📄 023-906-022-g.lbl
字号:
;
;VAG-COM Measuring Block Labels
;ECU p/n 023-906-022-G
;AAF Engines: 2.5L, 10 valve, OBD-1
;Digifant 1.2;
;MY 1993-2 USA/Canada Eurovan
;Based on: Robert Bently-Publication VD95.
;
; Tested: USA 005750 MY.93
; Errors-omissions? consch(at)earthlink.net
;
0,0,Warm engine-Running at idle-click on box for more info
0,1,Undefined Data
0,2,Undefined Data
0,3,Coolant temp sensor,less than 10,lower numbers are hotter
0,4,Undefined Data,
0,5,Heated OXS signal,Must vary by at least 14
0,6,Undefined Data
0,7,Undefined Data
0,8,Undefined Data
0,9,Undefined Data
0,10,Undefined Data
;
1,0,click on box for more info
1,1,Coolant Temp,,A constant -40 indicates an open circuit
1,2,Engine Speed,,775-825 at warm idle-Max 5500 governed
1,3,Oxygen Sensor,Output Voltage,Varies rapidly in range <.3 to >.7 volt
1,4,Fuel Injector,Duration,2-3 ms at warm idle - max 10 ms under load
;
2,0,click on box for more info
2,1,Coolant Temp,,A constant -40 indicates an open circuit
2,2,Engine Speed,,775-825 at warm idle-Max 5500 governed
2,3,Throttle Valve,Angle,0 at closed throttle to 85 at W.O.T -An open circuit will show a constan 0
2,4,Engine load,,20-40% at idle
;
3,0,click on box for more info
3,1,Coolant Temp,,A constant -40 indicates an open circuit
3,2,Engine Speed,,775-825 at warm idle-Max 5500 governed
3,3,Intake Air,Temperature,A constant -40 indicates an open circuit
3,4,ECM,Supply Voltage,should not exceed 14.5 Volts
;
4,0,click on box for more info
4,1,Coolant Temp,,A constant -40 indicates an open circuit
4,2,Engine Speed,,775-825 at warm idle-Max 5500 governed
4,3,Ignition Timeing,Calculated,This is the amount that is added to the base timeing which is adjusted by moveing the disributtor - see also mb 7 and 8
4,4,Engine load,,20-40% at idle
;
5,0,click on box for more info
5,1,Coolant Temp,,A constant -40 indicates an open circuit
5,2,Engine Speed,,775-825 at warm idle-Max 5500 governed
5,3,Throttle Valve,Angle,0 at closed throttle to 85 at W.O.T -An open circuit will show a constant 0
5,4,ECM,Supply Voltage,should not exceed 14.5 Volts
;
6,0,click on box for more info
6,1,Coolant Temp,,A constant -40 indicates an open circuit
6,2,Engine Speed,,775-825 at warm idle-Max 5500 governed
6,3,Undefined Data
6,4,Undefined Data
;
7,0,click on box for more info
7,1,Coolant Temp,,A constant -40 indicates an open circuit
7,2,Engine Speed,,775-825 at warm idle-Max 5500 governed
7,3,Ignition Timeing,Calculated,This displays as 131 002 xxx - as xxx decreases timeing advances
7,4,Undefined Data
;
8,0,click on box for more info
8,1,Coolant Temp,,A constant -40 indicates an open circuit
8,2,Engine Speed,,775-825 at warm idle-Max 5500 governed
8,3,Ignition Timeing,Calculated,observed range 40-0-255-240
8,4,Throttle Position,Click for translation,LEERLAUF=Closed throttle TEILLAST=part throttle VOLLAST=Wide open throttle
;
;eor
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -