⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 mpr dll.xml

📁 WJ Communications RFID example code
💻 XML
📖 第 1 页 / 共 5 页
字号:
            <summary>
            Determines whether the MPRFrameList contains a specific value.
            </summary>
            <param name="aFrame">The MPRFrame to locate in the MPRFrameList.</param>
            <returns>true if the MPRFrame is found in the MPRFrameList; otherwise, false.</returns>
        </member>
        <member name="P:WJ.MPR.Reader.MPRFrameList.Item(System.Int32)">
            <summary>
            Gets or sets the element at the specified index.
            This property is the indexer for the MPRFrameList class.
            </summary>
            <param name="Index">The zero-based index of the MPRFrame to get or set.</param>
            <value>The MPRFrame at the specified index.</value>
            <exception cref="T:System.ArgumentOutOfRangeException">index is not a valid index in the MPRFrameList.</exception>
        </member>
        <member name="T:WJ.MPR.Reader.CmdCode">
            <summary>
            Message Command Opcodes
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.CmdCode.unknown">
            <summary>
            Unknown Command.  Not a valid Command.
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.CmdCode.ReaderInfo">
            <summary>
            Requests the MPR Manufacturing Information
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.CmdCode.EnterBootloader">
            <summary>
            Exit Application and Launch Bootloader to Download a new FW Application.
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.CmdCode.Class0Read">
            <summary>
            Requests the Class 0 Inventory.
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.CmdCode.Class0Kill">
            <summary>
            Kill Class 0 Tags.
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.CmdCode.Class0ZumaCommands">
            <summary>
            Command to access Class0 Zuma subcommands.
            <see cref="T:WJ.MPR.Reader.Class0ZumaSubcommands"/>
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.CmdCode.Class0PlusLockPage">
            <summary>
            Lock a Class0+ (Matrics) ITM Page.
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.CmdCode.Class0PlusErasePage">
            <summary>
            Erase a Class0+ (Matrics) ITM Page.
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.CmdCode.Class0PlusRead">
            <summary>
            Read Class 0+ (Matrics) Tag Data.
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.CmdCode.Class0PlusWrite">
            <summary>
            Write Class 0+ (Matrics) Tag Data.
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.CmdCode.Class0PlusGlobalRead">
            <summary>
            Class 0+ (Matrics) global Read.
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.CmdCode.Class0PlusProgram">
            <summary>
            Program Class 0+ (Matrics) EPC.
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.CmdCode.Class1Read">
            <summary>
            Requests the Class 1 Inventory.
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.CmdCode.Class1Kill">
            <summary>
            Kill Class 1 Tags.
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.CmdCode.Class1Write">
            <summary>
            A Class1 Programming Command.
            Write 16 bits to a Class 1 Tag Data.
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.CmdCode.Class1IDVerify">
            <summary>
            A Class1 Programming Command.
            Verify a Class1 Tag.
            Reads and returns all data on tag, EPC and CRC.
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.CmdCode.Class1IDErase">
            <summary>
            A Class1 Programming Command.
            Erase Tags.
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.CmdCode.Class1ReadSingleTag">
            <summary>
            Attempt to read a Single Class1 Tag.
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.CmdCode.Class1ReadTagsWP">
            <summary>
            Request the Class 1 inventory using the Ping Algorithm.
            (Deprecated, please use Class1Read, 0x21)
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.CmdCode.Class1ProgramID">
            <summary>
            Integrated Class 1 Tag ID Program Command.
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.CmdCode.Gen2Command">
            <summary>
            All Gen2 commands use this opcode
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.CmdCode.GPIO">
            <summary>
            Set and Get the values of the GPIO pins
            </summary>
        </member>
        <member name="T:WJ.MPR.Reader.Class0ZumaSubcommands">
            <summary>
            These are the subcommands for Impinj Zuma (Re-writeable Class 0), command 0x18
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.Class0ZumaSubcommands.WriteRow">
            <summary>
            Write a Row (18 bits) to a Zuma Tag.
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.Class0ZumaSubcommands.ReadRow">
            <summary>
            Read a Row (18 bits) from a Zuma Tag.
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.Class0ZumaSubcommands.INIT">
            <summary>
            Initialize a Zuma Tag for re-writing.
            This RF-interface command sets the Fab Protect row to Golden Word.
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.Class0ZumaSubcommands.WriteAck">
            <summary>
            Write a Row (18 bits) to a Zuma Tag, and wait for an acknowledgement.
            Singulated-only command.
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.Class0ZumaSubcommands.ProgramEPC">
            <summary>
            Program an EPC, CRC and Kill Passcode into a Zuma Tag
            </summary>
        </member>
        <member name="T:WJ.MPR.Reader.Gen2Subcommands">
            <summary>
            These are the subcommands for Gen 2 Class 1, command 0x60
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.Gen2Subcommands.Inventory">
            <summary>
            
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.Gen2Subcommands.SelectAdd">
            <summary>
            
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.Gen2Subcommands.SelectRemove">
            <summary>
            
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.Gen2Subcommands.SelectRead">
            <summary>
            
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.Gen2Subcommands.Read">
            <summary>
            
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.Gen2Subcommands.Write">
            <summary>
            
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.Gen2Subcommands.Erase">
            <summary>
            
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.Gen2Subcommands.Lock">
            <summary>
            
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.Gen2Subcommands.Kill">
            <summary>
            
            </summary>
        </member>
        <member name="T:WJ.MPR.Reader.ZumaProgramOptions">
            <summary>
            These are the settings for the option parameter of
            the ZumaProgramEPC subcommand
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.ZumaProgramOptions.None">
            <summary>
            No options set
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.ZumaProgramOptions.CheckEPC">
            <summary>
            0b-------1	Ensure an invalid EPC and CRC before programming
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.ZumaProgramOptions.LockFP">
            <summary>
            0b------1-	Set (1) the Fab Protect Lock Bit during INIT
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.ZumaProgramOptions.LockEPC">
            <summary>
            0b-----1--	Lock the EPC, CRC and Control Word rows
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.ZumaProgramOptions.ProgramKill">
            <summary>
            0b----1---	Program the Kill Passcode
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.ZumaProgramOptions.LockKill">
            <summary>
            0b---1----	Lock the Kill Passcode
            </summary>
        </member>
        <member name="T:WJ.MPR.Reader.StatusCode">
            <summary>
            Command Response Status Codes.
            These are the Status bytes from Response Frames (or Packets).
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.StatusCode.Error">
            <summary>
            MPR reports an Error.
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.StatusCode.Complete">
            <summary>
            MPR complete the request.
            This is the last response frame.
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.StatusCode.InProgress">
            <summary>
            This is not the last response frame;
            More frames will follow.
            </summary>
        </member>
        <member name="F:WJ.MPR.Reader.StatusCode.unknown">
            <summary>
            Status Code could not be determined from a response frame.
            </summary>
        </member>
        <member name="T:WJ.MPR.Reader.ErrorCode">
            <summary>
            Command Response Error Codes.
            These Error Codes follow the Status Byte in Frames

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -