rfc2006.txt

来自「著名的RFC文档,其中有一些文档是已经翻译成中文的的.」· 文本 代码 · 共 2,027 行 · 第 1/5 页

TXT
2,027
字号
        STATUS      current        DESCRIPTION                "The sequence number of the most recently received                advertisement. The sequence number ranges from 0 to                0xffff. After the sequence number attains the value                0xffff, it will roll over to 256."        ::= { mnRecentAdvReceived 2 }    mnAdvFlags OBJECT-TYPE        SYNTAX      BITS {                         vjCompression(0),                         gre(1),                         minEnc(2),                         foreignAgent(3),                         homeAgent(4),                         busy(5),                         regRequired(6)                    }        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                "The flags are contained in the 7th byte in the                extension of the most recently received mobility agent                advertisement:                    vjCompression                        -- Agent supports Van Jacobson compressionCong, Hamlen & Perkins      Standards Track                    [Page 15]RFC 2006          Mobile IP MIB Definition using SMIv2      October 1996                    gre                        -- Agent offers Generice Routing Encapsulation                    minEnc,                        -- Agent offers Minimal Encapsulation                    foreignAgent,                        -- Agent is a Foreign Agent                    homeAgent,                        -- Agent is a Home Agent                    busy,                        -- Foreign Agent is busy                    regRequired,                        -- FA registration is required."        ::= { mnRecentAdvReceived 3 }    mnAdvMaxRegLifetime OBJECT-TYPE        SYNTAX      INTEGER (0..65535)        UNITS       "seconds"        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                "The longest lifetime in seconds that the agent is                willing to accept in any registration request."        ::= { mnRecentAdvReceived 4 }    mnAdvMaxAdvLifetime OBJECT-TYPE        SYNTAX      INTEGER (0..65535)        UNITS       "seconds"        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                "The maximum length of time that the Advertisement is                considered valid in the absence of further                Advertisements."        REFERENCE                "AdvertisementLifeTime in RFC1256."        ::= { mnRecentAdvReceived 5 }    mnAdvTimeReceived OBJECT-TYPE        SYNTAX      TimeStamp        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                "The time at which the most recently received                advertisement was received."        ::= { mnRecentAdvReceived 6 }   -- Mobile Node Discovery Group CounterCong, Hamlen & Perkins      Standards Track                    [Page 16]RFC 2006          Mobile IP MIB Definition using SMIv2      October 1996    mnSolicitationsSent OBJECT-TYPE        SYNTAX      Counter32        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                "Total number of Solicitation sent by the mobile                node."        ::= { mnDiscovery 3 }    mnAdvertisementsReceived OBJECT-TYPE        SYNTAX      Counter32        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                "Total number of advertisements received by the mobile                node."        ::= { mnDiscovery 4 }    mnAdvsDroppedInvalidExtension OBJECT-TYPE        SYNTAX      Counter32        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                "Total number of advertisements dropped by the mobile                node due to both poorly formed extensions and                unrecognized extensions with extension number in the                range 0-127."        ::= { mnDiscovery 5 }    mnAdvsIgnoredUnknownExtension OBJECT-TYPE        SYNTAX      Counter32        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                "Total number of unrecognized extensions in the range                128-255 that were ignored by the mobile node."        ::= { mnDiscovery 6 }    mnMoveFromHAToFA OBJECT-TYPE        SYNTAX      Counter32        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                "Number of times that the mobile node has decided to                move from its home network to a foreign network."        ::= { mnDiscovery 7 }    mnMoveFromFAToFA OBJECT-TYPECong, Hamlen & Perkins      Standards Track                    [Page 17]RFC 2006          Mobile IP MIB Definition using SMIv2      October 1996        SYNTAX      Counter32        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                "Number of times that the mobile node has decided to                move from one foreign network to another foreign                network."        ::= { mnDiscovery 8 }    mnMoveFromFAToHA OBJECT-TYPE        SYNTAX      Counter32        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                "Number of times that the mobile node has decided to                move from a foreign network to its home network."        ::= { mnDiscovery 9 }    mnGratuitousARPsSend OBJECT-TYPE        SYNTAX      Counter32        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                "Total number of Gratuitous ARPs sent by mobile node                in order to clear out any stale ARP entries in the ARP                caches of nodes on the home network."        ::= { mnDiscovery 10 }    mnAgentRebootsDectected OBJECT-TYPE        SYNTAX      Counter32        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                "Total number of agent reboots detected by the mobile                node through sequence number of the advertisement."        ::= { mnDiscovery 11 }    -- Mobile Node Registration Group    -- Registration table of mobile node    mnRegistrationTable OBJECT-TYPE        SYNTAX      SEQUENCE OF MnRegistrationEntry        MAX-ACCESS  not-accessible        STATUS      current        DESCRIPTION                "A table containing information about the mobile                node's attempted registration(s).  The mobile nodeCong, Hamlen & Perkins      Standards Track                    [Page 18]RFC 2006          Mobile IP MIB Definition using SMIv2      October 1996                updates this table based upon Registration Requests                sent and Registration Replies received in response to                these requests.  Certain variables within this table                are also updated if when Registration Requests are                retransmitted."        ::= { mnRegistration 1 }    mnRegistrationEntry OBJECT-TYPE        SYNTAX      MnRegistrationEntry        MAX-ACCESS  not-accessible        STATUS      current        DESCRIPTION                "Information about one registration attempt."        INDEX { mnRegAgentAddress, mnRegCOA}        ::= { mnRegistrationTable 1 }    MnRegistrationEntry ::= SEQUENCE {        mnRegAgentAddress IpAddress,        mnRegCOA IpAddress,        mnRegFlags RegistrationFlags,        mnRegIDLow Integer32,        mnRegIDHigh Integer32,        mnRegTimeRequested Integer32,        mnRegTimeRemaining  Gauge32,        mnRegTimeSent    TimeStamp,        mnRegIsAccepted  TruthValue,        mnCOAIsLocal     TruthValue        }    mnRegAgentAddress OBJECT-TYPE        SYNTAX      IpAddress        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                 "IP address of the agent as used in the destination                 IP address of the Registration Request.  The agent                 may be a home agent or a foreign agent."        ::= { mnRegistrationEntry 1 }    mnRegCOA OBJECT-TYPE        SYNTAX      IpAddress        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                "Care-of address for the registration."        ::= { mnRegistrationEntry 2 }    mnRegFlags OBJECT-TYPECong, Hamlen & Perkins      Standards Track                    [Page 19]RFC 2006          Mobile IP MIB Definition using SMIv2      October 1996        SYNTAX      RegistrationFlags        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                "Registration flags sent by the mobile node. It is the                second byte in the Mobile IP Registratation Request                message."        ::= { mnRegistrationEntry 3 }    mnRegIDLow OBJECT-TYPE        SYNTAX      Integer32        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                "Low-order 32 bits of the Identification used in that                registration by the mobile node."        ::= { mnRegistrationEntry 4 }    mnRegIDHigh OBJECT-TYPE        SYNTAX      Integer32        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                "High-order 32 bits of the Identification used in that                registration by the mobile node."        ::= { mnRegistrationEntry 5 }    mnRegTimeRequested OBJECT-TYPE        SYNTAX      Integer32        UNITS       "seconds"        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                "If the registration is pending, then this is the                lifetime requested by the mobile node (in seconds).                If the registration has been accepted, then this is                the lifetime actually granted by the home agent in the                reply."        ::= { mnRegistrationEntry 6 }    mnRegTimeRemaining OBJECT-TYPE        SYNTAX      Gauge32        UNITS       "seconds"        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                "The number of seconds remaining until this                registration expires.  It has the same initial valueCong, Hamlen & Perkins      Standards Track                    [Page 20]RFC 2006          Mobile IP MIB Definition using SMIv2      October 1996                as mnRegTimeRequested and is only valid if                mnRegIsAccepted is TRUE."        ::= { mnRegistrationEntry 7 }    mnRegTimeSent OBJECT-TYPE        SYNTAX      TimeStamp        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                "The time when the last (re-)transmission occured."        ::= { mnRegistrationEntry 8 }    mnRegIsAccepted OBJECT-TYPE        SYNTAX      TruthValue        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                "true(1) if the mobile node has received a                Registration Reply indicating that service has been                accepted; false(2) otherwise.  false(2) implies that                the registration is still pending."        ::= { mnRegistrationEntry 9 }    mnCOAIsLocal OBJECT-TYPE        SYNTAX      TruthValue        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                "Whether the COA is local to (dynamically acquired by)                the mobile node or not.  If it is false(2), the COA is                an address of the foreign agent."        ::= { mnRegistrationEntry 10 }    -- Mobile Node Registration Group Counters    mnRegRequestsSent OBJECT-TYPE        SYNTAX      Counter32        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                "Total number of registration requests sent by the                mobile node. This does not include deregistrations                (those with Lifetime equal to zero)."        ::= { mnRegistration 2 }    mnDeRegRequestsSent OBJECT-TYPE        SYNTAX      Counter32        MAX-ACCESS  read-onlyCong, Hamlen & Perkins      Standards Track                    [Page 21]RFC 2006          Mobile IP MIB Definition using SMIv2      October 1996        STATUS      current        DESCRIPTION                "Total number of deregistration requests sent by the                mobile node (those with Lifetime equal to zero)."        ::= { mnRegistration 3 }    mnRegRepliesRecieved OBJECT-TYPE        SYNTAX      Counter32        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                "Total number of registration replies received by the                mobile node in which the Lifetime is greater than                zero."        ::= { mnRegistration 4 }    mnDeRegRepliesRecieved OBJECT-TYPE        SYNTAX      Counter32        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                "Total number of (de)registration replies received by                the mobile node in which the Lifetime is equal to                zero."        ::= { mnRegistration 5 }    mnRepliesInvalidHomeAddress OBJECT-TYPE        SYNTAX      Counter32        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION                "Total number of replies with invalid home address for                the mobile node."        ::= { mnRegistration 6 }    mnRepliesUnknownHA OBJECT-TYPE

⌨️ 快捷键说明

复制代码Ctrl + C
搜索代码Ctrl + F
全屏模式F11
增大字号Ctrl + =
减小字号Ctrl + -
显示快捷键?