📄 rfc1315.txt
字号:
DEFVAL { 10 } ::= { frDlcmiEntry 5 } frDlcmiFullEnquiryInterval OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Number of status enquiry intervals that pass before issuance of a full status enquiry mes- sage." REFERENCE "Draft American National Standard T1.617-1991, Section D.7 Counter N391." DEFVAL { 6 } ::= { frDlcmiEntry 6 } frDlcmiErrorThreshold OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-write STATUS mandatory DESCRIPTION "This is the maximum number of unanswered Status Enquiries the equipment shall accept be- fore declaring the interface down." REFERENCE "Draft American National Standard T1.617-1991, Section D.5.1 Counter N392." DEFVAL { 3 } ::= { frDlcmiEntry 7 }Brown, Baker & Carvalho [Page 7]RFC 1315 Frame Relay DTE MIB April 1992 frDlcmiMonitoredEvents OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-write STATUS mandatory DESCRIPTION "This is the number of status polling intervals over which the error threshold is counted. For example, if within 'MonitoredEvents' number of events the station receives 'ErrorThreshold' number of errors, the interface is marked as down." REFERENCE "Draft American National Standard T1.617-1991, Section D.5.2 Counter N393." DEFVAL { 4 } ::= { frDlcmiEntry 8 } frDlcmiMaxSupportedVCs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of Virtual Circuits allowed for this interface. Usually dictated by the Frame Relay network. In response to a SET, if a value less than zero or higher than the agent's maximal capability is configured, the agent should respond bad- Value" ::= { frDlcmiEntry 9 } frDlcmiMulticast OBJECT-TYPE SYNTAX INTEGER { nonBroadcast (1), broadcast (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This indicates whether the Frame Relay inter- face is using a multicast service." ::= { frDlcmiEntry 10 }Brown, Baker & Carvalho [Page 8]RFC 1315 Frame Relay DTE MIB April 1992 -- A Frame Relay service is a multiplexing service. Data -- Link Connection Identifiers enumerate virtual circuits -- (permanent or dynamic) which are layered onto the underlying -- circuit, represented by ifEntry. Therefore, each of the entries -- in the Standard MIB's Interface Table with an IfType of -- Frame Relay represents a Q.922 interface. Zero or more -- virtual circuits are layered onto this interface and provide -- interconnection with various remote destinations. -- Each such virtual circuit is represented by an entry in the -- circuit table. -- Circuit Table -- The table describing the use of the DLCIs attached to -- each Frame Relay Interface. frCircuitTable OBJECT-TYPE SYNTAX SEQUENCE OF FrCircuitEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing information about specific Data Link Connection Identifiers and corresponding virtual circuits." ::= { frame-relay 2 } frCircuitEntry OBJECT-TYPE SYNTAX FrCircuitEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The information regarding a single Data Link Connection Identifier." INDEX { frCircuitIfIndex, frCircuitDlci } ::= { frCircuitTable 1 } FrCircuitEntry ::= SEQUENCE { frCircuitIfIndex Index, frCircuitDlci DLCI, frCircuitState INTEGER, frCircuitReceivedFECNs Counter, frCircuitReceivedBECNsBrown, Baker & Carvalho [Page 9]RFC 1315 Frame Relay DTE MIB April 1992 Counter, frCircuitSentFrames Counter, frCircuitSentOctets Counter, frCircuitReceivedFrames Counter, frCircuitReceivedOctets Counter, frCircuitCreationTime TimeTicks, frCircuitLastTimeChange TimeTicks, frCircuitCommittedBurst INTEGER, frCircuitExcessBurst INTEGER, frCircuitThroughput INTEGER } frCircuitIfIndex OBJECT-TYPE SYNTAX Index ACCESS read-only STATUS mandatory DESCRIPTION "The ifIndex Value of the ifEntry this virtual circuit is layered onto." ::= { frCircuitEntry 1 } frCircuitDlci OBJECT-TYPE SYNTAX DLCI ACCESS read-only STATUS mandatory DESCRIPTION "The Data Link Connection Identifier for this virtual circuit." REFERENCE "Draft American National Standard T1.618-1991, Section 3.3.6" ::= { frCircuitEntry 2 }Brown, Baker & Carvalho [Page 10]RFC 1315 Frame Relay DTE MIB April 1992 frCircuitState OBJECT-TYPE SYNTAX INTEGER { invalid (1), active (2), inactive (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether the particular virtual cir- cuit is operational. In the absence of a Data Link Connection Management Interface, virtual circuit entries (rows) may be created by set- ting virtual circuit state to 'active', or deleted by changing Circuit state to 'invalid'. Whether or not the row actually disappears is left to the implementation, so this object may actually read as 'invalid' for some arbitrary length of time. It is also legal to set the state of a virtual circuit to 'inactive' to temporarily disable a given circuit." DEFVAL { active } ::= { frCircuitEntry 3 } frCircuitReceivedFECNs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received from the network in- dicating forward congestion since the virtual circuit was created." REFERENCE "Draft American National Standard T1.618-1991, Section 3.3.3" ::= { frCircuitEntry 4 } frCircuitReceivedBECNs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received from the network in- dicating backward congestion since the virtual circuit was created."Brown, Baker & Carvalho [Page 11]RFC 1315 Frame Relay DTE MIB April 1992 REFERENCE "Draft American National Standard T1.618-1991, Section 3.3.4" ::= { frCircuitEntry 5 } frCircuitSentFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames sent from this virtual circuit since it was created." ::= { frCircuitEntry 6 } frCircuitSentOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of octets sent from this virtual circuit since it was created." ::= { frCircuitEntry 7 } frCircuitReceivedFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received over this virtual circuit since it was created." ::= { frCircuitEntry 8 } frCircuitReceivedOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of octets received over this virtual circuit since it was created." ::= { frCircuitEntry 9 }Brown, Baker & Carvalho [Page 12]RFC 1315 Frame Relay DTE MIB April 1992 frCircuitCreationTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime when the virtual cir- cuit was created, whether by the Data Link Con- nection Management Interface or by a SetRe- quest." ::= { frCircuitEntry 10 } frCircuitLastTimeChange OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime when last there was a change in the virtual circuit state" ::= { frCircuitEntry 11 } frCircuitCommittedBurst OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This variable indicates the maximum amount of data, in bits, that the network agrees to transfer under normal conditions, during the measurement interval." REFERENCE
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -