📄 rfc2837.txt
字号:
Error_Detect_Timeout Value is used as the timeout value for detecting an error condition." ::= { fcFxPortEntry 8 } -- FxPort class service parameters fcFxPortCosSupported OBJECT-TYPE SYNTAX FcCosCap MAX-ACCESS read-only STATUS current DESCRIPTION "A value indicating the set of Classes of Service supported by the FxPort." ::= { fcFxPortEntry 9 } fcFxPortIntermixSupported OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A flag indicating whether or not the FxPort supports an Intermixed Dedicated Connection." ::= { fcFxPortEntry 10 } fcFxPortStackedConnMode OBJECT-TYPE SYNTAX FcStackedConnMode MAX-ACCESS read-only STATUS current DESCRIPTION "A value indicating the mode of Stacked Connect supported by the FxPort."Teow Standards Track [Page 15]RFC 2837 FC Fabric Element MIB May 2000 ::= { fcFxPortEntry 11 } fcFxPortClass2SeqDeliv OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A flag indicating whether or not Class 2 Sequential Delivery is supported by the FxPort." ::= { fcFxPortEntry 12 } fcFxPortClass3SeqDeliv OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A flag indicating whether or not Class 3 Sequential Delivery is supported by the FxPort." ::= { fcFxPortEntry 13 } -- other FxPort parameters fcFxPortHoldTime OBJECT-TYPE SYNTAX MicroSeconds UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum time (in microseconds) that the FxPort shall hold a frame before discarding the frame if it is unable to deliver the frame. The value 0 means that the FxPort does not support this parameter." ::= { fcFxPortEntry 14 } -- the Status group -- This group consists of tables that contains operational -- status and established service parameters for the Fabric -- Element and the attached NxPorts. -- The FxPort Status table -- This table contains, one entry for each FxPort, -- the operational status and parameters of the FxPorts. fcFxPortStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFxPortStatusEntryTeow Standards Track [Page 16]RFC 2837 FC Fabric Element MIB May 2000 MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains, one entry for each FxPort in the Fabric Element, operational status and parameters of the FxPorts." ::= { fcFeStatus 1 } fcFxPortStatusEntry OBJECT-TYPE SYNTAX FcFxPortStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing operational status and parameters of a FxPort." AUGMENTS { fcFxPortEntry } ::= { fcFxPortStatusTable 1 } FcFxPortStatusEntry ::= SEQUENCE { fcFxPortID FcAddressId, fcFxPortBbCreditAvailable Gauge32, fcFxPortOperMode INTEGER, fcFxPortAdminMode INTEGER } fcFxPortID OBJECT-TYPE SYNTAX FcAddressId MAX-ACCESS read-only STATUS current DESCRIPTION "The address identifier by which this FxPort is identified within the Fabric. The FxPort may assign its address identifier to its attached NxPort(s) during Fabric Login." ::= { fcFxPortStatusEntry 1 } fcFxPortBbCreditAvailable OBJECT-TYPE SYNTAX Gauge32 UNITS "buffers" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of buffers currently available for receivingTeow Standards Track [Page 17]RFC 2837 FC Fabric Element MIB May 2000 frames from the attached port in the buffer-to-buffer flow control. The value should be less than or equal to fcFxPortBbCredit." ::= { fcFxPortStatusEntry 2 } fcFxPortOperMode OBJECT-TYPE SYNTAX INTEGER { unknown(1), fPort(2), flPort(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current operational mode of the FxPort." ::= { fcFxPortStatusEntry 3 } fcFxPortAdminMode OBJECT-TYPE SYNTAX INTEGER { fPort(2), flPort(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The desired operational mode of the FxPort." ::= { fcFxPortStatusEntry 4 } -- the FxPort Physical Level table -- This table contains, one entry for each FxPort in the -- Fabric Element, the physical level status and parameters -- of the FxPorts. fcFxPortPhysTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFxPortPhysEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains, one entry for each FxPort in the Fabric Element, physical level status and parameters of the FxPorts." ::= { fcFeStatus 2 } fcFxPortPhysEntry OBJECT-TYPE SYNTAX FcFxPortPhysEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing physical level status and parameters of a FxPort." AUGMENTS { fcFxPortEntry } ::= { fcFxPortPhysTable 1 } FcFxPortPhysEntry ::=Teow Standards Track [Page 18]RFC 2837 FC Fabric Element MIB May 2000 SEQUENCE { fcFxPortPhysAdminStatus INTEGER, fcFxPortPhysOperStatus INTEGER, fcFxPortPhysLastChange TimeStamp, fcFxPortPhysRttov MilliSeconds } fcFxPortPhysAdminStatus OBJECT-TYPE SYNTAX INTEGER { online (1), -- place port online offline (2), -- take port offline testing (3) -- initiate test procedures } MAX-ACCESS read-write STATUS current DESCRIPTION "The desired state of the FxPort. A management station may place the FxPort in a desired state by setting this object accordingly. The testing(3) state indicates that no operational frames can be passed. When a Fabric Element initializes, all FxPorts start with fcFxPortPhysAdminStatus in the offline(2) state. As the result of either explicit management action or per configuration information accessible by the Fabric Element, fcFxPortPhysAdminStatus is then changed to either the online(1) or testing(3) states, or remains in the offline state." ::= { fcFxPortPhysEntry 1 } fcFxPortPhysOperStatus OBJECT-TYPE SYNTAX INTEGER { online (1), -- Login may proceed offline (2), -- Login cannot proceed testing (3), -- port is under test linkFailure (4) -- failure after online/testing } MAX-ACCESS read-only STATUS current DESCRIPTION "The current operational status of the FxPort. The testing(3) indicates that no operational frames can be passed. If fcFxPortPhysAdminStatus is offline(2) then fcFxPortPhysOperStatus should be offline(2). If fcFxPortPhysAdminStatus is changed to online(1) then fcFxPortPhysOperStatus should change to online(1) if theTeow Standards Track [Page 19]RFC 2837 FC Fabric Element MIB May 2000 FxPort is ready to accept Fabric Login request from the attached NxPort; it should proceed and remain in the link- failure(4) state if and only if there is a fault that prevents it from going to the online(1) state." ::= { fcFxPortPhysEntry 2 } fcFxPortPhysLastChange OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime at the time the FxPort entered its current operational status. A value of zero indicates that the FxPort's operational status has not changed since the agent last restarted." ::= { fcFxPortPhysEntry 3 } fcFxPortPhysRttov OBJECT-TYPE SYNTAX MilliSeconds UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "The Receiver_Transmitter_Timeout value of the FxPort. This is used by the receiver logic to detect Loss of Synchronization." ::= { fcFxPortPhysEntry 4 } -- The FxPort Fabric Login table -- -- This table contains, one entry for each FxPort in the -- Fabric Element, the Service Parameters that have been -- established from the most recent Fabric Login, -- implicit or explicit. fcFxLoginTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFxLoginEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains, one entry for each NxPort attached to a particular FxPort in the Fabric Element, services parameters established from the most recent Fabric Login, explicit or implicit. Note that an FxPort may have one or more NxPort attached to it." ::= { fcFeStatus 3 }Teow Standards Track [Page 20]RFC 2837 FC Fabric Element MIB May 2000 fcFxLoginEntry OBJECT-TYPE SYNTAX FcFxLoginEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing service parameters established from a successful Fabric Login." INDEX { fcFeModuleIndex, fcFxPortIndex, fcFxPortNxLoginIndex } ::= { fcFxLoginTable 1 } FcFxLoginEntry ::= SEQUENCE { fcFxPortNxLoginIndex FcFeNxPortIndex, fcFxPortFcphVersionAgreed FcphVersion, fcFxPortNxPortBbCredit FcBbCredit, fcFxPortNxPortRxDataFieldSize FcRxDataFieldSize, fcFxPortCosSuppAgreed FcCosCap, fcFxPortIntermixSuppAgreed TruthValue, fcFxPortStackedConnModeAgreed FcStackedConnMode, fcFxPortClass2SeqDelivAgreed TruthValue, fcFxPortClass3SeqDelivAgreed TruthValue, -- fcFxPortNxPortName FcNameId, fcFxPortConnectedNxPort FcAddressId, fcFxPortBbCreditModel FcBbCreditModel } fcFxPortNxLoginIndex OBJECT-TYPE SYNTAX FcFeNxPortIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "The object identifies the associated NxPort in the attachment for which the entry contains information." ::= { fcFxLoginEntry 1 }Teow Standards Track [Page 21]RFC 2837 FC Fabric Element MIB May 2000 fcFxPortFcphVersionAgreed OBJECT-TYPE SYNTAX FcphVersion MAX-ACCESS read-only STATUS current DESCRIPTION "The version of FC-PH that the FxPort has agreed to support from the Fabric Login" ::= { fcFxLoginEntry 2 } fcFxPortNxPortBbCredit OBJECT-TYPE SYNTAX FcBbCredit UNITS "buffers" MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of buffers available for holding Class 1 connect-request, Class 2 or Class 3 frames to be transmitted to the attached NxPort. It is for buffer-to- buffer flow control in the direction from FxPort to NxPort. The buffer-to-buffer flow control mechanism is indicated in the respective fcFxPortBbCreditModel." ::= { fcFxLoginEntry 3 } fcFxPortNxPortRxDataFieldSize OBJECT-TYPE SYNTAX FcRxDataFieldSize UNITS "bytes" MAX-ACCESS read-only
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -