rfc1743.txt
来自「著名的RFC文档,其中有一些文档是已经翻译成中文的的.」· 文本 代码 · 共 1,404 行 · 第 1/3 页
TXT
1,404 行
false(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "If this object has a value of true(1) then this interface will participate in the active monitor selection process. If the value is false(2) then it will not. Setting this object does not take effect until the next Active Monitor election, and might not take effect until the next time the interface is opened." ::= { dot5Entry 8 }dot5Functional OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The bit mask of all Token Ring functional addresses for which this interface will accept frames." ::= { dot5Entry 9 }dot5LastBeaconSent OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of MIB-II's sysUpTime object at which the local system last transmitted a Beacon frame on this interface." ::= { dot5Entry 10 }McCloghrie & Decker [Page 9]RFC 1743 IEEE 802.5 MIB using SMIv2 December 1994-- The 802.5 Statistics Table-- This table contains statistics and error counter which are-- specific to 802.5 interfaces. It is mandatory that systems-- having 802.5 interfaces implement this table.dot5StatsTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot5StatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing Token Ring statistics, one entry per 802.5 interface. All the statistics are defined using the syntax Counter32 as 32-bit wrap around counters. Thus, if an interface's hardware maintains these statistics in 16-bit counters, then the agent must read the hardware's counters frequently enough to prevent loss of significance, in order to maintain 32-bit counters in software." ::= { dot5 2 }dot5StatsEntry OBJECT-TYPE SYNTAX Dot5StatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains the 802.5 statistics for a particular interface." INDEX { dot5StatsIfIndex } ::= { dot5StatsTable 1 }Dot5StatsEntry ::= SEQUENCE { dot5StatsIfIndex Integer32, dot5StatsLineErrors Counter32, dot5StatsBurstErrors Counter32, dot5StatsACErrors Counter32, dot5StatsAbortTransErrors Counter32, dot5StatsInternalErrors Counter32, dot5StatsLostFrameErrors Counter32, dot5StatsReceiveCongestions Counter32, dot5StatsFrameCopiedErrors Counter32, dot5StatsTokenErrors Counter32, dot5StatsSoftErrors Counter32, dot5StatsHardErrors Counter32, dot5StatsSignalLoss Counter32,McCloghrie & Decker [Page 10]RFC 1743 IEEE 802.5 MIB using SMIv2 December 1994 dot5StatsTransmitBeacons Counter32, dot5StatsRecoverys Counter32, dot5StatsLobeWires Counter32, dot5StatsRemoves Counter32, dot5StatsSingles Counter32, dot5StatsFreqErrors Counter32}dot5StatsIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the 802.5 interface for which this entry contains management information. The value of this object for a particular interface has the same value as MIB-II's ifIndex object for the same interface." ::= { dot5StatsEntry 1 }dot5StatsLineErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when a frame or token is copied or repeated by a station, the E bit is zero in the frame or token and one of the following conditions exists: 1) there is a non-data bit (J or K bit) between the SD and the ED of the frame or token, or 2) there is an FCS error in the frame." ::= { dot5StatsEntry 2 }dot5StatsBurstErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when a station detects the absence of transitions for five half-bit timers (burst-five error)." ::= { dot5StatsEntry 3 }McCloghrie & Decker [Page 11]RFC 1743 IEEE 802.5 MIB using SMIv2 December 1994dot5StatsACErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when a station receives an AMP or SMP frame in which A is equal to C is equal to 0, and then receives another SMP frame with A is equal to C is equal to 0 without first receiving an AMP frame. It denotes a station that cannot set the AC bits properly." ::= { dot5StatsEntry 4 }dot5StatsAbortTransErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when a station transmits an abort delimiter while transmitting." ::= { dot5StatsEntry 5 }dot5StatsInternalErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when a station recognizes an internal error." ::= { dot5StatsEntry 6 }dot5StatsLostFrameErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when a station is transmitting and its TRR timer expires. This condition denotes a condition where a transmitting station in strip mode does not receive the trailer of the frame before the TRR timer goes off." ::= { dot5StatsEntry 7 }McCloghrie & Decker [Page 12]RFC 1743 IEEE 802.5 MIB using SMIv2 December 1994dot5StatsReceiveCongestions OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when a station recognizes a frame addressed to its specific address, but has no available buffer space indicating that the station is congested." ::= { dot5StatsEntry 8 }dot5StatsFrameCopiedErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when a station recognizes a frame addressed to its specific address and detects that the FS field A bits are set to 1 indicating a possible line hit or duplicate address." ::= { dot5StatsEntry 9 }dot5StatsTokenErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when a station acting as the active monitor recognizes an error condition that needs a token transmitted." ::= { dot5StatsEntry 10 }dot5StatsSoftErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Soft Errors the interface has detected. It directly corresponds to the number of Report Error MAC frames that this interface has transmitted. Soft Errors are those which are recoverable by the MAC layer protocols." ::= { dot5StatsEntry 11 }McCloghrie & Decker [Page 13]RFC 1743 IEEE 802.5 MIB using SMIv2 December 1994dot5StatsHardErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times this interface has detected an immediately recoverable fatal error. It denotes the number of times this interface is either transmitting or receiving beacon MAC frames." ::= { dot5StatsEntry 12 }dot5StatsSignalLoss OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times this interface has detected the loss of signal condition from the ring." ::= { dot5StatsEntry 13 }dot5StatsTransmitBeacons OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times this interface has transmitted a beacon frame." ::= { dot5StatsEntry 14 }dot5StatsRecoverys OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Claim Token MAC frames received or transmitted after the interface has received a Ring Purge MAC frame. This counter signifies the number of times the ring has been purged and is being recovered back into a normal operating state." ::= { dot5StatsEntry 15 }dot5StatsLobeWires OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-onlyMcCloghrie & Decker [Page 14]RFC 1743 IEEE 802.5 MIB using SMIv2 December 1994 STATUS current DESCRIPTION "The number of times the interface has detected an open or short circuit in the lobe data path. The adapter will be closed and dot5RingState will signify this condition." ::= { dot5StatsEntry 16 }dot5StatsRemoves OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the interface has received a Remove Ring Station MAC frame request. When this frame is received the interface will enter the close state and dot5RingState will signify this condition." ::= { dot5StatsEntry 17 }dot5StatsSingles OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the interface has sensed that it is the only station on the ring. This will happen if the interface is the first one up on a ring, or if there is a hardware problem." ::= { dot5StatsEntry 18 }dot5StatsFreqErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the interface has detected that the frequency of the incoming signal differs from the expected frequency by more than that specified by the IEEE 802.5 standard." ::= { dot5StatsEntry 19 }McCloghrie & Decker [Page 15]RFC 1743 IEEE 802.5 MIB using SMIv2 December 1994-- The Timer Table-- This group contains the values of timers for 802.5-- interfaces. This table is obsolete, but its definition-- is retained here for backwards compatibility.dot5TimerTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot5TimerEntry MAX-ACCESS not-accessible STATUS obsolete DESCRIPTION "This table contains Token Ring interface timer values, one entry per 802.5 interface." ::= { dot5 5 }dot5TimerEntry OBJECT-TYPE SYNTAX Dot5TimerEntry MAX-ACCESS not-accessible STATUS obsolete DESCRIPTION "A list of Token Ring timer values for an 802.5 interface." INDEX { dot5TimerIfIndex } ::= { dot5TimerTable 1 }Dot5TimerEntry ::= SEQUENCE { dot5TimerIfIndex Integer32, dot5TimerReturnRepeat Integer32, dot5TimerHolding Integer32, dot5TimerQueuePDU Integer32, dot5TimerValidTransmit Integer32, dot5TimerNoToken Integer32, dot5TimerActiveMon Integer32, dot5TimerStandbyMon Integer32, dot5TimerErrorReport Integer32, dot5TimerBeaconTransmit Integer32, dot5TimerBeaconReceive Integer32}dot5TimerIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object identifies the 802.5 interface for which this entry contains timer values. The value ofMcCloghrie & Decker [Page 16]RFC 1743 IEEE 802.5 MIB using SMIv2 December 1994 this object for a particular interface has the same value as MIB-II's ifIndex object for the same interface." ::= { dot5TimerEntry 1 }dot5TimerReturnRepeat OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The time-out value used to ensure the interface will return to Repeat State, in units of 100 micro-seconds. The value should be greater than the maximum ring latency." ::= { dot5TimerEntry 2 }dot5TimerHolding OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Maximum period of time a station is permitted to transmit frames after capturing a token, in units of 100 micro-seconds." ::= { dot5TimerEntry 3 }dot5TimerQueuePDU OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The time-out value for enqueuing of an SMP PDU after reception of an AMP or SMP
⌨️ 快捷键说明
复制代码Ctrl + C
搜索代码Ctrl + F
全屏模式F11
增大字号Ctrl + =
减小字号Ctrl + -
显示快捷键?