📄 automod.htm
字号:
<!DOCTYPE HTML PUBLIC "-//IETF//DTD HTML//EN">
<html>
<head>
<meta http-equiv="Content-Type"
content="text/html; charset=iso-8859-1">
<meta name="GENERATOR" content="Microsoft FrontPage 2.0">
<title>CAutoModbus class</title>
</head>
<body bgcolor="#FFFFFF">
<p><font size="5"><strong>CAutoModbus </strong></font></p>
<p><font size="3"><strong>class CAutoModbus : public </strong></font><a
href="cmodbu.htm"><font size="3"><strong>CModbus</strong></font></a></p>
<p><font size="3">CAutoModbus class is almost identical </font><a
href="local.htm">CLocalModbus</a> , the difference is that this
class create an instance of automation objet inside <font
size="3">of </font><a href="Autosrv.htm">Modbus COM Server</a>,
this in out-process ActiveX server that is responsible for
actually open comm port , send and receive messages from a
slave.The objective is to share the same serial port among many
apps. The ActiveX server can be used with Visual Basic , Access ,
Excel , Word97 and other programs that support automation. The <a
href="Autosrv.htm">Modbus COM Server</a> do not necessarily have
to be on same machine because this class use DCOM function
CocreateInstaceEx for creating objects on other machines. You
need to install DCOM if you using win 95 before experiment this
class.</p>
<p><strong>#include "localmodbus.h"</strong></p>
<p><a href="cautombr.htm"><strong>Class Members</strong></a></p>
</body>