字号:
<!DOCTYPE HTML PUBLIC "-//IETF//DTD HTML 2.2//EN"><!--Converted with LaTeX2HTML 96.1 (Feb 5, 1996) by Nikos Drakos (nikos@cbl.leeds.ac.uk), CBLU, University of Leeds --><HTML><HEAD><TITLE>6.2 BioMuse</TITLE><META NAME="description" CONTENT="6.2 BioMuse"><META NAME="keywords" CONTENT="sensors"><META NAME="resource-type" CONTENT="document"><META NAME="distribution" CONTENT="global"><LINK REL=STYLESHEET HREF="sensors.css" tppabs="http://ccrma.stanford.edu/CCRMA/Courses/252/sensors/sensors.css"></HEAD><BODY BGCOLOR="#FFFFFF" TEXT="#000000" LANG="EN"> <A NAME="tex2html350" HREF="node27.html" tppabs="http://ccrma.stanford.edu/CCRMA/Courses/252/sensors/node27.html"><IMG WIDTH=37 HEIGHT=24 ALIGN=BOTTOM ALT="next" SRC="next_motif.gif" tppabs="http://ccrma.stanford.edu/Images//next_motif.gif"></A> <A NAME="tex2html348" HREF="node24.html" tppabs="http://ccrma.stanford.edu/CCRMA/Courses/252/sensors/node24.html"><IMG WIDTH=26 HEIGHT=24 ALIGN=BOTTOM ALT="up" SRC="up_motif.gif" tppabs="http://ccrma.stanford.edu/Images//up_motif.gif"></A> <A NAME="tex2html342" HREF="node25.html" tppabs="http://ccrma.stanford.edu/CCRMA/Courses/252/sensors/node25.html"><IMG WIDTH=63 HEIGHT=24 ALIGN=BOTTOM ALT="previous" SRC="previous_motif.gif" tppabs="http://ccrma.stanford.edu/Images//previous_motif.gif"></A> <BR><B> Next:</B> <A NAME="tex2html351" HREF="node27.html" tppabs="http://ccrma.stanford.edu/CCRMA/Courses/252/sensors/node27.html">6.3 Radio Baton</A><B>Up:</B> <A NAME="tex2html349" HREF="node24.html" tppabs="http://ccrma.stanford.edu/CCRMA/Courses/252/sensors/node24.html">6 System Integration</A><B> Previous:</B> <A NAME="tex2html343" HREF="node25.html" tppabs="http://ccrma.stanford.edu/CCRMA/Courses/252/sensors/node25.html">6.1 Data Acquisition system</A><BR> <P><H2><A NAME="SECTION00062000000000000000">6.2 BioMuse</A></H2><P>The <A NAME="tex2html46" HREF="javascript:if(confirm('http://www.sciam.com/1096issue/1096lustedbox1.html \n\n该文件未被 Teleport Pro 下载,因为 它位于起始地址以设置的边界以外的域或路径中。 \n\n你想要从服务器打开它吗?'))window.location='http://www.sciam.com/1096issue/1096lustedbox1.html'" tppabs="http://www.sciam.com/1096issue/1096lustedbox1.html">BioMuse</A>
system is a complete bioelectric controller system. All bioelectric signals
that can be measured from the surface of the skin can then be used to control the
computer. The system is composed of 8 instrumentation amplifier circuits (IA)
in order to measure 8 bioelectric
signals simultaneously. The amplified signal from the electrodes is then sent to a
programmable gain amplifier (PGA). The total gain is:
<IMG WIDTH=156 HEIGHT=17 ALIGN=TOP ALT="tex2html_wrap_inline2088" SRC="img125.gif" tppabs="http://ccrma.stanford.edu/CCRMA/Courses/252/sensors/img125.gif" >
Where <IMG WIDTH=75 HEIGHT=17 ALIGN=TOP ALT="tex2html_wrap_inline2090" SRC="img126.gif" tppabs="http://ccrma.stanford.edu/CCRMA/Courses/252/sensors/img126.gif" > and <IMG WIDTH=48 HEIGHT=17 ALIGN=TOP ALT="tex2html_wrap_inline2092" SRC="img127.gif" tppabs="http://ccrma.stanford.edu/CCRMA/Courses/252/sensors/img127.gif" > can be programmed from 1 to 100. Thus
the maximum <IMG WIDTH=102 HEIGHT=17 ALIGN=TOP ALT="tex2html_wrap_inline2094" SRC="img128.gif" tppabs="http://ccrma.stanford.edu/CCRMA/Courses/252/sensors/img128.gif" > .
The signal is then sampled at a rate of <IMG WIDTH=33 HEIGHT=14 ALIGN=BOTTOM ALT="tex2html_wrap_inline2096" SRC="img129.gif" tppabs="http://ccrma.stanford.edu/CCRMA/Courses/252/sensors/img129.gif" > . This signal is then processed by a
specialized digital signal processing microprocessor in order to filter the signal and
perform certain pattern recognition operations. This processed signal is then sent at
19.2kBaud to the computer using an optically isolated serial channel. The optical isolation
is important to protect the user from voltage spikes coming from the computer.<P><BR> <HR><P><ADDRESS><I>Tim Stilson <BR>Thu Oct 17 16:32:33 PDT 1996</I></ADDRESS></BODY></HTML>