⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc1696.txt

📁 著名的RFC文档,其中有一些文档是已经翻译成中文的的.
💻 TXT
📖 第 1 页 / 共 4 页
字号:
            data after a dial sequence has been executed."    DEFVAL      { async }    ::= { mdmDTEInterfaceEntry 4 }mdmDTEInactivityTimeout OBJECT-TYPE    SYNTAX      Integer32 (0..65535)    MAX-ACCESS  read-write    STATUS      current    DESCRIPTION            "The amount of idle time in minutes that the modem will wait            before disconnecting a connection.  When a call is connected            and no data is transferred (continuous marking condition) on            both circuits 103 and 104 for the specified time, the DCE            disconnects the call. If the value is 0, no idle disconnect            will occur.  This function applies to asynchronous dial            operations only and is intended for administrative control            over idle connections."    REFERENCE   "V.58 inactivityTimerSelect"    DEFVAL { 0 }    ::= { mdmDTEInterfaceEntry 5 }-- The Call Control TableBarnes, Brown, Royston & Waldbusser                            [Page 16]RFC 1696                       Modem MIB                     August 1994mdmCallControlTable OBJECT-TYPE    SYNTAX      SEQUENCE OF MdmCallControlEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION            "The modem Call Control Table augments the modem ID table."    ::= { mdmMIBObjects 7 }mdmCallControlEntry OBJECT-TYPE    SYNTAX      MdmCallControlEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION            "Entries in this table are created only by the agent. One            entry exists for each modem managed by the agent."    AUGMENTS    { mdmIDEntry }    ::= { mdmCallControlTable 1 }MdmCallControlEntry ::= SEQUENCE {    mdmCCRingsBeforeAnswer      Integer32,    mdmCCCallSetUpFailTimer     Integer32,    mdmCCResultCodeEnable       INTEGER,    mdmCCEscapeAction           INTEGER,    mdmCCCallDuration           Integer32,    mdmCCConnectionFailReason   INTEGER}mdmCCRingsBeforeAnswer OBJECT-TYPE    SYNTAX      Integer32    MAX-ACCESS  read-write    STATUS      current    DESCRIPTION            "Determines which ring the modem will wait to answer the            phone on.  If this value is `0', the modem will not go            offhook and answer a call when a ring signal is detected."    REFERENCE   "V.58 ringsBeforeAnswer"    DEFVAL      { 1 }    ::= { mdmCallControlEntry 1 }mdmCCCallSetUpFailTimer OBJECT-TYPE    SYNTAX      Integer32 (0..255)    MAX-ACCESS  read-write    STATUS      current    DESCRIPTION            "This parameter specifies the amount of time, in seconds,            that the modem shall allow between either answering a call            (automatically or manually) or completion of dialing, and            establishment of a connection with the remote modem. If noBarnes, Brown, Royston & Waldbusser                            [Page 17]RFC 1696                       Modem MIB                     August 1994            connection is established during this time, the modem            disconnects from the line and returns a result code            indicating the cause of the disconnection. In TIA-602, this            is controlled by the value in the S7 register."    REFERENCE   "V.58 callSetUpFailTimer"    DEFVAL      { 30 }    ::= { mdmCallControlEntry 2 }mdmCCResultCodeEnable OBJECT-TYPE    SYNTAX      INTEGER {                    disabled(1),                    numericEnabled(2),                    verboseEnabled(3)                }    MAX-ACCESS  read-write    STATUS      current    DESCRIPTION            "When disabled, the DCE shall issue no 'result codes' of any            kind to the DTE either in response to unsolicited events            (eg. ring signal), or commands. In TIA-602, this is            controlled by the ATQ command.  When numericEnabled, the DCE            shall issue result codes in numeric form.  When            verboseEnabled, the DCE shall issue result codes in a            verbose, textual form."    REFERENCE   "V.58 responseModeSelect"    DEFVAL      { verboseEnabled }    ::= { mdmCallControlEntry 3 }mdmCCEscapeAction OBJECT-TYPE    SYNTAX      INTEGER {                    ignoreEscape(1),                    hangUp(2),                    enterCommandMode(3)                }    MAX-ACCESS  read-write    STATUS      current    DESCRIPTION            "The modem's action upon successfully recognizing the            'escape to command mode' character sequence."    DEFVAL { ignoreEscape }    ::= { mdmCallControlEntry 4 }-- Call status portion of the call control tablemdmCCCallDuration OBJECT-TYPE    SYNTAX      Integer32    MAX-ACCESS  read-only    STATUS      currentBarnes, Brown, Royston & Waldbusser                            [Page 18]RFC 1696                       Modem MIB                     August 1994    DESCRIPTION            "Present or last completed connection time in seconds. If            there have been no previous connections, this value should            be -1."    ::= { mdmCallControlEntry 5 }mdmCCConnectionFailReason OBJECT-TYPE    SYNTAX      INTEGER {                -- General                        unknown(1),                        other(2),                        managementCommand(3),                        inactivityTimeout(4),                        mnpIncompatibility(5),                        protocolError(6),                -- DCE                        powerLoss(10),                        equipmentFailure(11),                -- DTE Interface                        dtrDrop(20),                -- Line Interface                        noDialTone(30),                        lineBusy(31),                        noAnswer(32),                        voiceDetected(33),                -- Signal Converter                        carrierLost(40),                        trainingFailed(41),                        faxDetected(42)        }    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "Indicates the reason that the last connection or attempt            failed. The meaning of each reason code is explained below.               unknown:            This code means the failure reason is unknown or            there has been no previous call.               other:            This code used when no other code is applicable.            Additional vendor information may be available            elsewhere.               managementCommand:Barnes, Brown, Royston & Waldbusser                            [Page 19]RFC 1696                       Modem MIB                     August 1994            A management command terminated the call.  These            commands include escaping to command mode, initiating            dialing, restoring lines, and disconnecting.               inactivityTimeout:            The call was terminated because it was inactive for            at the minimum duration specified.               mnpIncompatibility:            The modems are unable to resolve MNP protocol            differences.               protocolError:            An error occured in one of protocol in use.  Further            information is required to determine in which            protocol the error occurred, and the exact nature of            the error.               powerLoss:            The modem lost power and disconnected the call.               equipmentFailure:            The modem equipment failed.               dtrDrop:            DTR has been turned off while the modem is to            disconnect on DTR drop. (Ref: V.58 cct108TurnedOff)               noDialTone:            If the modem is to monitor for call progress tones,            but the modem has failed to detect dial tone while            attempting to dial a number.               lineBusy:            Busy signal is detected while busy signal detection            is enabled, or while the 'W' or '@' dial modifier is            used. (Ref: V.58 engagedTone)               noAnswer:            The call was not answered.               voiceDetected:            A voice was detected on the call.               carrierLost:            Indicates that the modem has disconnected due to            detection of loss of carrier.  In TIA-602, the S10            register determines the time that loss of carrierBarnes, Brown, Royston & Waldbusser                            [Page 20]RFC 1696                       Modem MIB                     August 1994            must be detected before the modem disconnects.               trainingFailed:            Indicates that the modems did not successfully train            and reach data mode on the previous connection.               faxDetected:            A fax was detected on the call."    REFERENCE   "V.58 callCleared"    ::= { mdmCallControlEntry 6 }-- The Stored Dial String tablemdmCCStoredDialStringTable OBJECT-TYPE    SYNTAX      SEQUENCE OF MdmCCStoredDialStringEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION            "The table of stored dial strings."    REFERENCE   "V.58 telephoneNumbers"    ::= { mdmMIBObjects 8 }mdmCCStoredDialStringEntry OBJECT-TYPE    SYNTAX      MdmCCStoredDialStringEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION            "A stored dial string."    INDEX  { mdmIndex, mdmCCStoredDialStringIndex }    ::= { mdmCCStoredDialStringTable 1 }MdmCCStoredDialStringEntry ::= SEQUENCE {    mdmCCStoredDialStringIndex     Integer32,    mdmCCStoredDialString          DisplayString}mdmCCStoredDialStringIndex OBJECT-TYPE    SYNTAX      Integer32 (0..65535)    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION            "The unique index of a particular dial string."    ::= { mdmCCStoredDialStringEntry 1 }mdmCCStoredDialString OBJECT-TYPE    SYNTAX      DisplayString (SIZE(0..64))    MAX-ACCESS  read-write    STATUS      currentBarnes, Brown, Royston & Waldbusser                            [Page 21]RFC 1696                       Modem MIB                     August 1994    DESCRIPTION            "A dial string stored in the modem."    ::= { mdmCCStoredDialStringEntry 2 }-- The modem Error Correcting GroupmdmECTable OBJECT-TYPE    SYNTAX      SEQUENCE OF MdmECEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION            "The modem error correcting table augments the modem ID            table."    ::= { mdmMIBObjects 9 }mdmECEntry OBJECT-TYPE    SYNTAX      MdmECEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION            "Entries in this table are created only by the agent. One            entry exists for each modem managed by the agent."    AUGMENTS    { mdmIDEntry }    ::= { mdmECTable 1 }MdmECEntry ::= SEQUENCE {    mdmECErrorControlUsed           OBJECT IDENTIFIER}mdmECErrorControlUsed OBJECT-TYPE    SYNTAX      OBJECT IDENTIFIER    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "Indicates the error control method used during the current            or previous call.  This shall be one of the values for error            control protocols registered in the capabilities table for            this modem.  If no error control protocol is in use, this            object shall have the value '{0 0}'."    REFERENCE   "V.58 errorControlActive"    ::= { mdmECEntry 1 }-- The modem Data Compression GroupmdmDCTable OBJECT-TYPE    SYNTAX      SEQUENCE OF MdmDCEntry    MAX-ACCESS  not-accessible    STATUS      currentBarnes, Brown, Royston & Waldbusser                            [Page 22]RFC 1696                       Modem MIB                     August 1994    DESCRIPTION            "The modem data compression table augments the modem ID            table."    ::= { mdmMIBObjects 10 }mdmDCEntry OBJECT-TYPE    SYNTAX      MdmDCEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION            "Entries in this table are created only by the agent. One            entry exists for each modem managed by the agent."    AUGMENTS    { mdmIDEntry }    ::= { mdmDCTable 1 }MdmDCEntry ::= SEQUENCE {    mdmDCCompressionTypeUsed        OBJECT IDENTIFIER}mdmDCCompressionTypeUsed OBJECT-TYPE    SYNTAX      OBJECT IDENTIFIER    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "Indicates the data compression method used during the            current or previous call.  This shall be one of the values            for compression protocols registered in the capabilities            table for this modem.  If no compression protocol is in use,            this object shall have the value '{0 0}'."    ::= { mdmDCEntry 1 }-- The modem Signal Convertor GroupmdmSCTable OBJECT-TYPE    SYNTAX      SEQUENCE OF MdmSCEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION            "The modem signal convertor table augments the modem ID            table."    ::= { mdmMIBObjects 11 }mdmSCEntry OBJECT-TYPE    SYNTAX      MdmSCEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION            "Entries in this table are created only by the agent. OneBarnes, Brown, Royston & Waldbusser                            [Page 23]RFC 1696                       Modem MIB                     August 1994            entry exists for each modem managed by the agent."    AUGMENTS    { mdmIDEntry }    ::= { mdmSCTable 1 }MdmSCEntry ::= SEQUENCE {    mdmSCCurrentLineTransmitRate        Integer32,    mdmSCCurrentLineReceiveRate         Integer32,    mdmSCInitialLineTransmitRate        Integer32,    mdmSCInitialLineReceiveRate         Integer32,    mdmSCModulationSchemeUsed           OBJECT IDENTIFIER}

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -