particular alarm." INDEX { upsAlarmId } ::= { upsAlarmTable 1 } UpsAlarmEntry ::= SEQUENCE { upsAlarmId PositiveInteger, upsAlarmDescr AutonomousType, upsAlarmTime TimeStamp } upsAlarmId OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique identifier for an alarm condition. This value must remain constant." ::= { upsAlarmEntry 1 } upsAlarmDescr OBJECT-TYPE SYNTAX AutonomousType MAX-ACCESS read-only STATUS current DESCRIPTION "A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition." ::= { upsAlarmEntry 2 } upsAlarmTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of upsAlarmTime shall equal 0." ::= { upsAlarmEntry 3 } -- -- Well known alarm conditions. -- upsWellKnownAlarms OBJECT IDENTIFIER ::= { upsAlarm 3 }Case [Page 15]RFC 1628 UPS MIB May 1994 upsAlarmBatteryBad OBJECT-IDENTITY STATUS current DESCRIPTION "One or more batteries have been determined to require replacement." ::= { upsWellKnownAlarms 1 } upsAlarmOnBattery OBJECT-IDENTITY STATUS current DESCRIPTION "The UPS is drawing power from the batteries." ::= { upsWellKnownAlarms 2 } upsAlarmLowBattery OBJECT-IDENTITY STATUS current DESCRIPTION "The remaining battery run-time is less than or equal to upsConfigLowBattTime." ::= { upsWellKnownAlarms 3 } upsAlarmDepletedBattery OBJECT-IDENTITY STATUS current DESCRIPTION "The UPS will be unable to sustain the present load when and if the utility power is lost." ::= { upsWellKnownAlarms 4 } upsAlarmTempBad OBJECT-IDENTITY STATUS current DESCRIPTION "A temperature is out of tolerance." ::= { upsWellKnownAlarms 5 } upsAlarmInputBad OBJECT-IDENTITY STATUS current DESCRIPTION "An input condition is out of tolerance." ::= { upsWellKnownAlarms 6 } upsAlarmOutputBad OBJECT-IDENTITY STATUS current DESCRIPTION "An output condition (other than OutputOverload) is out of tolerance." ::= { upsWellKnownAlarms 7 } upsAlarmOutputOverload OBJECT-IDENTITYCase [Page 16]RFC 1628 UPS MIB May 1994 STATUS current DESCRIPTION "The output load exceeds the UPS output capacity." ::= { upsWellKnownAlarms 8 } upsAlarmOnBypass OBJECT-IDENTITY STATUS current DESCRIPTION "The Bypass is presently engaged on the UPS." ::= { upsWellKnownAlarms 9 } upsAlarmBypassBad OBJECT-IDENTITY STATUS current DESCRIPTION "The Bypass is out of tolerance." ::= { upsWellKnownAlarms 10 } upsAlarmOutputOffAsRequested OBJECT-IDENTITY STATUS current DESCRIPTION "The UPS has shutdown as requested, i.e., the output is off." ::= { upsWellKnownAlarms 11 } upsAlarmUpsOffAsRequested OBJECT-IDENTITY STATUS current DESCRIPTION "The entire UPS has shutdown as commanded." ::= { upsWellKnownAlarms 12 } upsAlarmChargerFailed OBJECT-IDENTITY STATUS current DESCRIPTION "An uncorrected problem has been detected within the UPS charger subsystem." ::= { upsWellKnownAlarms 13 } upsAlarmUpsOutputOff OBJECT-IDENTITY STATUS current DESCRIPTION "The output of the UPS is in the off state." ::= { upsWellKnownAlarms 14 } upsAlarmUpsSystemOff OBJECT-IDENTITY STATUS current DESCRIPTION "The UPS system is in the off state." ::= { upsWellKnownAlarms 15 }Case [Page 17]RFC 1628 UPS MIB May 1994 upsAlarmFanFailure OBJECT-IDENTITY STATUS current DESCRIPTION "The failure of one or more fans in the UPS has been detected." ::= { upsWellKnownAlarms 16 } upsAlarmFuseFailure OBJECT-IDENTITY STATUS current DESCRIPTION "The failure of one or more fuses has been detected." ::= { upsWellKnownAlarms 17 } upsAlarmGeneralFault OBJECT-IDENTITY STATUS current DESCRIPTION "A general fault in the UPS has been detected." ::= { upsWellKnownAlarms 18 } upsAlarmDiagnosticTestFailed OBJECT-IDENTITY STATUS current DESCRIPTION "The result of the last diagnostic test indicates a failure." ::= { upsWellKnownAlarms 19 } upsAlarmCommunicationsLost OBJECT-IDENTITY STATUS current DESCRIPTION "A problem has been encountered in the communications between the agent and the UPS." ::= { upsWellKnownAlarms 20 } upsAlarmAwaitingPower OBJECT-IDENTITY STATUS current DESCRIPTION "The UPS output is off and the UPS is awaiting the return of input power." ::= { upsWellKnownAlarms 21 } upsAlarmShutdownPending OBJECT-IDENTITY STATUS current DESCRIPTION "A upsShutdownAfterDelay countdown is underway." ::= { upsWellKnownAlarms 22 } upsAlarmShutdownImminent OBJECT-IDENTITY STATUS currentCase [Page 18]RFC 1628 UPS MIB May 1994 DESCRIPTION "The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown." ::= { upsWellKnownAlarms 23 } upsAlarmTestInProgress OBJECT-IDENTITY STATUS current DESCRIPTION "A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY." ::= { upsWellKnownAlarms 24 } -- -- The Test Group -- upsTest OBJECT IDENTIFIER ::= { upsObjects 7 } upsTestId OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-write STATUS current DESCRIPTION "The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of upsTestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in upsTestResultsSummary. Tests in progress may be aborted by setting the upsTestId variable toCase [Page 19]RFC 1628 UPS MIB May 1994 upsTestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value upsTestNoTestsInitiated is returned." ::= { upsTest 1 } -- see [6] for more information on the semantics of objects with -- syntax of TestAndIncr upsTestSpinLock OBJECT-TYPE SYNTAX TestAndIncr MAX-ACCESS read-write STATUS current DESCRIPTION "A spin lock on the test subsystem. The spinlock is used as follows. Before starting a test, a manager-station should make sure that a test is not in progress as follows: try_again: get (upsTestSpinLock) while (upsTestResultsSummary == inProgress) { /* loop while a test is running for another manager */ short delay get (upsTestSpinLock) } lock_value = upsTestSpinLock /* no test in progress, start the test */ set (upsTestSpinLock = lock_value, upsTestId = requested_test) if (error_index == 1) { /* (upsTestSpinLock failed) */ /* if problem is not access control, then some other manager slipped in ahead of us */ goto try_again } if (error_index == 2) { /* (upsTestId) */ /* cannot perform the test */ give up } /* test started ok */ /* wait for test completion by pollingCase [Page 20]RFC 1628 UPS MIB May 1994 upsTestResultsSummary */ get (upsTestSpinLock, upsTestResultsSummary, upsTestResultsDetail) while (upsTestResultsSummary == inProgress) { short delay get (upsTestSpinLock, upsTestResultsSummary, upsTestResultsDetail) } /* when test completes, retrieve any additional test results */ /* if upsTestSpinLock == lock_value + 1, then these are our test */ /* results (as opposed to another manager's */ The initial value of upsTestSpinLock at agent initialization shall be 1." ::= { upsTest 2 } upsTestResultsSummary OBJECT-TYPE SYNTAX INTEGER { donePass(1), doneWarning(2), doneError(3), aborted(4), inProgress(5), noTestsInitiated(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of upsTestId to upsTestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results." ::= { upsTest 3 } upsTestResultsDetail OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255))Case [Page 21]RFC 1628 UPS MIB May 1994
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -