. As such, the value of an ifIndex object instance can be directly used to identify corresponding instances of the objects defined herein. ifIndex - Each 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX {ifIndex} ::= { dot11StationConfigTable 1 }Dot11StationConfigEntry ::= SEQUENCE { dot11StationID MacAddress, dot11MediumOccupancyLimit INTEGER, dot11CFPollable TruthValue, dot11CFPPeriod INTEGER, dot11CFPMaxDuration INTEGER, dot11AuthenticationResponseTimeOut Unsigned32, dot11PrivacyOptionImplemented TruthValue, dot11PowerManagementMode INTEGER, dot11DesiredSSID OCTET STRING, dot11DesiredBSSType INTEGER, dot11OperationalRateSet OCTET STRING, dot11BeaconPeriod INTEGER, dot11DTIMPeriod INTEGER, dot11AssociationResponseTimeOut Unsigned32, dot11DisassociateReason INTEGER, dot11DisassociateStation MacAddress, dot11DeauthenticateReason INTEGER, dot11DeauthenticateStation MacAddress, dot11AuthenticateFailStatus INTEGER, dot11AuthenticateFailStation MacAddress }dot11StationID OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS deprecated DESCRIPTION "The purpose of dot11StationID is to allow a manager to identify a station for its own purposes. This attribute provides for that eventuality while keeping the true MAC address independent. Its syntax is MAC address and default value is the station's assigned, unique MAC address." ::= { dot11StationConfigEntry 1 }dot11MediumOccupancyLimit OBJECT-TYPE SYNTAX INTEGER (0..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shall indicate the maximum amount of time, in TU, that a point coordinator may control the usage of the wireless medium without relinquishing control for long enough to allow at least one instance of DCF access to the medium. The default value of this attribute shall be 100, and the maximum value shall be 1000." ::= { dot11StationConfigEntry 2 }dot11CFPollable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "When this attribute is true, it shall indicate that the STA is able to respond to a CF-Poll with a data frame within a SIFS time. This attribute shall be false if the STA is not able to respond to a CF-Poll with a data frame within a SIFS time." ::= { dot11StationConfigEntry 3 }dot11CFPPeriod OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "The attribute shall describe the number of DTIM intervals between the start of CFPs. It is modified by MLME-START.request primitive."::= { dot11StationConfigEntry 4 }dot11CFPMaxDuration OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The attribute shall describe the maximum duration of the CFP in TU that may be generated by the PCF. It is modified by MLME-START.request primitive."::= { dot11StationConfigEntry 5 }dot11AuthenticationResponseTimeOut OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shall specify the number of TU that a responding STA should wait for the next frame in the authentication sequence." ::= { dot11StationConfigEntry 6 }dot11PrivacyOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute, when true, shall indicate that the IEEE 802.11 WEP option is implemented. The default value of this attribute shall be false." ::= { dot11StationConfigEntry 7 }dot11PowerManagementMode OBJECT-TYPE SYNTAX INTEGER { active(1), powersave(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shall specify the power management mode of the STA. When set to active, it shall indicate that the station is not in power-save mode. When set to powersave, it shall indicate that the station is in power-save mode. The power management mode is transmitted in all frames according to the rules in 7.1.3.1.7." ::= { dot11StationConfigEntry 8 }dot11DesiredSSID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute reflects the Service Set ID used in the DesiredSSID parameter of the most recent MLME_Scan.request. This value may be modified by an external management entity and used by the local SME to make decisions about the Scanning process." ::= { dot11StationConfigEntry 9 }dot11DesiredBSSType OBJECT-TYPE SYNTAX INTEGER { infrastructure(1), independent(2), any(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shall specify the type of BSS the station shall use when scanning for a BSS with which to synchronize. This value is used to filter Probe Response frames and Beacons. When set to infrastructure, the station shall only synchronize with a BSS whose Capability Information field has the ESS subfield set to 1. When set to independent, the station shall only synchronize with a BSS whose Capability Information field has the IBSS subfield set to 1. When set to any, the station may synchronize to either type of BSS." ::= { dot11StationConfigEntry 10 }dot11OperationalRateSet OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..126)) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shall specify the set of data rates at which the station may transmit data. Each octet contains a value representing a rate. Each rate shall be within the range from 2 to 127, corresponding to data rates in increments of 500 kb/s from 1 Mb/s to 63.5 Mb/s, and shall be supported (as indicated in the supported rates table) for receiving data. This value is reported in transmitted Beacon, Probe Request, Probe Response, Association Request, Association Response, Reassociation Request, and Reassociation Response frames, and is used to determine whether a BSS with which the station desires to synchronize is suitable. It is also used when starting a BSS, as specified in 10.3." ::= { dot11StationConfigEntry 11 }dot11BeaconPeriod OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shall specify the number of TU that a station shall use for scheduling Beacon transmissions. This value is transmitted in Beacon and Probe Response frames." ::= { dot11StationConfigEntry 12 }dot11DTIMPeriod OBJECT-TYPE SYNTAX INTEGER(1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shall specify the number of beacon intervals that shall elapse between transmission of Beacons frames containing a TIM element whose DTIM Count field is 0. This value is transmitted in the DTIM Period field of Beacon frames." ::= { dot11StationConfigEntry 13 }dot11AssociationResponseTimeOut OBJECT-TYPE SYNTAX Unsigned32(1..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shall specify the number of TU that a requesting STA should wait for a response to a transmitted association-request MMPDU." ::= { dot11StationConfigEntry 14 }dot11DisassociateReason OBJECT-TYPE SYNTAX INTEGER(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute holds the most recently transmitted Reason Code in a Disassociation frame. If no Disassociation frame has been transmitted, the value of this attribute shall
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -