⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc2837.txt

📁 著名的RFC文档,其中有一些文档是已经翻译成中文的的.
💻 TXT
📖 第 1 页 / 共 5 页
字号:
          Error_Detect_Timeout Value is used as the timeout value for          detecting an error condition."  ::= { fcFxPortEntry 8 }  -- FxPort class service parameters  fcFxPortCosSupported OBJECT-TYPE      SYNTAX      FcCosCap      MAX-ACCESS  read-only      STATUS      current      DESCRIPTION         "A value indicating the set of Classes of Service supported          by the FxPort."  ::= { fcFxPortEntry 9 }  fcFxPortIntermixSupported OBJECT-TYPE      SYNTAX      TruthValue      MAX-ACCESS  read-only      STATUS      current      DESCRIPTION         "A flag indicating whether or not the FxPort supports an          Intermixed Dedicated Connection."  ::= { fcFxPortEntry 10 }  fcFxPortStackedConnMode OBJECT-TYPE      SYNTAX      FcStackedConnMode      MAX-ACCESS  read-only      STATUS      current      DESCRIPTION         "A value indicating the mode of Stacked Connect supported by          the FxPort."Teow                        Standards Track                    [Page 15]RFC 2837                 FC Fabric Element MIB                  May 2000  ::= { fcFxPortEntry 11 }  fcFxPortClass2SeqDeliv OBJECT-TYPE      SYNTAX      TruthValue      MAX-ACCESS  read-only      STATUS      current      DESCRIPTION         "A flag indicating whether or not Class 2 Sequential          Delivery is supported by the FxPort."  ::= { fcFxPortEntry 12 }  fcFxPortClass3SeqDeliv OBJECT-TYPE      SYNTAX      TruthValue      MAX-ACCESS  read-only      STATUS      current      DESCRIPTION         "A flag indicating whether or not Class 3 Sequential          Delivery is supported by the FxPort."  ::= { fcFxPortEntry 13 }  -- other FxPort parameters  fcFxPortHoldTime OBJECT-TYPE      SYNTAX      MicroSeconds      UNITS       "microseconds"      MAX-ACCESS  read-only      STATUS      current      DESCRIPTION         "The maximum time (in microseconds) that the FxPort shall          hold a frame before discarding the frame if it is unable to          deliver the frame. The value 0 means that the FxPort does          not support this parameter."  ::= { fcFxPortEntry 14 }  -- the Status group  -- This group consists of tables that contains operational  -- status and established service parameters for the Fabric  -- Element and the attached NxPorts.  -- The FxPort Status table  -- This table contains, one entry for each FxPort,  -- the operational status and parameters of the FxPorts.  fcFxPortStatusTable OBJECT-TYPE      SYNTAX      SEQUENCE OF FcFxPortStatusEntryTeow                        Standards Track                    [Page 16]RFC 2837                 FC Fabric Element MIB                  May 2000      MAX-ACCESS  not-accessible      STATUS      current      DESCRIPTION         "A table that contains, one entry for each FxPort in the          Fabric Element, operational status and parameters of the          FxPorts."  ::= { fcFeStatus 1 }  fcFxPortStatusEntry OBJECT-TYPE      SYNTAX      FcFxPortStatusEntry      MAX-ACCESS  not-accessible      STATUS      current      DESCRIPTION         "An entry containing operational status and parameters of a          FxPort."      AUGMENTS { fcFxPortEntry }  ::= { fcFxPortStatusTable 1 }  FcFxPortStatusEntry ::=      SEQUENCE {          fcFxPortID              FcAddressId,          fcFxPortBbCreditAvailable              Gauge32,          fcFxPortOperMode              INTEGER,          fcFxPortAdminMode              INTEGER      }  fcFxPortID   OBJECT-TYPE      SYNTAX      FcAddressId      MAX-ACCESS  read-only      STATUS      current      DESCRIPTION         "The address identifier by which this FxPort is identified          within the Fabric.  The FxPort may assign its address          identifier to its attached NxPort(s) during Fabric Login."  ::= { fcFxPortStatusEntry 1 }  fcFxPortBbCreditAvailable OBJECT-TYPE      SYNTAX      Gauge32      UNITS       "buffers"      MAX-ACCESS  read-only      STATUS      current      DESCRIPTION         "The number of buffers currently available for receivingTeow                        Standards Track                    [Page 17]RFC 2837                 FC Fabric Element MIB                  May 2000          frames from the attached port in the buffer-to-buffer flow          control. The value should be less than or equal to          fcFxPortBbCredit."  ::= { fcFxPortStatusEntry 2 }  fcFxPortOperMode    OBJECT-TYPE      SYNTAX              INTEGER { unknown(1), fPort(2), flPort(3) }      MAX-ACCESS          read-only      STATUS              current      DESCRIPTION         "The current operational mode of the FxPort."  ::= { fcFxPortStatusEntry 3 }  fcFxPortAdminMode   OBJECT-TYPE      SYNTAX              INTEGER { fPort(2), flPort(3) }      MAX-ACCESS          read-write      STATUS              current      DESCRIPTION         "The desired operational mode of the FxPort."  ::= { fcFxPortStatusEntry 4 }  -- the FxPort Physical Level table  -- This table contains, one entry for each FxPort in the  -- Fabric Element, the physical level status and parameters  -- of the FxPorts.  fcFxPortPhysTable OBJECT-TYPE      SYNTAX      SEQUENCE OF FcFxPortPhysEntry      MAX-ACCESS  not-accessible      STATUS      current      DESCRIPTION         "A table that contains, one entry for each FxPort in the          Fabric Element, physical level status and parameters of the          FxPorts."  ::= { fcFeStatus 2 }  fcFxPortPhysEntry OBJECT-TYPE      SYNTAX      FcFxPortPhysEntry      MAX-ACCESS  not-accessible      STATUS      current      DESCRIPTION         "An entry containing physical level status and parameters of          a FxPort."      AUGMENTS { fcFxPortEntry }  ::= { fcFxPortPhysTable 1 }  FcFxPortPhysEntry ::=Teow                        Standards Track                    [Page 18]RFC 2837                 FC Fabric Element MIB                  May 2000      SEQUENCE {          fcFxPortPhysAdminStatus              INTEGER,          fcFxPortPhysOperStatus              INTEGER,          fcFxPortPhysLastChange              TimeStamp,          fcFxPortPhysRttov              MilliSeconds      }  fcFxPortPhysAdminStatus OBJECT-TYPE      SYNTAX      INTEGER {                      online  (1),  -- place port online                      offline (2),  -- take port offline                      testing (3)   -- initiate test procedures                  }      MAX-ACCESS  read-write      STATUS      current      DESCRIPTION         "The desired state of the FxPort.  A management station may          place the FxPort in a desired state by setting this object          accordingly.  The testing(3) state indicates that no          operational frames can be passed.  When a Fabric Element          initializes, all FxPorts start with fcFxPortPhysAdminStatus          in the offline(2) state.  As the result of either explicit          management action or per configuration information          accessible by the Fabric Element, fcFxPortPhysAdminStatus          is then changed to either the online(1) or testing(3)          states, or remains in the offline state."  ::= { fcFxPortPhysEntry 1 }  fcFxPortPhysOperStatus   OBJECT-TYPE      SYNTAX      INTEGER {          online       (1), -- Login may proceed          offline      (2), -- Login cannot proceed          testing      (3), -- port is under test          linkFailure  (4)  -- failure after online/testing      }      MAX-ACCESS  read-only      STATUS      current      DESCRIPTION         "The current operational status of the FxPort.  The          testing(3) indicates that no operational frames can be          passed.  If fcFxPortPhysAdminStatus is offline(2) then          fcFxPortPhysOperStatus should be offline(2). If          fcFxPortPhysAdminStatus is changed to online(1) then          fcFxPortPhysOperStatus should change to online(1) if theTeow                        Standards Track                    [Page 19]RFC 2837                 FC Fabric Element MIB                  May 2000          FxPort is ready to accept Fabric Login request from the          attached NxPort; it should proceed and remain in the link-          failure(4) state if and only if there is a fault that          prevents it from going to the online(1) state."  ::= { fcFxPortPhysEntry 2 }  fcFxPortPhysLastChange OBJECT-TYPE      SYNTAX      TimeStamp      MAX-ACCESS  read-only      STATUS      current      DESCRIPTION         "The value of sysUpTime at the time the FxPort entered its          current operational status. A value of zero indicates that          the FxPort's operational status has not changed since the          agent last restarted."  ::= { fcFxPortPhysEntry 3 }  fcFxPortPhysRttov OBJECT-TYPE      SYNTAX      MilliSeconds      UNITS       "milliseconds"      MAX-ACCESS  read-write      STATUS      current      DESCRIPTION         "The Receiver_Transmitter_Timeout value of the FxPort. This          is used by the receiver logic to detect Loss of          Synchronization."  ::= { fcFxPortPhysEntry 4 }  -- The FxPort Fabric Login table  --  -- This table contains, one entry for each FxPort in the  -- Fabric Element, the Service Parameters that have been  -- established from the most recent Fabric Login,  -- implicit or explicit.  fcFxLoginTable OBJECT-TYPE      SYNTAX      SEQUENCE OF FcFxLoginEntry      MAX-ACCESS  not-accessible      STATUS      current      DESCRIPTION         "A table that contains, one entry for each NxPort attached          to a particular FxPort in the Fabric Element, services          parameters established from the most recent Fabric Login,          explicit or implicit. Note that an FxPort may have one or          more NxPort attached to it."  ::= { fcFeStatus 3 }Teow                        Standards Track                    [Page 20]RFC 2837                 FC Fabric Element MIB                  May 2000  fcFxLoginEntry OBJECT-TYPE      SYNTAX      FcFxLoginEntry      MAX-ACCESS  not-accessible      STATUS      current      DESCRIPTION         "An entry containing service parameters established from a          successful Fabric Login."      INDEX { fcFeModuleIndex, fcFxPortIndex, fcFxPortNxLoginIndex }  ::= { fcFxLoginTable 1 }  FcFxLoginEntry ::=      SEQUENCE {          fcFxPortNxLoginIndex              FcFeNxPortIndex,          fcFxPortFcphVersionAgreed              FcphVersion,          fcFxPortNxPortBbCredit              FcBbCredit,          fcFxPortNxPortRxDataFieldSize              FcRxDataFieldSize,          fcFxPortCosSuppAgreed              FcCosCap,          fcFxPortIntermixSuppAgreed              TruthValue,          fcFxPortStackedConnModeAgreed              FcStackedConnMode,          fcFxPortClass2SeqDelivAgreed              TruthValue,          fcFxPortClass3SeqDelivAgreed              TruthValue,          --          fcFxPortNxPortName              FcNameId,          fcFxPortConnectedNxPort              FcAddressId,          fcFxPortBbCreditModel              FcBbCreditModel      }  fcFxPortNxLoginIndex OBJECT-TYPE      SYNTAX      FcFeNxPortIndex      MAX-ACCESS  not-accessible      STATUS      current      DESCRIPTION         "The object identifies the associated NxPort in the          attachment for which the entry contains information."  ::= { fcFxLoginEntry 1 }Teow                        Standards Track                    [Page 21]RFC 2837                 FC Fabric Element MIB                  May 2000  fcFxPortFcphVersionAgreed OBJECT-TYPE      SYNTAX      FcphVersion      MAX-ACCESS  read-only      STATUS      current      DESCRIPTION         "The version of FC-PH that the FxPort has agreed to support          from the Fabric Login"  ::= { fcFxLoginEntry 2 }  fcFxPortNxPortBbCredit OBJECT-TYPE      SYNTAX      FcBbCredit      UNITS       "buffers"      MAX-ACCESS  read-only      STATUS      current      DESCRIPTION         "The total number of buffers available for holding Class 1          connect-request, Class 2 or Class 3 frames to be          transmitted to the attached NxPort.  It is for buffer-to-          buffer flow control in the direction from FxPort to NxPort.          The buffer-to-buffer flow control mechanism is indicated in          the respective fcFxPortBbCreditModel."  ::= { fcFxLoginEntry 3 }  fcFxPortNxPortRxDataFieldSize OBJECT-TYPE      SYNTAX      FcRxDataFieldSize      UNITS       "bytes"      MAX-ACCESS  read-only

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -