rfc1743.txt

来自「著名的RFC文档,其中有一些文档是已经翻译成中文的的.」· 文本 代码 · 共 1,404 行 · 第 1/3 页

TXT
1,404
字号
                    false(2)                }    MAX-ACCESS  read-write    STATUS      current    DESCRIPTION            "If this object has a value of true(1) then            this interface will participate in the            active monitor selection process.  If the            value is false(2) then it will not.            Setting this object does not take effect            until the next Active Monitor election, and            might not take effect until the next time            the interface is opened."    ::= { dot5Entry 8 }dot5Functional  OBJECT-TYPE    SYNTAX      MacAddress    MAX-ACCESS  read-write    STATUS      current    DESCRIPTION            "The bit mask of all Token Ring functional            addresses for which this interface will            accept frames."    ::= { dot5Entry 9 }dot5LastBeaconSent OBJECT-TYPE    SYNTAX      TimeStamp    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "The value of MIB-II's sysUpTime object at which            the local system last transmitted a Beacon frame            on this interface."    ::= { dot5Entry 10 }McCloghrie & Decker                                             [Page 9]RFC 1743               IEEE 802.5 MIB using SMIv2          December 1994--   The 802.5 Statistics Table-- This table contains statistics and error counter which are-- specific to 802.5 interfaces.  It is mandatory that systems-- having 802.5 interfaces implement this table.dot5StatsTable  OBJECT-TYPE    SYNTAX      SEQUENCE OF Dot5StatsEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION            "A table containing Token Ring statistics,            one entry per 802.5 interface.                All the statistics are defined using            the syntax Counter32 as 32-bit wrap around            counters.  Thus, if an interface's            hardware maintains these statistics in            16-bit counters, then the agent must read            the hardware's counters frequently enough            to prevent loss of significance, in order            to maintain 32-bit counters in software."    ::= { dot5 2 }dot5StatsEntry  OBJECT-TYPE    SYNTAX      Dot5StatsEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION            "An entry contains the 802.5 statistics             for a particular interface."    INDEX       { dot5StatsIfIndex }    ::= { dot5StatsTable 1 }Dot5StatsEntry ::= SEQUENCE {     dot5StatsIfIndex              Integer32,     dot5StatsLineErrors           Counter32,     dot5StatsBurstErrors          Counter32,     dot5StatsACErrors             Counter32,     dot5StatsAbortTransErrors     Counter32,     dot5StatsInternalErrors       Counter32,     dot5StatsLostFrameErrors      Counter32,     dot5StatsReceiveCongestions   Counter32,     dot5StatsFrameCopiedErrors    Counter32,     dot5StatsTokenErrors          Counter32,     dot5StatsSoftErrors           Counter32,     dot5StatsHardErrors           Counter32,     dot5StatsSignalLoss           Counter32,McCloghrie & Decker                                            [Page 10]RFC 1743               IEEE 802.5 MIB using SMIv2          December 1994     dot5StatsTransmitBeacons      Counter32,     dot5StatsRecoverys            Counter32,     dot5StatsLobeWires            Counter32,     dot5StatsRemoves              Counter32,     dot5StatsSingles              Counter32,     dot5StatsFreqErrors           Counter32}dot5StatsIfIndex  OBJECT-TYPE    SYNTAX      Integer32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "The value of this object identifies the            802.5 interface for which this entry            contains management information.  The            value of this object for a particular            interface has the same value as MIB-II's            ifIndex object for the same interface."    ::= { dot5StatsEntry 1 }dot5StatsLineErrors OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "This counter is incremented when a frame            or token is copied or repeated by a            station, the E bit is zero in the frame            or token and one of the following            conditions exists: 1) there is a            non-data bit (J or K bit) between the SD            and the ED of the frame or token, or            2) there is an FCS error in the frame."    ::= { dot5StatsEntry 2 }dot5StatsBurstErrors OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "This counter is incremented when a station            detects the absence of transitions for five            half-bit timers (burst-five error)."    ::= { dot5StatsEntry 3 }McCloghrie & Decker                                            [Page 11]RFC 1743               IEEE 802.5 MIB using SMIv2          December 1994dot5StatsACErrors OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "This counter is incremented when a station            receives an AMP or SMP frame in which A is            equal to C is equal to 0, and then receives            another SMP frame with A is equal to C is            equal to 0 without first receiving an AMP            frame. It denotes a station that cannot set            the AC bits properly."    ::= { dot5StatsEntry 4 }dot5StatsAbortTransErrors OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "This counter is incremented when a station            transmits an abort delimiter while            transmitting."    ::= { dot5StatsEntry 5 }dot5StatsInternalErrors OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "This counter is incremented when a station            recognizes an internal error."    ::= { dot5StatsEntry 6 }dot5StatsLostFrameErrors OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "This counter is incremented when a station            is transmitting and its TRR timer expires.            This condition denotes a condition where a            transmitting station in strip mode does not            receive the trailer of the frame before the            TRR timer goes off."    ::= { dot5StatsEntry 7 }McCloghrie & Decker                                            [Page 12]RFC 1743               IEEE 802.5 MIB using SMIv2          December 1994dot5StatsReceiveCongestions OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "This counter is incremented when a station            recognizes a frame addressed to its            specific address, but has no available            buffer space indicating that the station            is congested."    ::= { dot5StatsEntry 8 }dot5StatsFrameCopiedErrors OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "This counter is incremented when a station            recognizes a frame addressed to its            specific address and detects that the FS            field A bits are set to 1 indicating a            possible line hit or duplicate address."    ::= { dot5StatsEntry 9 }dot5StatsTokenErrors OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "This counter is incremented when a station            acting as the active monitor recognizes an            error condition that needs a token            transmitted."    ::= { dot5StatsEntry 10 }dot5StatsSoftErrors OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "The number of Soft Errors the interface            has detected. It directly corresponds to            the number of Report Error MAC frames            that this interface has transmitted.            Soft Errors are those which are            recoverable by the MAC layer protocols."    ::= { dot5StatsEntry 11 }McCloghrie & Decker                                            [Page 13]RFC 1743               IEEE 802.5 MIB using SMIv2          December 1994dot5StatsHardErrors OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "The number of times this interface has            detected an immediately recoverable            fatal error.  It denotes the number of            times this interface is either            transmitting or receiving beacon MAC            frames."    ::= { dot5StatsEntry 12 }dot5StatsSignalLoss OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "The number of times this interface has            detected the loss of signal condition from            the ring."    ::= { dot5StatsEntry 13 }dot5StatsTransmitBeacons OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "The number of times this interface has            transmitted a beacon frame."    ::= { dot5StatsEntry 14 }dot5StatsRecoverys OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "The number of Claim Token MAC frames            received or transmitted after the interface            has received a Ring Purge MAC frame.  This            counter signifies the number of times the            ring has been purged and is being recovered            back into a normal operating state."    ::= { dot5StatsEntry 15 }dot5StatsLobeWires OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-onlyMcCloghrie & Decker                                            [Page 14]RFC 1743               IEEE 802.5 MIB using SMIv2          December 1994    STATUS      current    DESCRIPTION            "The number of times the interface has            detected an open or short circuit in the            lobe data path.  The adapter will be closed            and dot5RingState will signify this            condition."    ::= { dot5StatsEntry 16 }dot5StatsRemoves OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "The number of times the interface has            received a Remove Ring Station MAC frame            request.  When this frame is received            the interface will enter the close state            and dot5RingState will signify this            condition."    ::= { dot5StatsEntry 17 }dot5StatsSingles OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "The number of times the interface has            sensed that it is the only station on the            ring.  This will happen if the interface            is the first one up on a ring, or if            there is a hardware problem."    ::= { dot5StatsEntry 18 }dot5StatsFreqErrors OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "The number of times the interface has            detected that the frequency of the            incoming signal differs from the expected            frequency by more than that specified by            the IEEE 802.5 standard."    ::= { dot5StatsEntry 19 }McCloghrie & Decker                                            [Page 15]RFC 1743               IEEE 802.5 MIB using SMIv2          December 1994-- The Timer Table-- This group contains the values of timers for 802.5-- interfaces.  This table is obsolete, but its definition-- is retained here for backwards compatibility.dot5TimerTable  OBJECT-TYPE    SYNTAX      SEQUENCE OF Dot5TimerEntry    MAX-ACCESS  not-accessible    STATUS      obsolete    DESCRIPTION            "This table contains Token Ring interface            timer values, one entry per 802.5            interface."    ::= { dot5 5 }dot5TimerEntry  OBJECT-TYPE    SYNTAX      Dot5TimerEntry    MAX-ACCESS  not-accessible    STATUS      obsolete    DESCRIPTION            "A list of Token Ring timer values for an            802.5 interface."    INDEX       { dot5TimerIfIndex }    ::= { dot5TimerTable 1 }Dot5TimerEntry ::= SEQUENCE {    dot5TimerIfIndex          Integer32,    dot5TimerReturnRepeat     Integer32,    dot5TimerHolding          Integer32,    dot5TimerQueuePDU         Integer32,    dot5TimerValidTransmit    Integer32,    dot5TimerNoToken          Integer32,    dot5TimerActiveMon        Integer32,    dot5TimerStandbyMon       Integer32,    dot5TimerErrorReport      Integer32,    dot5TimerBeaconTransmit   Integer32,    dot5TimerBeaconReceive    Integer32}dot5TimerIfIndex  OBJECT-TYPE    SYNTAX      Integer32    MAX-ACCESS  read-only    STATUS      obsolete    DESCRIPTION            "The value of this object identifies the             802.5 interface for which this entry             contains timer values.  The value ofMcCloghrie & Decker                                            [Page 16]RFC 1743               IEEE 802.5 MIB using SMIv2          December 1994             this object for a particular interface             has the same value as MIB-II's ifIndex             object for the same interface."    ::= { dot5TimerEntry 1 }dot5TimerReturnRepeat  OBJECT-TYPE    SYNTAX      Integer32    MAX-ACCESS  read-only    STATUS      obsolete    DESCRIPTION            "The time-out value used to ensure the            interface will return to Repeat State, in            units of 100 micro-seconds.  The value            should be greater than the maximum ring            latency."    ::= { dot5TimerEntry 2 }dot5TimerHolding  OBJECT-TYPE    SYNTAX      Integer32    MAX-ACCESS  read-only    STATUS      obsolete    DESCRIPTION            "Maximum period of time a station is            permitted to transmit frames after capturing            a token, in units of 100 micro-seconds."    ::= { dot5TimerEntry 3 }dot5TimerQueuePDU  OBJECT-TYPE    SYNTAX      Integer32    MAX-ACCESS  read-only    STATUS      obsolete    DESCRIPTION            "The time-out value for enqueuing of an SMP            PDU after reception of an AMP or SMP

⌨️ 快捷键说明

复制代码Ctrl + C
搜索代码Ctrl + F
全屏模式F11
增大字号Ctrl + =
减小字号Ctrl + -
显示快捷键?