📄 rfc1285.txt
字号:
REFERENCE "ANSI { fddiMAC 14 }" ::= { snmpFddiMACEntry 5 } snmpFddiMACPathsAvailable OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A value that indicates the PATH types available for this MAC. The value is a sum. This value initially takes the value zero, then for each type of PATH that this MAC has available, 2 raised to a power is added to the sum. The powers are according to the following table: Path Power Primary 0 Secondary 1 Local 2 " REFERENCE "ANSI { fddiMAC 22 }" ::= { snmpFddiMACEntry 6 } snmpFddiMACCurrentPath OBJECT-TYPE SYNTAX INTEGER { unknown(1), primary(2), secondary(4), local(8), isolated(16) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the association of the MAC with a station PATH." REFERENCE "ANSI { fddiMAC 23 }" ::= { snmpFddiMACEntry 7 } snmpFddiMACUpstreamNbr OBJECT-TYPE SYNTAX FddiMACLongAddressType -- OCTET STRING (SIZE (6))Case [Page 19]RFC 1285 FDDI MIB January 1992 ACCESS read-only STATUS mandatory DESCRIPTION "The MAC's upstream neighbor's long individual MAC address. It may be determined by the Neighbor Information Frame protocol (refer to ANSI SMT 7.2.1). The value shall be reported as '00 00 00 00 00 00' if it is unknown." REFERENCE "ANSI { fddiMAC 24 }" ::= { snmpFddiMACEntry 8 } snmpFddiMACOldUpstreamNbr OBJECT-TYPE SYNTAX FddiMACLongAddressType -- OCTET STRING (SIZE (6)) ACCESS read-only STATUS mandatory DESCRIPTION "The previous value of the MAC's upstream neighbor's long individual MAC address. It may be determined by the Neighbor Information Frame protocol (refer to ANSI SMT 7.2.1). The value shall be reported as '00 00 00 00 00 00' if it is unknown." REFERENCE "ANSI { fddiMAC 26 }" ::= { snmpFddiMACEntry 9 } snmpFddiMACDupAddrTest OBJECT-TYPE SYNTAX INTEGER { none(1), pass(2), fail(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The Duplicate Address Test flag, Dup_Addr_Test (refer to ANSI 8.3.1)." REFERENCE "ANSI { fddiMAC 29 }" ::= { snmpFddiMACEntry 10 } snmpFddiMACPathsRequested OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A value that indicates PATH(s) desired for this MAC. The value is a sum which represents the individual PATHs that are desired. This value initiallyCase [Page 20]RFC 1285 FDDI MIB January 1992 takes the value zero, then for each type of PATH that this node is, 2 raised to a power is added to the sum. The powers are according to the following table: Path Power Primary 0 Secondary 1 Local 2 Isolated 3 The precedence order is primary, secondary, local, and then isolated if multiple PATHs are desired are set." REFERENCE "ANSI { fddiMAC 32 }" ::= { snmpFddiMACEntry 11 } snmpFddiMACDownstreamPORTType OBJECT-TYPE SYNTAX INTEGER { a(1), b(2), s(3), m(4), unknown(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the PC-Type of the first port that is downstream of this MAC (the exit port)." REFERENCE "ANSI { fddiMAC 33 }" ::= { snmpFddiMACEntry 12 } snmpFddiMACSMTAddress OBJECT-TYPE SYNTAX FddiMACLongAddressType -- OCTET STRING (SIZE (6)) ACCESS read-only STATUS mandatory DESCRIPTION "The 48 bit individual address of the MAC used for SMT frames." REFERENCE "ANSI { fddiMAC 41 }" ::= { snmpFddiMACEntry 13 } snmpFddiMACTReq OBJECT-TYPE SYNTAX FddiTime ACCESS read-write STATUS mandatory DESCRIPTION "The value of T-Req (refer to ANSI MAC 2.2.1 and ANSI MAC 7.3.5.2)." REFERENCECase [Page 21]RFC 1285 FDDI MIB January 1992 "ANSI { fddiMAC 51 }" ::= { snmpFddiMACEntry 14 } snmpFddiMACTNeg OBJECT-TYPE SYNTAX FddiTime ACCESS read-only STATUS mandatory DESCRIPTION "The value of T-Neg (refer to ANSI MAC 2.2.1 and ANSI MAC 7.3.5.2)." REFERENCE "ANSI { fddiMAC 52 }" ::= { snmpFddiMACEntry 15 } snmpFddiMACTMax OBJECT-TYPE SYNTAX FddiTime ACCESS read-only STATUS mandatory DESCRIPTION "The value of T-Max (refer to ANSI MAC 2.2.1 and ANSI MAC 7.3.5.2)." REFERENCE "ANSI { fddiMAC 53 }" ::= { snmpFddiMACEntry 16 } snmpFddiMACTvxValue OBJECT-TYPE SYNTAX FddiTime ACCESS read-only STATUS mandatory DESCRIPTION "The value of TvxValue (refer to ANSI MAC 2.2.1 and ANSI MAC 7.3.5.2)." REFERENCE "ANSI { fddiMAC 54 }" ::= { snmpFddiMACEntry 17 } snmpFddiMACTMin OBJECT-TYPE SYNTAX FddiTime ACCESS read-only STATUS mandatory DESCRIPTION "The value of T-Min (refer to ANSI MAC 2.2.1 and ANSI MAC 7.3.5.2)." REFERENCE "ANSI { fddiMAC 55 }" ::= { snmpFddiMACEntry 18 }Case [Page 22]RFC 1285 FDDI MIB January 1992 snmpFddiMACCurrentFrameStatus OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-write STATUS mandatory DESCRIPTION "A value that indicates the MAC's operational frame status setting functionality. The value is a sum. This value initially takes the value zero, then for each functionality present, 2 raised to a power is added to the sum. The powers are according to the following table: Functionality Power FSC-Type0 0 -- MAC repeats A/C indicators as received FSC-Type1 1 -- MAC sets C but not A on copying for -- forwarding FSC-Type2 2 -- MAC resets C and sets A on C set and A -- reset if frame is not copied " REFERENCE "ANSI { fddiMAC 63 }" ::= { snmpFddiMACEntry 19 } snmpFddiMACFrameCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame_Ct (refer to ANSI MAC 2.2.1)." REFERENCE "ANSI { fddiMAC 71 }" ::= { snmpFddiMACEntry 20 } snmpFddiMACErrorCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Error_Ct (refer to ANSI MAC 2.2.1)." REFERENCE "ANSI { fddiMAC 81 }" ::= { snmpFddiMACEntry 21 }Case [Page 23]RFC 1285 FDDI MIB January 1992 snmpFddiMACLostCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Lost_Ct (refer to ANSI MAC 2.2.1)." REFERENCE "ANSI { fddiMAC 82 }" ::= { snmpFddiMACEntry 22 } snmpFddiMACFrameErrorThreshold OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A threshold for determining when a MAC Condition report should be generated. The condition is true when the ratio, ((delta snmpFddiMACLostCt + delta snmpFddiMACErrorCt) / (delta snmpFddiMACFrameCt + delta snmpFddiMACLostCt)) x 2**16. exceeds the threshold. It is used to determine when a station has an unacceptable frame error threshold. The sampling algorithm is implementation dependent. Any attempt to set this variable to a value of less than one shall result in a badValue error. Those who are familiar with the SNMP management framework will recognize that thresholds are not in keeping with the SNMP philosophy. However, this variable is supported by underlying SMT implementations already and maintaining this threshold should not pose an undue additional burden on SNMP agent implementors." REFERENCE "ANSI { fddiMAC 95 }" ::= { snmpFddiMACEntry 23 } snmpFddiMACFrameErrorRatio OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute is the actual ratio, ((delta snmpFddiMACLostCt + delta snmpFddiMACErrorCt) / (delta snmpFddiMACFrameCt + delta snmpFddiMACLostCt)) x 2**16." REFERENCE "ANSI { fddiMAC 96 }" ::= { snmpFddiMACEntry 24 }Case [Page 24]RFC 1285 FDDI MIB January 1992 snmpFddiMACRMTState OBJECT-TYPE SYNTAX INTEGER { rm0(1), -- Isolated rm1(2), -- Non_Op rm2(3), -- Ring_Op rm3(4), -- Detect
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -