📄 rfc1271.txt
字号:
etherHistoryBroadcastPkts Counter, etherHistoryMulticastPkts Counter, etherHistoryCRCAlignErrors Counter, etherHistoryUndersizePkts Counter, etherHistoryOversizePkts Counter, etherHistoryFragments Counter, etherHistoryJabbers Counter, etherHistoryCollisions Counter, etherHistoryUtilization INTEGER (0..10000) } etherHistoryIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The history of which this entry is a part. The history identified by a particular value of this index is the same history as identified by the same value of historyControlIndex." ::= { etherHistoryEntry 1 }Remote Network Monitoring Working Group [Page 23]RFC 1271 Remote Network Monitoring MIB November 1991 etherHistorySampleIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies the particular sample this entry represents among all samples associated with the same historyControlEntry. This index starts at 1 and increases by one as each new sample is taken." ::= { etherHistoryEntry 2 } etherHistoryIntervalStart OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime at the start of the interval over which this sample was measured. If the probe keeps track of the time of day, it should start the first sample of the history at a time such that when the next hour of the day begins, a sample is started at that instant. Note that following this rule may require the probe to delay collecting the first sample of the history, as each sample must be of the same interval. Also note that the sample which is currently being collected is not accessible in this table until the end of its interval." ::= { etherHistoryEntry 3 } etherHistoryDropEvents OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of events in which packets were dropped by the probe due to lack of resources during this interval. Note that this number is not necessarily the number of packets dropped, it is just the number of times this condition has been detected." ::= { etherHistoryEntry 4 } etherHistoryOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets of data (includingRemote Network Monitoring Working Group [Page 24]RFC 1271 Remote Network Monitoring MIB November 1991 those in bad packets) received on the network (excluding framing bits but including FCS octets)." ::= { etherHistoryEntry 5 } etherHistoryPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets (including error packets) received during this sampling interval." ::= { etherHistoryEntry 6 } etherHistoryBroadcastPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of good packets received during this sampling interval that were directed to the broadcast address." ::= { etherHistoryEntry 7 } etherHistoryMulticastPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of good packets received during this sampling interval that were directed to a multicast address. Note that this number does not include packets addressed to the broadcast address." ::= { etherHistoryEntry 8 } etherHistoryCRCAlignErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets received during this sampling interval that had a length (excluding framing bits but including FCS octets) between 64 and 1518 octets, inclusive, but were not an integral number of octets in length or had a bad Frame Check Sequence (FCS)." ::= { etherHistoryEntry 9 }Remote Network Monitoring Working Group [Page 25]RFC 1271 Remote Network Monitoring MIB November 1991 etherHistoryUndersizePkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets received during this interval that were less than 64 octets long (excluding framing bits but including FCS octets) and were otherwise well formed." ::= { etherHistoryEntry 10 } etherHistoryOversizePkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets received during this interval that were longer than 1518 octets (excluding framing bits but including FCS octets) but were otherwise well formed." ::= { etherHistoryEntry 11 } etherHistoryFragments OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of packets received during this sampling interval that were not an integral number of octets in length or that had a bad Frame Check Sequence (FCS), and were less than 64 octets in length (excluding framing bits but including FCS octets)." ::= { etherHistoryEntry 12 } etherHistoryJabbers OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets received during this interval that were longer than 1518 octets (excluding framing bits but including FCS octets), and were not an integral number of octets in length or had a bad Frame Check Sequence (FCS)." ::= { etherHistoryEntry 13 }Remote Network Monitoring Working Group [Page 26]RFC 1271 Remote Network Monitoring MIB November 1991 etherHistoryCollisions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The best estimate of the total number of collisions on this Ethernet segment during this interval." ::= { etherHistoryEntry 14 } etherHistoryUtilization OBJECT-TYPE SYNTAX INTEGER (0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "The best estimate of the mean physical layer network utilization on this interface during this interval, in hundredths of a percent." ::= { etherHistoryEntry 15 } -- The Alarm Group -- Implementation of the Alarm group is optional. -- -- The Alarm Group requires the implementation of the Event -- group. -- -- The Alarm group periodically takes statistical samples from -- variables in the probe and compares them to thresholds -- that have been configured. The alarm table stores -- configuration entries that each define a variable, -- polling period, and threshold parameters. If a sample is -- found to cross the threshold values, an event is -- generated. Only variables that resolve to an ASN.1 -- primitive type of INTEGER (INTEGER, Counter, -- Gauge, or TimeTicks) may be monitored in this way. -- -- This function has a hysteresis mechanism to limit the -- generation of events. This mechanism generates one event -- as a threshold is crossed in the appropriate direction. -- No more events are generated for that threshold until the -- opposite threshold is crossed. -- -- In the case of a sampling a deltaValue, a probe may -- implement this mechanism with more precision if it takes -- a delta sample twice per period, each time comparing the -- sum of the latest two samples to the threshold. This -- allows the detection of threshold crossingsRemote Network Monitoring Working Group [Page 27]RFC 1271 Remote Network Monitoring MIB November 1991 -- that span the sampling boundary. Note that this does not -- require any special configuration of the threshold value. -- It is suggested that probes implement this more precise -- algorithm. alarmTable OBJECT-TYPE SYNTAX SEQUENCE OF AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of alarm entries." ::= { alarm 1 } alarmEntry OBJECT-TYPE SYNTAX AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of parameters that set up a periodic checking for alarm conditions." INDEX { alarmIndex } ::= { alarmTable 1 } AlarmEntry ::= SEQUENCE { alarmIndex INTEGER (1..65535), alarmInterval INTEGER, alarmVariable OBJECT IDENTIFIER, alarmSampleType INTEGER, alarmValue INTEGER, alarmStartupAlarm INTEGER, alarmRisingThreshold INTEGER, alarmFallingThreshold INTEGER, alarmRisingEventIndex INTEGER (1..65535), alarmFallingEventIndex INTEGER (1..65535), alarmOwner OwnerString, alarmStatus INTEGER } alarmIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies an entry in the alarm table. Each such entry defines a diagnostic sample at a particular interval for an object on the device." ::= { alarmEntry 1 }Remote Network Monitoring Working Group [Page 28]RFC 1271 Remote Network Monitoring MIB November 1991 alarmInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -