📄 rfc2954.txt
字号:
MAX-ACCESS read-onlyRehbehn & Fowler Standards Track [Page 18]RFC 2954 Frame Relay Service MIB October 2000 STATUS current DESCRIPTION "The value of this object identifies the type of network interface for this logical port." ::= { frLportEntry 4 } frLportAddrDLCILen OBJECT-TYPE SYNTAX INTEGER { twoOctets10Bits(1), threeOctets10Bits(2), threeOctets16Bits(3), fourOctets17Bits(4), fourOctets23Bits(5) } UNITS "Octets" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the Q.922 Address field length and DLCI length for this UNI/NNI logical port." REFERENCE "Q.922 [25]" ::= { frLportEntry 5 } frLportVCSigProtocol OBJECT-TYPE SYNTAX INTEGER { none(1), lmi(2), ansiT1617D(3), ansiT1617B(4), ccittQ933A(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the Local In-Channel Signaling Protocol that is used for this frame relay UNI/NNI logical port. none(1): Interface does not use a PVC signaling protocol lmi(2): Interface operates the Stratacom/ Nortel/DEC Local Management Interface Specification protocol ansiT1617D(3): Interface operates the ANSI T1.617 Annex D PVC status protocolRehbehn & Fowler Standards Track [Page 19]RFC 2954 Frame Relay Service MIB October 2000 ansiT1617B(4): Interface operates the ANSIT1.617 Annex B procedures ccittQ933A(5): Interface operates the ITU Q.933 Annex A PVC status protocol" REFERENCE "LMI [24] T1.617 Annex D [17], Q.933 Annex A [22]" ::= { frLportEntry 6 } frLportVCSigPointer OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The value of this object is used as a pointer to the table that contains the Local In-Channel Signaling Protocol parameters and errors for this UNI/NNI logical port. This object has been deprecated to reflect the fact that the local in-channel signaling parameters are accessed from a single table (frMgtVCSigTable) that includes parameters for all possible signaling protocols. Early design anticipated multiple tables, one for each signaling protocol." ::= { frLportEntry 7 } frLportDLCIIndexValue OBJECT-TYPE SYNTAX Integer32 (16..4194303) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains a hint to be used for frPVCEndptDLCIIndex when creating entries in the frPVCEndptTable. The SYNTAX of this object matches the SYNTAX of the frPVCEndptDLCIIndex - an object that is restricted to legal Q.922 DLCI values for the size of the address field. The value 0 indicates that no unassigned entries are available. To obtain the frPVCEndptDLCIIndex value for a new entry, the manager issues a management protocol retrieval operation to obtain the current value ofRehbehn & Fowler Standards Track [Page 20]RFC 2954 Frame Relay Service MIB October 2000 this object. After each retrieval, the agent must modify the value to the next unassigned index to prevent assignment of the same value to multiple management systems. A management system should repeat the read to obtain a new value should an attempt to create the new row using the previously returned hint fail." REFERENCE "Q.922 [25]" ::= { frLportEntry 8 } frLportTypeAdmin OBJECT-TYPE SYNTAX INTEGER { uni(1), nni(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this object desired identifies the type of network interface for this logical port." ::= { frLportEntry 9 } frLportVCSigProtocolAdmin OBJECT-TYPE SYNTAX INTEGER { none(1), lmi(2), ansiT1617D(3), ansiT1617B(4), ccittQ933A(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this object identifies the desired Local In-Channel Signaling Protocol that is used for this frame relay UNI/NNI logical port. This value must be made the active protocol as soon as possible on the device. Refer to frLportVCSigProtocol for a description of each signaling protocol choices." REFERENCE "LMI [24] T1.617 Annex D [17], Q.933 Annex A [22]" ::= { frLportEntry 10 } frLportFragControl OBJECT-TYPERehbehn & Fowler Standards Track [Page 21]RFC 2954 Frame Relay Service MIB October 2000 SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object controls the transmission and reception of fragmentation frames for this UNI or NNI interface. on(1) Frames are fragmented using the interface fragmentation format Note: The customer side of the interface must also be configured to fragment frames. off(2) Frames are not fragmented using the interface fragmentation format." REFERENCE "FRF.12 [21]" DEFVAL { off } ::= { frLportEntry 11 } frLportFragSize OBJECT-TYPE SYNTAX Integer32 (0..4096) UNITS "Octets" MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this object is the size in octets of the maximum size of each fragment to be sent when fragmenting. This object is only used by the fragmentation transmitter, and the two sides of the interface may differ. The fragment size includes the octets for the frame relay header, the UI octet, the NLPID, the fragmentation header, and the fragment payload. If frLportFragControl is set to off, this value should be zero." REFERENCE "FRF.12 [21]" DEFVAL { 0 } ::= { frLportEntry 12 } -- -- Frame Relay Management VC Signaling -- frMgtVCSigTable OBJECT-TYPE SYNTAX SEQUENCE OF FrMgtVCSigEntryRehbehn & Fowler Standards Track [Page 22]RFC 2954 Frame Relay Service MIB October 2000 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Frame Relay Management VC Signaling Parameters and Errors table." ::= { frnetservObjects 2 } frMgtVCSigEntry OBJECT-TYPE SYNTAX FrMgtVCSigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Frame Relay Management VC Signaling Parameters Errors table." INDEX { ifIndex } ::= { frMgtVCSigTable 1 } FrMgtVCSigEntry ::= SEQUENCE { frMgtVCSigProced INTEGER, frMgtVCSigUserN391 INTEGER, frMgtVCSigUserN392 INTEGER, frMgtVCSigUserN393 INTEGER, frMgtVCSigUserT391 INTEGER, frMgtVCSigNetN392 INTEGER, frMgtVCSigNetN393 INTEGER, frMgtVCSigNetT392 INTEGER, frMgtVCSigNetnN4 INTEGER, frMgtVCSigNetnT3 INTEGER, frMgtVCSigUserLinkRelErrors Counter32, frMgtVCSigUserProtErrors Counter32, frMgtVCSigUserChanInactive Counter32, frMgtVCSigNetLinkRelErrors Counter32, frMgtVCSigNetProtErrors Counter32, frMgtVCSigNetChanInactive Counter32, frMgtVCSigProcedAdmin INTEGER, frMgtVCSigUserN391Admin INTEGER, frMgtVCSigUserN392Admin INTEGER, frMgtVCSigUserN393Admin INTEGER, frMgtVCSigUserT391Admin INTEGER, frMgtVCSigNetN392Admin INTEGER, frMgtVCSigNetN393Admin INTEGER, frMgtVCSigNetT392Admin INTEGER, frMgtVCSigNetnT3Admin INTEGER } frMgtVCSigProced OBJECT-TYPE SYNTAX INTEGER {Rehbehn & Fowler Standards Track [Page 23]RFC 2954 Frame Relay Service MIB October 2000 u2nnet(1), bidirect(2), u2nuser(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the local in-channel signaling procedural role that is used for this UNI/NNI logical port. Bidirectional procedures implies that both user-side and network-side procedural roles are used. u2nnet(1) Logical port operates user to network procedure in the role of the network side bidirect(2) Logical port operates the bidirectional procedure (both user and network side roles) u2nuser(3) Logical port operates user to network procedure in the role of the user side" REFERENCE "Q.933 Annex A [22], T1.617 Annex D [17]" ::= { frMgtVCSigEntry 1 } frMgtVCSigUserN391 OBJECT-TYPE SYNTAX INTEGER (1..255) UNITS "Polls" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the User-side N391 full status polling cycle value for this UNI/NNI logical port. If the logical port is not performing user-side (bidirectional) procedures, then this object is not instantiated and an attempt to read will result in the noSuchInstance exception response." REFERENCE "Q.933 Annex A [22], T1.617 Annex D [17]" DEFVAL { 6 } ::= { frMgtVCSigEntry 2 }
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -