⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc1628.txt

📁 著名的RFC文档,其中有一些文档是已经翻译成中文的的.
💻 TXT
📖 第 1 页 / 共 5 页
字号:
       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "Additional information about upsTestResultsSummary.               If no additional information available, a zero length               string is returned."       ::= { upsTest 4 }   upsTestStartTime OBJECT-TYPE       SYNTAX     TimeStamp       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "The value of sysUpTime at the time the test in               progress was initiated, or, if no test is in progress,               the time the previous test was initiated.  If the               value of upsTestResultsSummary is noTestsInitiated(6),               upsTestStartTime has the value 0."       ::= { upsTest 5 }   upsTestElapsedTime OBJECT-TYPE       SYNTAX     TimeInterval       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "The amount of time, in TimeTicks, since the test in               progress was initiated, or, if no test is in progress,               the previous test took to complete.  If the value of               upsTestResultsSummary is noTestsInitiated(6),               upsTestElapsedTime has the value 0."       ::= { upsTest 6 }   --   -- Well known tests.   --   upsWellKnownTests     OBJECT IDENTIFIER ::= { upsTest 7 }   upsTestNoTestsInitiated OBJECT-IDENTITY       STATUS     current       DESCRIPTION               "No tests have been initiated and no test is in               progress."       ::= { upsWellKnownTests  1 }   upsTestAbortTestInProgress OBJECT-IDENTITY       STATUS     currentCase                                                           [Page 22]RFC 1628                        UPS MIB                         May 1994       DESCRIPTION               "The test in progress is to be aborted / the test in               progress was aborted."       ::= { upsWellKnownTests  2 }   upsTestGeneralSystemsTest OBJECT-IDENTITY       STATUS     current       DESCRIPTION               "The manufacturer's standard test of UPS device               systems."       ::= { upsWellKnownTests  3 }   upsTestQuickBatteryTest OBJECT-IDENTITY       STATUS     current       DESCRIPTION               "A test that is sufficient to determine if the battery               needs replacement."       ::= { upsWellKnownTests  4 }   upsTestDeepBatteryCalibration OBJECT-IDENTITY       STATUS     current       DESCRIPTION               "The system is placed on battery to a discharge level,               set by the manufacturer, sufficient to determine               battery replacement and battery run-time with a high               degree of confidence.  WARNING:  this test will leave               the battery in a low charge state and will require               time for recharging to a level sufficient to provide               normal battery duration for the protected load."       ::= { upsWellKnownTests  5 }   --   -- The Control group.   --   upsControl            OBJECT IDENTIFIER ::= { upsObjects 8 }   upsShutdownType OBJECT-TYPE       SYNTAX     INTEGER {           output(1),           system(2)       }       MAX-ACCESS read-write       STATUS     current       DESCRIPTION               "This object determines the nature of the action to be               taken at the time when the countdown of theCase                                                           [Page 23]RFC 1628                        UPS MIB                         May 1994               upsShutdownAfterDelay and upsRebootWithDuration               objects reaches zero.               Setting this object to output(1) indicates that               shutdown requests should cause only the output of the               UPS to turn off.  Setting this object to system(2)               indicates that shutdown requests will cause the entire               UPS system to turn off."       ::= { upsControl 1 }   upsShutdownAfterDelay OBJECT-TYPE       SYNTAX     INTEGER (-1..2147483648)       UNITS      "seconds"       MAX-ACCESS read-write       STATUS     current       DESCRIPTION               "Setting this object will shutdown (i.e., turn off)               either the UPS output or the UPS system (as determined               by the value of upsShutdownType at the time of               shutdown) after the indicated number of seconds, or               less if the UPS batteries become depleted. Setting               this object to 0 will cause the shutdown to occur               immediately.  Setting this object to -1 will abort the               countdown.  If the system is already in the desired               state at the time the countdown reaches 0, then               nothing will happen.  That is, there is no additional               action at that time if upsShutdownType = system and               the system is already off.  Similarly, there is no               additional action at that time if upsShutdownType =               output and the output is already off.  When read,               upsShutdownAfterDelay will return the number of               seconds remaining until shutdown, or -1 if no shutdown               countdown is in effect.  On some systems, if the agent               is restarted while a shutdown countdown is in effect,               the countdown may be aborted.  Sets to this object               override any upsShutdownAfterDelay already in effect."       ::= { upsControl 2 }   upsStartupAfterDelay OBJECT-TYPE       SYNTAX     INTEGER (-1..2147483648)       UNITS      "seconds"       MAX-ACCESS read-write       STATUS     current       DESCRIPTION               "Setting this object will start the output after the               indicated number of seconds, including starting the               UPS, if necessary.  Setting this object to 0 will               cause the startup to occur immediately.  Setting thisCase                                                           [Page 24]RFC 1628                        UPS MIB                         May 1994               object to -1 will abort the countdown.  If the output               is already on at the time the countdown reaches 0,               then nothing will happen.  Sets to this object               override the effect of any upsStartupAfterDelay               countdown or upsRebootWithDuration countdown in               progress.  When read, upsStartupAfterDelay will return               the number of seconds until startup, or -1 if no               startup countdown is in effect.  If the countdown               expires during a utility failure, the startup shall               not occur until the utility power is restored.  On               some systems, if the agent is restarted while a               startup countdown is in effect, the countdown is               aborted."       ::= { upsControl 3 }   upsRebootWithDuration OBJECT-TYPE       SYNTAX     INTEGER (-1..300)       UNITS      "seconds"       MAX-ACCESS read-write       STATUS     current       DESCRIPTION               "Setting this object will immediately shutdown (i.e.,               turn off) either the UPS output or the UPS system (as               determined by the value of upsShutdownType at the time               of shutdown) for a period equal to the indicated               number of seconds, after which time the output will be               started, including starting the UPS, if necessary.  If               the number of seconds required to perform the request               is greater than the requested duration, then the               requested shutdown and startup cycle shall be               performed in the minimum time possible, but in no case               shall this require more than the requested duration               plus 60 seconds.  When read, upsRebootWithDuration               shall return the number of seconds remaining in the               countdown, or -1 if no countdown is in progress.  If               the startup should occur during a utility failure, the               startup shall not occur until the utility power is               restored."       ::= { upsControl 4 }   upsAutoRestart OBJECT-TYPE       SYNTAX     INTEGER {           on(1),           off(2)       }       MAX-ACCESS read-write       STATUS     current       DESCRIPTIONCase                                                           [Page 25]RFC 1628                        UPS MIB                         May 1994               "Setting this object to 'on' will cause the UPS system               to restart after a shutdown if the shutdown occurred               during a power loss as a result of either a               upsShutdownAfterDelay or an internal battery depleted               condition.  Setting this object to 'off' will prevent               the UPS system from restarting after a shutdown until               an operator manually or remotely explicitly restarts               it.  If the UPS is in a startup or reboot countdown,               then the UPS will not restart until that delay has               been satisfied."       ::= { upsControl 5 }   --   -- The Configuration group.   --   upsConfig             OBJECT IDENTIFIER ::= { upsObjects 9 }   upsConfigInputVoltage OBJECT-TYPE       SYNTAX     NonNegativeInteger       UNITS      "RMS Volts"       MAX-ACCESS read-write       STATUS     current       DESCRIPTION               "The magnitude of the nominal input voltage.  On those               systems which support read-write access to this               object, if there is an attempt to set this variable to               a value that is not supported, the request must be               rejected and the agent shall respond with an               appropriate error message, i.e., badValue for SNMPv1,               or inconsistentValue for SNMPv2."       ::= { upsConfig 1 }   upsConfigInputFreq OBJECT-TYPE       SYNTAX     NonNegativeInteger       UNITS      "0.1 Hertz"       MAX-ACCESS read-write       STATUS     current       DESCRIPTION               "The nominal input frequency.  On those systems which               support read-write access to this object, if there is               an attempt to set this variable to a value that is not               supported, the request must be rejected and the agent               shall respond with an appropriate error message, i.e.,               badValue for SNMPv1, or inconsistentValue for SNMPv2."       ::= { upsConfig 2 }Case                                                           [Page 26]RFC 1628                        UPS MIB                         May 1994   upsConfigOutputVoltage OBJECT-TYPE       SYNTAX     NonNegativeInteger       UNITS      "RMS Volts"       MAX-ACCESS read-write       STATUS     current       DESCRIPTION               "The magnitude of the nominal output voltage.  On               those systems which support read-write access to this               object, if there is an attempt to set this variable to               a value that is not supported, the request must be               rejected and the agent shall respond with an               appropriate error message, i.e., badValue for SNMPv1,               or inconsistentValue for SNMPv2."       ::= { upsConfig 3 }   upsConfigOutputFreq OBJECT-TYPE       SYNTAX     NonNegativeInteger       UNITS      "0.1 Hertz"       MAX-ACCESS read-write       STATUS     current       DESCRIPTION               "The nominal output frequency.  On those systems which               support read-write access to this object, if there is               an attempt to set this variable to a value that is not               supported, the request must be rejected and the agent               shall respond with an appropriate error message, i.e.,               badValue for SNMPv1, or inconsistentValue for SNMPv2."       ::= { upsConfig 4 }   upsConfigOutputVA OBJECT-TYPE       SYNTAX     NonNegativeInteger       UNITS      "Volt-Amps"       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "The magnitude of the nominal Volt-Amp rating."       ::= { upsConfig 5 }   upsConfigOutputPower OBJECT-TYPE       SYNTAX     NonNegativeInteger       UNITS      "Watts"       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "The magnitude of the nominal true power rating."       ::= { upsConfig 6 }   upsConfigLowBattTime OBJECT-TYPECase                                                           [Page 27]RFC 1628                        UPS MIB                         May 1994       SYNTAX     NonNegativeInteger       UNITS      "minutes"       MAX-ACCESS read-write       STATUS     current       DESCRIPTION               "The value of upsEstimatedMinutesRemaining at which a               lowBattery condition is declared.  For agents which               support only discrete (discontinuous) values, then the               agent shall round up to the next supported value.  If               the requested value is larger than the largest               supported value, then the largest supported value               shall be selected."       ::= { upsConfig 7 }   upsConfigAudibleStatus OBJECT-TYPE       SYNTAX     INTEGER {           disabled(1),           enabled(2),           muted(3)       }       MAX-ACCESS read-write       STATUS     current       DESCRIPTION               "The requested state of the audible alarm.  When in               the disabled state, the audible alarm should never               sound.  The enabled state is self-describing.  Setting               this object to muted(3) when the audible alarm is               sounding shall temporarily silence the alarm.  It will               remain muted until it would normally stop sounding and               the value returned for read operations during this               period shall equal muted(3).  At the end of this               period, the value shall revert to enabled(2).  Writes               of the value muted(3) when the audible alarm is not               sounding shall be accepted but otherwise shall have no               effect."       ::= { upsConfig 8 }   upsConfigLowVoltageTransferPoint OBJECT-TYPE       SYNTAX     NonNegativeInteger       UNITS      "RMS Volts"       MAX-ACCESS read-write       STATUS     current       DESCRIPTION               "The minimum input line voltage allowed before the UPS               system transfers to battery backup."       ::= { upsConfig 9 }   upsConfigHighVoltageTransferPoint OBJECT-TYPECase                                                           [Page 28]RFC 1628                        UPS MIB                         May 1994       SYNTAX     NonNegativeInteger       UNITS      "RMS Volts"

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -